10-11-2010, 04:04 PM
Thread: NEW TRANE AIR HANDLER SWEATING
by super_tech_1- Replies
- 27
- Views
- 2,359
no you posted a product information data sheet...
no you posted a product information data sheet that is not an installation guide. Look up long line applications if it isn't in your instal guide you should be able to get it from trane
-
10-09-2010, 02:48 PM
Thread: HVAC Advice
by super_tech_1- Replies
- 17
- Views
- 1,272
I suggest you go with the one you trust the most...
I suggest you go with the one you trust the most and has a good reputation. As long as that guy aint the one who wanted to put in a 2.5 ton or couldn't tell what size the air handler was its right...
-
10-09-2010, 02:34 PM
Thread: NEW TRANE AIR HANDLER SWEATING
by super_tech_1- Replies
- 27
- Views
- 2,359
you should try reading an installtion guide...
you should try reading an installtion guide sometime if you cant do that try hooked on phonics. Long line application start at 60 ft. The difference in charge is not pounds but ounces per additional...
-
10-09-2010, 02:30 PM
Thread: Apartment central ac question
by super_tech_1- Replies
- 9
- Views
- 1,318
Usually if you have a problem and you have to...
Usually if you have a problem and you have to call a service tech then the bill is subtracted from your rent. This can cause alot of arguing depending on your landlord or it could be no problem I...
-
09-28-2010, 12:07 AM
Thread: Apartment central ac question
by super_tech_1- Replies
- 9
- Views
- 1,318
You need maintenance. your talking about 30 or so...
You need maintenance. your talking about 30 or so degree temp difference this happens when you don't have enough air flow. You probably need a good coil cleaning blower wheel cleaning and filter...
-
09-27-2010, 04:56 PM
- Replies
- 13
- Views
- 1,487
Rheem 16 seer throw in a thermostat and a 1 year...
Rheem 16 seer throw in a thermostat and a 1 year maintenance agreement
-
09-27-2010, 04:52 PM
Thread: NEW TRANE AIR HANDLER SWEATING
by super_tech_1- Replies
- 27
- Views
- 2,359
Unless you have copper pipes 60 feet in length or...
Unless you have copper pipes 60 feet in length or more you shouldn't need to add refrigerant. In addition the amount you will add is quite small ounces not pounds. knowing boca I doubt you have 60...
-
05-04-2009, 10:22 PM
Thread: Why the condensate drain trap?
by super_tech_1- Replies
- 11
- Views
- 18,827
to allow the water to drain with out it air...
to allow the water to drain with out it air flowing in the drain line can cause the water to not flow
-
04-30-2009, 12:16 AM
Thread: Change Refrigrant?
by super_tech_1- Replies
- 3
- Views
- 359
change the lines.
change the lines.
-
04-30-2009, 12:10 AM
- Replies
- 20
- Views
- 1,096
so your going to have eight different airhandlers...
so your going to have eight different airhandlers to maintain and fix by techs that have no idea how to work with these things. I say yeah go for it whats the worst that could happen
-
04-28-2009, 09:48 PM
Thread: Thermostat Question
by super_tech_1- Replies
- 3
- Views
- 383
honeywell 8000 touchscreen
honeywell 8000 touchscreen
-
04-28-2009, 09:07 PM
- Replies
- 8
- Views
- 562
They don't want the truth they want you to tell...
They don't want the truth they want you to tell them what they want to hear. She'll just call someone else until she gets what she wants
-
04-22-2009, 10:03 PM
- Replies
- 32
- Views
- 2,754
yeah both your thoughts will help with out seeing...
yeah both your thoughts will help with out seeing the house i can only answere theoreticly.
-
04-22-2009, 09:41 PM
Thread: R22 now - R410a in the future
by super_tech_1- Replies
- 26
- Views
- 4,230
This is something you should concern your self...
This is something you should concern your self with. No it's not a good practice to run r410a through a r22 coil. This hot shot 22 is not approved to operate in any manufactures equipment that i...
-
04-16-2009, 10:58 PM
- Replies
- 3
- Views
- 385
Theres nothing wrong with ruud the only thing i...
Theres nothing wrong with ruud the only thing i hate is the installers like to leave the little foam thing they call a filter. I would have my guy include a media filter that mounts to the...
-
04-16-2009, 10:48 PM
- Replies
- 33
- Views
- 2,562
why are you using a humidistat. There are...
why are you using a humidistat. There are hundreds of new thermostats that also control humidity all in one. I had trouble following what you were saying but it sounds right I believe what your...
-
04-16-2009, 10:40 PM
Thread: Swapping heat pumps but not A-coil
by super_tech_1- Replies
- 5
- Views
- 348
when meeting with the service guys the one that...
when meeting with the service guys the one that tells you no he's the guy you want the one's that tell you yes we can do that don't hire them.
-
04-16-2009, 10:33 PM
Thread: furnace filter question
by super_tech_1- Replies
- 8
- Views
- 595
as a tech we prefer you use the fiberglass...
as a tech we prefer you use the fiberglass filters so we can fix your equipment more often. It's profitable for us. However if you want to protect your investment then use the pleated filters. If you...
-
04-16-2009, 07:50 PM
Thread: duel run capacitor
by super_tech_1- Replies
- 10
- Views
- 567
It's not going to kill it your fine however the...
It's not going to kill it your fine however the guy that said what happens when the next guy changes it is right however I would really worry about you if your changing the same cap that often.
-
12-23-2008, 02:18 PM
Thread: wwpd ?
by super_tech_1- Replies
- 8
- Views
- 420
Just do the 80% furnace. It will be more efficent...
Just do the 80% furnace. It will be more efficent then what you have with none of the problems. I would also consider doing a heat pump if you aren't already going that rought. The difference between...
-
12-05-2008, 10:04 PM
Thread: The best mini split heat pump
by super_tech_1- Replies
- 8
- Views
- 5,300
if their hvac is anything like the lg phone i...
if their hvac is anything like the lg phone i used to have then I would say lg however i know mitzu is very good stuff so I'm going to vote mitzu
-
12-05-2008, 10:00 PM
- Replies
- 9
- Views
- 2,438
1.)do not jump or disconnect anything. I'm...
1.)do not jump or disconnect anything.
I'm assuming by what bald loonie said thats an infinity furnace. The reason he would suggest this is because It gives you the capabilities to operate your... -
12-05-2008, 09:39 PM
Thread: New Furnace question
by super_tech_1- Replies
- 23
- Views
- 3,401
If the duct is to big I would tell you to go with...
If the duct is to big I would tell you to go with the variable speed. Plus it gives more comfort. On the other hand you've always had single speed so it's not like your loosing anything. Variable...
-
12-05-2008, 09:28 PM
- Replies
- 16
- Views
- 745
I think it was beenthere who does those figures...
I think it was beenthere who does those figures all the time in my area im lucky to get to play with a gas furnace so we don't spend much time doin figures like that. see if you cant track him down...
-
12-04-2008, 09:41 PM
Thread: XP19 Defrosting Unnecessarily
by super_tech_1- Replies
- 19
- Views
- 852
Somethings not right with what you said when that...
Somethings not right with what you said when that thing goes into defrost you should be heating in gas. I believe with out making a phone call the furnace you mentioned has a heat rise somewhere...