  1. Replies
    8
    Views
    860

    Yep we have had failures too. I have them stop...

    Yep we have had failures too. I have them stop driving after being installed for a few months(only to drive again normal after a power cycle), I have had them drive 10-0 no matter where the switch is...
  2. Thread: Spyder VVT Logic

    by MDaly
    Replies
    5
    Views
    439

    I did one. Very simple program per-say, My...

    I did one. Very simple program per-say, My program has heat cool and fan only. when in between heat or cool unit is in fan only mode and zone dampers go to 50%. I pass only terminal mode from zones...
  3. Replies
    7
    Views
    1,218

    I think this is John talking to fast, He never...

    I think this is John talking to fast, He never does that right,. LOL


    Here is why I say.
    If, then you would be in full heat at Setpoint and wouldn't get to start cooling until sensor =...
  4. Replies
    21
    Views
    2,273

    Spyder

    Also take care to know which Rev controller you have, look for a side ways 2 on the sticker next to the part number on the side. If this is there then you may need to flash it back to work with your...
  5. Replies
    15
    Views
    2,823

    Yeah that was some great stuff. Let the genie out...

    Yeah that was some great stuff. Let the genie out of the jar baby, lol. I was all over the ASC for VAV's and CAV's until I saw that new Venom.

    Is it here yet? Is it here Yet? How about now? Now?...
  6. Thread: AX Lon Links

    by MDaly
    Replies
    5
    Views
    479

    Any proxy linked points would be gone. for...

    Any proxy linked points would be gone. for example let's say you link OSA from one controller to another but do it from proxy points under the point folder to proxy points under another devices point...
  7. Replies
    6
    Views
    795

    I did something like this with the trend service....

    I did something like this with the trend service. Not so realtize as much but more of a copy find replace and past though, worked great.
  8. Replies
    95
    Views
    4,852

    I concur, most all my programing is done in the...

    I concur, most all my programing is done in the field controller. I do have some exception you did not list though.

    1. AHU supply resets as-well as some other resets depending on the job. Because...
  9. Replies
    13
    Views
    1,593

    MatrixTransform, That was great and I thought...

    MatrixTransform, That was great and I thought Invensys was "No" happy. I am so glad I got out from under the BC/Siebe/Invensys/Schneider/"add soon to be new name here".
    The first two years after I...
  10. Replies
    127
    Views
    6,395

    Oh also forgot something very important that was...

    Oh also forgot something very important that was told to me.

    "Marriage is about Love Divorce is about business. Don't let love screw up the business, just because business screwed up the love."
    ...
  11. Replies
    127
    Views
    6,395

    I went through this last year. It was a little...

    I went through this last year. It was a little different but all the same in the end. Life is great now. I just moved into a new place (to many old ghosts at the old place). I have my kids one week...
  12. The cost of living in Los Angeles, CA (just an...

    The cost of living in Los Angeles, CA (just an example) is 62.8% higher than in Dayton, OH . Therefore, you would have to earn a salary of $105,840 to maintain your current standard of living (if you...
  13. 50K-$65K A year? That seams like more...

    50K-$65K A year? [/QUOTE]

    That seams like more of a Controls Operation Manager position than a Control specialist.
    Are the wages in Ohio really that much less then here in Cali? That Job would...
  14. Replies
    7
    Views
    626

    I see both being used. With Honeywell we can use...

    I see both being used. With Honeywell we can use either for our field controllers. MOst of the time we use LON. I have a big job right now where we are useing LON for over 90% and BacNet for the...
  15. Thread: Network 8000

    by MDaly
    Replies
    13
    Views
    1,315

    I cut my teeth on Network 8000 and IMHO it's a...

    I cut my teeth on Network 8000 and IMHO it's a great system. One thing I really miss is the OSS block. It was a very simple and effective use of Optimal Start Stop. One block did it all.

    If I were...
  16. Thread: Network 8000

    by MDaly
    Replies
    13
    Views
    1,315

    the green plug is most likely the RS-485 ASD...

    the green plug is most likely the RS-485 ASD connector. There are two ways to connect a Jace to a Network 8000 system.
    1, The wam bam thank you mam way use a 9 to 9 pin Rs-232 cable and connect...
  17. Thread: Network 8000

    by MDaly
    Replies
    13
    Views
    1,315

    There should have ben no need to mess with the...

    There should have ben no need to mess with the buss. They should have just disconected the ASD from the GCM and connect it to the Jace.


    No and yes. There are many sites that have run for years...
  18. Thread: Network 8000

    by MDaly
    Replies
    13
    Views
    1,315

    Just to make sure, when you replaced the 14...

    Just to make sure, when you replaced the 14 MicroNets did you make sure you set the adresses?
    Did you verify the addresses are corect and match the Micronets in the MNFLO blocks in the GCM? Address...
  19. Thread: Bacnet spyder

    by MDaly
    Replies
    12
    Views
    1,709

    I just got done with the first phase of a small...

    I just got done with the first phase of a small BACnet Spyder job.
    This phase was an unoccupied remodel that used 12 Spyders (1 AHU, CP, and 9 VAV's) and 7 Viconics BACnet Fan Coil Thermostats. All...
  20. Thread: Workplace Pro

    by MDaly
    Replies
    9
    Views
    1,436

    The other thing you will need is a new Jace...

    The other thing you will need is a new Jace license with your ORG id or you will not be able to access it with your copy of Workplace Pro.
  21. Thread: Idiot sightings

    by MDaly
    Replies
    17
    Views
    2,674

    Years ago when I was at a friends house during...

    Years ago when I was at a friends house during our band practice there was a power outage. So we all sat around drinking beer waiting for the power to come on. After a while we all started noticing...
  22. Replies
    11
    Views
    951

    You could always add sump heaters to your tower.

    You could always add sump heaters to your tower.
  23. Replies
    4
    Views
    401

    Did you move the .bmp's over there also or just...

    Did you move the .bmp's over there also or just the .ssf's?
  24. Replies
    5
    Views
    812

    Spyders are nice, but I like the simplicity of...

    Spyders are nice, but I like the simplicity of the Smart VAV. With the Spyder S series you can use the new TR70 which is nice because you only have to run 1 cable to get a ton of information from the...
  25. Replies
    24
    Views
    7,691

    I'm hearing phase out but with continued support....

    I'm hearing phase out but with continued support. No new IA jobs, Phase out of Invensys control line. It's all suppose to Start happening around Aug. Sept. this year. That's just the rumors I'm...