    Any feedback on one of your original questions?...

    Any feedback on one of your original questions? Have you checked the capacity of the new compressor to the size of the system?
  2. The subcooling specs are usually listed on the...

    The subcooling specs are usually listed on the unit information sticker. Or by using the charging chart/checking the charge chart found on the unit you will be able to figure out the proper...
  3. Replies
    5
    Views
    802

    I had one a few months ago, it had a spun copper...

    I had one a few months ago, it had a spun copper LL drier (coming off of the condenser) brazed into a check valve. And off of one of the lines from the evap it just had a check valve.

    I...
  4. Replies
    6
    Views
    446

    [QUOTE=aaronmccann;10688622]The original install...

    [QUOTE=aaronmccann;10688622]The original install company is refusing to believe there is a problem and has not came back to check his installation. I told him what the issue was and he said that...
  5. Replies
    7
    Views
    2,169

    I have had on some later 90's model tranes, a fan...

    I have had on some later 90's model tranes, a fan failure switch go bad or bad connections, and this would cause a failure in the heating mode. These ones are a snap disc type, spdt, and located in...
  6. Replies
    8
    Views
    2,048

    Did I say that!

    Did I say that!
  7. Replies
    8
    Views
    2,048

    I've had a couple bad rv's with those symtoms....

    I've had a couple bad rv's with those symtoms. But that doesn't explain the hot condenser. You may want to look into the causes of that. Good luck. They're really not too bad to work on. :grin2:
  8. Replies
    8
    Views
    2,048

    What makes you say the reversing valve is leaking...

    What makes you say the reversing valve is leaking by? The condenser being hot is not an indication of that.
    The condenser shouldn't be hot on a wshp, that would be a water flow or heat...
  9. Replies
    8
    Views
    627

    You need to check the required superheat based on...

    You need to check the required superheat based on the mfg charging chart. Based on the info you provided your condenser coils may be dirty enough to cause your problems. Any regular maintenance...
  10. Thread: Bad TXV?

    by ewwilt
    Replies
    10
    Views
    1,680

    Txv sounds like the culprit, but If this system...

    Txv sounds like the culprit, but If this system has a filter drier need to check that it's not restricting. :.02:
  11. Replies
    33
    Views
    6,920

    I relpaced a txv Friday (brass stubs to copper...

    I relpaced a txv Friday (brass stubs to copper lines). I used the safety silv 56 with the orange flux coating, used a wet rag also sprayed with cool jel and wrapped the txv well with it. That ss 56...
  12. Replies
    4
    Views
    1,513

    Was that brazed off on the eq line? Wouldn't it...

    Was that brazed off on the eq line? Wouldn't it slightly underfeed?
  13. Replies
    41
    Views
    2,956

    I seriously don't think Utchuck was implying...

    I seriously don't think Utchuck was implying getting a policy to cover equipment and expecting a hand out! He DId mention "getting a home warranty to cover it and the rest of my appliances that...
  14. Replies
    12
    Views
    4,065

    As I said mine looks like a carrier side by side....

    As I said mine looks like a carrier side by side. Ultimately it makes a difference on the quality of installation. Yes the arco is priced cheaper, but if you go with the cheapest labor and/or...
  15. Replies
    12
    Views
    4,065

    I replaced a carrier a/c with an arcoaire heat...

    I replaced a carrier a/c with an arcoaire heat pump in our home last fall. I am happy with its performance. Side by side the arcoaire looks like a carrier. At least the model that I bought. I have...
  16. Thread: Bad TXV??

    by ewwilt
    Replies
    43
    Views
    2,929

    If your LL truly is frosting up, filter drier may...

    If your LL truly is frosting up, filter drier may be restricting, LL solenoid problems if it has one, or LL maybe pinched somewhere.
  17. Thread: Bad TXV??

    by ewwilt
    Replies
    43
    Views
    2,929

    you could pull the bulb, warm it up (warm rag),...

    you could pull the bulb, warm it up (warm rag), and see if your suction pressure rises. This may indicate a weak bulb. And again, do your checks with nothing frosted up. You should be able to tell...
  18. Thread: Bad TXV??

    by ewwilt
    Replies
    43
    Views
    2,929

    From the info you provided, it doesn't sound like...

    From the info you provided, it doesn't sound like non-condensibles, or that it was low on charge. With the added refrigerant the best route would be to recover all of the ref. You are going to have...
  19. Replies
    63
    Views
    4,513

    [QUOTE=hvacrmedic;10289912]TXV systems cannot be...

    [QUOTE=hvacrmedic;10289912]TXV systems cannot be charged by the SH method. Most are charged by the subcooling method and some (Lennox units in particular) use the approach method.

    I have...
  20. Thread: broken ac

    by ewwilt
    Replies
    12
    Views
    1,164

    Good Advice Shophound. Thats why you're on the...

    Good Advice Shophound. Thats why you're on the edgemacation commitee. Being a little green in the field, I did'nt think about that, but it makes sense. I knew the symptoms and causes, but that will...
  21. :putergreet: tigerdunes I...

    :putergreet: tigerdunes

    I installed my heat pump last fall, it does not have this electronic demand defrost. It has a defrost board and set on 90 minutes. Based on the frost build...
  22. Replies
    63
    Views
    4,513

    The txv meters the refrigerant to the evap based...

    The txv meters the refrigerant to the evap based on the suction line temperture/bulb pressure and the evaporator pressure. The txv will meter the refrig to maintain 10 deg superheat and this keeps...
  23. I have a 2.5 ton heat pump and propane as...

    I have a 2.5 ton heat pump and propane as secondary. Our air handler is two stage gas fired. When our heat pump goes into defrost the low stage heat comes on. This low stage heat is technically not...
  24. Replies
    63
    Views
    4,513

    I agree with Suter. You wouldn't be able to...

    I agree with Suter. You wouldn't be able to accurately check the charge on a txv system using superheat. Depending on the charge in the unit and the ambient conditions the superheat may look normal...
  25. Thread: broken ac

    by ewwilt
    Replies
    12
    Views
    1,164

    Check that your indoor fan comes on when your...

    Check that your indoor fan comes on when your t-stat calls for cooling. You also need to get a look at that evaporator.