  1. Replies
    4
    Views
    1,278

    The oil case gasket is too thin and flattens out...

    The oil case gasket is too thin and flattens out with age, causing a leak. Quicker if the pump gets hot running all night on new installs. Easy and cheap repair.
  2. Put on the biggest rubber gauge condoms that fit...

    Put on the biggest rubber gauge condoms that fit and remove the stupid screens on the hose connections. They are very difficult to clean and will royally mess with you as they slowly restrict the...
  3. Replies
    16
    Views
    5,323

    I saw my first last week. The equalizer was...

    I saw my first last week. The equalizer was leaking bad enough to cause oil failures on a 130hp compressor rack 300 ft away. Just a little 1/2 ton Sporlan in a meat service case.
  4. Replies
    17
    Views
    988

    Sure, but it's 100x the cost.

    Sure, but it's 100x the cost.
  5. That's what happens with an 'in-house' refurb...

    That's what happens with an 'in-house' refurb shop for a national chain, because you know actual technicians are way too expensive.
  6. That's exactly what happened. Water was running...

    That's exactly what happened. Water was running from the trailer when they dropped it off.
  7. Replies
    5
    Views
    411

    Take 507 and add 1% R134a and now you have R404a....

    Take 507 and add 1% R134a and now you have R404a. Not much difference. R404a is just a bastard blend to get away from the R507 patent.
  8. I installed a refurbished coffin freezer, years...

    I installed a refurbished coffin freezer, years ago, that included new paint. The evap coil was still half frozen solid from a plugged drain and with the water logged insulation it weighed a good...
  9. Replies
    19
    Views
    840

    Try to get on with Jones or Control Temp and do...

    Try to get on with Jones or Control Temp and do supermarket work. $125-130k / yr without much sacrifice as a J-man.
  10. Replies
    26
    Views
    2,944

    Testing for leaks with a vacuum is the same as...

    Testing for leaks with a vacuum is the same as pressure testing at 15 psi, not useful in any way.
  11. The ones I use to work on were Copeland 2-stage...

    The ones I use to work on were Copeland 2-stage compressors with hotgas bypass and liquid injection. The compressors never pumped down, just stopped feeding the evap coils.
  12. Replies
    14
    Views
    1,522

    Silly Safeway. I bet the EPA likes spill reports...

    Silly Safeway. I bet the EPA likes spill reports like this one.
  13. Replies
    54
    Views
    3,537

    No subcooling means no cooling. You can raise...

    No subcooling means no cooling. You can raise the feed to the evaporator to 2000 psi, but if it isn't liquid when it gets there....
  14. Replies
    17
    Views
    1,408

    I had an entire refrigerated warehouse for a...

    I had an entire refrigerated warehouse for a supermarket chain running backwards after an electrical company replaced the capacitor bank for the building. We just pulled the main breaker and waiting...
  15. Replies
    21
    Views
    1,496

    I'll bet if you tried shipping that to the Middle...

    I'll bet if you tried shipping that to the Middle East you'd end up in prison and on all the no-fly lists. It looks awesome.
  16. Replies
    32
    Views
    3,040

    I would refuse. They can put that sh*t in...

    I would refuse. They can put that sh*t in themselves, then answer the phone at night when the customer is calling.
  17. Replies
    43
    Views
    5,599

    That is standard issue in all the markets around...

    That is standard issue in all the markets around here. BTW, Bacharach makes nearly all leak detectors for everybody else. Very important if you are looking for technical help as they know their...
  18. Replies
    43
    Views
    5,599

    If you are talking about the portable Bacharach...

    If you are talking about the portable Bacharach unit, it has too many digits in it's price for my liking.
  19. Replies
    14
    Views
    1,422

    Sounds about right for Hussmann.

    Sounds about right for Hussmann.
  20. Replies
    14
    Views
    2,973

    My H10 still goes crazy around that stuff even...

    My H10 still goes crazy around that stuff even when it's 10 years old. Chlorine must be the first ingredient.
  21. Replies
    43
    Views
    5,599

    Carry your H10 probe at floor level at all times...

    Carry your H10 probe at floor level at all times while walking around and not checking cases. I've found many leaks accidentally this way due to the unexpected ways the air flows through a...
  22. Replies
    43
    Views
    5,599

    First lesson is the only thing that matters in...

    First lesson is the only thing that matters in supermarkets is money. Planet is not even a close second.
  23. When convenient. I use Celsius while talking...

    When convenient. I use Celsius while talking about the weather or with family, Fahrenheit talking about work, normally inches and feet but occasionally millimeters on construction projects. Most...
  24. Replies
    7
    Views
    4,900

    I hope the cycle lifespan is about 500x greater...

    I hope the cycle lifespan is about 500x greater than the current valves, because on my CO2 racks they are only lasting around 2 years. Almost as bad as Sporlan SER valves, but not quite. The screw...
  25. Replies
    7
    Views
    4,900

    Double post.

    Double post.
  26. Replies
    11
    Views
    1,934

    The info I can find online shows the new Audi A8...

    The info I can find online shows the new Audi A8 and the VW equivalent model running CO2.
  27. Replies
    11
    Views
    1,934

    My 2 year old Dodge Ram has R-1234yf in it and...

    My 2 year old Dodge Ram has R-1234yf in it and Mercedes was the one that had this refrigerant causing fires during crash tests, so they went straight to CO2. I would be very interested to see how...
  28. Replies
    107
    Views
    20,795

    They also make higher pressure N2 tanks if the...

    They also make higher pressure N2 tanks if the regular ones don't hold enough. 3000 psi, party on.
  29. Like the Carrier RTUs in the background, Im sure...

    Like the Carrier RTUs in the background, Im sure the equipment ducting will be extended once the crane shows up. The roofers do seem a little impatient to box everything in beforehand.
  30. Replies
    107
    Views
    20,795

    That doesn't sound as impactful, but is certainly...

    That doesn't sound as impactful, but is certainly more accurate.
  31. Replies
    107
    Views
    20,795

    CO2 is a refrigerant, not a purge gas. Flowing...

    CO2 is a refrigerant, not a purge gas. Flowing carbon through a pipe to prevent carbon buildup during brazing is a little counter productive.
  32. Replies
    107
    Views
    20,795

    Nitrogen doesn't react until well above brazing...

    Nitrogen doesn't react until well above brazing temperatures and is a fraction the cost of the other two gases, so it is ideal for working with copper and acetylene.
  33. Replies
    107
    Views
    20,795

    Nitrogen is not inert, but good enough for...

    Nitrogen is not inert, but good enough for brazing. Otherwise a truly inert gas is argon and helium.
  34. Replies
    5
    Views
    1,050

    Flooded evap?

    Flooded evap?
  35. Thread: What is this?

    by mspanky
    Replies
    13
    Views
    2,565

    The paint looks too pretty to be over-cooked,...

    The paint looks too pretty to be over-cooked, also I think I've only seen a cooked black indicator on an Alco, not a Sporlan. Looks like it was washed out with solvent or something and not charcoal...
  36. Thread: UltraSite32

    by mspanky
    Replies
    7
    Views
    1,498

    How long is the run between the RMCC and the PC? ...

    How long is the run between the RMCC and the PC? I would bring them together first for testing, then investigate the amplifier and cable itself if needed.
  37. Thread: rack superheat

    by mspanky
    Replies
    12
    Views
    1,721

    I don't think the ambient oil heater is working...

    I don't think the ambient oil heater is working properly.
  38. Replies
    15
    Views
    3,484

    Big Corporation, big bills. I'm sure a few...

    Big Corporation, big bills. I'm sure a few overpriced o-rings aren't going to hurt their bottom line.
  39. Thread: CO2

    by mspanky
    Replies
    30
    Views
    6,147

    Where is the heat going to come from if its cold...

    Where is the heat going to come from if its cold outside? A review of winter time heat-pump operation is needed.
  40. Thread: CO2

    by mspanky
    Replies
    30
    Views
    6,147

    My CO2 stores run around 190-195*F discharge...

    My CO2 stores run around 190-195*F discharge during the summer months, so not nearly as hot as my LT R22 stores.
  41. Replies
    12
    Views
    2,139

    Looks like dual DDR (defrost diff regs) to keep...

    Looks like dual DDR (defrost diff regs) to keep the cost down from one large valve.
  42. Replies
    16
    Views
    2,614

    Is the supply air velocity correct (honeycomb...

    Is the supply air velocity correct (honeycomb clean) and how uphill is the suction line running from the Tx bulb?
  43. Replies
    14
    Views
    2,156

    Typically, we have the 1st fan forced ON and the...

    Typically, we have the 1st fan forced ON and the condenser set point 10# higher than the holdback. As you found out, a lower condenser set point than holdback will never allow the condenser set...
  44. Replies
    18
    Views
    2,622

    Ok, now I see your problem. I need to stop...

    Ok, now I see your problem. I need to stop skimming posts.

    There should be a pressure drop of 10-15 psi across your holdback valve between the dropleg and the tank. Holdback will set your...
  45. Replies
    18
    Views
    2,622

    Why have a separator then if its going to be...

    Why have a separator then if its going to be bypassed?
  46. Replies
    18
    Views
    2,622

    Other than the tank filling up what other issues...

    Other than the tank filling up what other issues are there? It's very common for the liquid line sight glass to be 'rivering' and not filled to the top. It sound like the A9 solenoid should be...
  47. Replies
    18
    Views
    2,622

    The newer Hussmann vertical receivers I work on...

    The newer Hussmann vertical receivers I work on have a vent stub on the tank at the same height as the A9 inlet, or even higher. I will see if I can find some photos.
  48. Replies
    18
    Views
    2,622

    The top of the dropleg will be seeing the same...

    The top of the dropleg will be seeing the same pressure as the discharge line. The bottom of the dropleg has the same pressure plus the weight of liquid, as you had mentioned.
  49. Replies
    14
    Views
    2,362

    I think the guys thought you were looking for...

    I think the guys thought you were looking for specs for a new rink., not just maintenance. :oops:
  50. I would be very surprised if the system never...

    I would be very surprised if the system never came with a liquid receiver already installed, so yes that will be needed if the chiller uses a plate exchanger as an evaporator. I would also highly...