  1. i think those modules are junk, bout to get rid...

    i think those modules are junk, bout to get rid of my problem and install a icm phase monitor, wire the safteys into it and install a delay on break timer and be done with it
  2. are u in dc

    are u in dc
  3. thermostat question in relation to temp. offset, cycle rate per/hr, and short cycling

    ok so a thermostat had a supply diffuser blowing some what down on it, cust. did move the branch line over to return however, before it was moved a tech bumped the offset up to 5*f to help...
  4. carrier compressor alert diagnostic module ?

    carrier m# 38AUQA12A0A5A0A0A0
    so ive got one going out on short cycle alarm, was wondering if this could be related to the pressure switches cycling (there auto reset), getting ready to download...
  5. Replies
    13
    Views
    926

    This will never work , im sure theirs been...

    This will never work , im sure theirs been compressors changed out , install hot gas bybass for capacity control, head press. Control and run both compressors

    Sent from my SAMSUNG-SM-N900A using...
  6. Replies
    9
    Views
    473

    Id take some head gaskets with you to avoid a...

    Id take some head gaskets with you to avoid a trip to the supply house

    Sent from my SAMSUNG-SM-N900A using Tapatalk
  7. Exactly, im going back to the pneumatic stat and...

    Exactly, im going back to the pneumatic stat and kele makes a transducer that will work , gets a lil tricky cause I actually will need 2 transducers and they will need to calibrate to a specific...
  8. What about the cooling , and it might be too...

    What about the cooling , and it might be too difficult to pull a cable 4 floors
  9. Except the old one was pneumatic

    Except the old one was pneumatic
  10. Yeah , basically there was a stat on a floor for...

    Yeah , basically there was a stat on a floor for space temp control. It went to an old pneumatic step controller for the electric heat and to 2 pe switches. We replaced the heater and it needed a...
  11. outside ahu control with dx split coil ?

    Whats the best way to control mechanical cooling off of discharge air ?
  12. Replies
    43
    Views
    1,960

    50 k a yr is not alot of money nowadays, I shoot...

    50 k a yr is not alot of money nowadays, I shoot for double that
  13. Replies
    1
    Views
    241

    I had one tripping on low o2 too, engineer got...

    I had one tripping on low o2 too, engineer got the manufracturer to come out and they said it was the regulator , not sure if it fixed though , didnt make much sense to me , not my problem anymore...
  14. Replies
    55
    Views
    3,588

    http://ladderbuggy.com/features/

    http://ladderbuggy.com/features/
  15. Replies
    55
    Views
    3,588

    http://www.troweltrades.net/product_info.php?cPath...

    http://www.troweltrades.net/product_info.php?cPath=43_92&products_id=8009
  16. Replies
    55
    Views
    3,588

    i saw this thing you attach to your ext. ladder...

    i saw this thing you attach to your ext. ladder and winch it up
  17. 2 carrier 38AH 054 condensers losing mulitpe (06e) compressors ?

    so here is what we know: . single circuit and no branch off to solenoid valves for staging and only one txv on the evaporator coil. Also No oil trap at the ahu on suction line . Unit has 2) 25 ton...
  18. 40 ton txv on a 20 ton compressor ?

    Well not really , bad install . No LL solenoid valves and one txv on coil. Also No oil trap at the ahu on suction line . Unit has 2 20 ton carlyles . Also they ahu is 100% oa . Take a guess what...
  19. Replies
    1
    Views
    312

    Old Westinghouse

    I've got an old water cooled unit
    M# SH0551V
    Item# 761D034G11
    S# BX8526
    It's got a decent size semi recip. Sitting on top of the barrel that I'm trying to get manuals on , sorry didn't write...
  20. Replies
    10
    Views
    1,252

    cool pics, i've never seen the inside of one. if...

    cool pics, i've never seen the inside of one. if i suspect issues with a gearbox we bring in a company that specializes in tower work. is this a repair you guys do all the time ?
  21. Replies
    10
    Views
    817

    thanks ken

    thanks ken
  22. Replies
    10
    Views
    817

    i do it all really, but i'm willing to do...

    i do it all really, but i'm willing to do whatever the bossman tells me. here's part of my resume
    Qualifications

    Over 12 years in the trade, ranging in repair, installation, preventive...
  23. Replies
    10
    Views
    817

    Traffic??? Ur kidding right , I live and work in...

    Traffic??? Ur kidding right , I live and work in the DMV area . Can't get any worst than that lol
  24. Replies
    10
    Views
    817

    Is work steady, most of my experience is in...

    Is work steady, most of my experience is in commerical but I'm not biased lol
  25. Replies
    10
    Views
    817

    Thanks, my wife and I are seriously considering...