  1. Checked vigorously for leaks during nitro...

    Checked vigorously for leaks during nitro pressure check and evacuation. No leaks, no doubts.
  2. I applied for pro. The system was under charged....

    I applied for pro. The system was under charged. It's working great now. As I said, I think I moved the hose when I zeroed the scale so it was reading low. I slowly added r-22 while checking...
  3. I got it dialed in now. It was low on charge. I...

    I got it dialed in now. It was low on charge. I must have moved the hose on the cylinder when I was zeroing the scale.
  4. I added refer. Sh currently 30

    I added refer. Sh currently 30
  5. 66.2 register 80.1 intake grill 72 wet bulb ...

    66.2 register
    80.1 intake grill
    72 wet bulb

    83.3 ambient
    89.3 condenser outlet

    67/190 psi

    piston metering device
  6. That takes several weeks. I'll have it figured...

    That takes several weeks. I'll have it figured out by then.
  7. I'm going back out there now I suspect the charge...

    I'm going back out there now I suspect the charge is some how low but I don't see how because I weighed the charge exactly. The line set is 25 feet long roughly and I weighed out the recommended 72...
  8. 2 ton r-22 split system freezing at suction line

    Customer called and said in the middle of the night the unit stopped cooling and the suction line was covered with ice at the heat pump all the way to the compressor.

    Heat pump was just replaced...
  9. The main issue with them liming up is that when...

    The main issue with them liming up is that when they draw water through a coaxial fitting at the bottom of the tank they picku sediment in the bottom of the tank. This sediment then clogs the...
  10. Replies
    7
    Views
    2,004

    I was referring to this link:...

    I was referring to this link: http://www.renewability.com/power_pipe/index.html

    Perhaps it is you who should be doing the thinking. Legionella will grow in potable water that is allowed to stand...
  11. Replies
    5
    Views
    1,767

    :spam:

    :spam:
  12. Replies
    13
    Views
    1,930

    I also here that propress isn't good for...

    I also here that propress isn't good for application that are subject to constant vibrations. A voper compression system seems like the worst place to try to use propress.
  13. Replies
    13
    Views
    1,930

    I wouldn't think it could handle the pressures...

    I wouldn't think it could handle the pressures and temps in a 410A system.
  14. Replies
    29
    Views
    7,619

    Thanks for the info.

    Thanks for the info.
  15. Replies
    13
    Views
    1,930

    It would be faster but the material would be more...

    It would be faster but the material would be more than threading BI.
  16. Replies
    13
    Views
    1,930

    To be clear, you won't see cavitation in gas...

    To be clear, you won't see cavitation in gas lines, only water lines.

    I have seen cavitation in copper pipes due to not reaming cuts made by copper cutters. That will happen no matter what kind of...
  17. Replies
    29
    Views
    7,619

    Should I be looking at an open loop pump and dump...

    Should I be looking at an open loop pump and dump instead of closed loop?
    I can always replace the coil if it gets fouled. My only concern is energy efficiency. I can punch 2 holes in the ground...
  18. Replies
    13
    Views
    1,930

    At high water velocities if there are any...

    At high water velocities if there are any imperfections in the pipe wall cavitation will occur just behind the obstruction.
  19. Replies
    7
    Views
    821

    uhhh, what? water expands when heated not cooled.

    uhhh, what? water expands when heated not cooled.
  20. Replies
    13
    Views
    1,930

    What do you have against propress for gas? I...

    What do you have against propress for gas? I wouldn't trust it for potable water lines due to chemical attack and cavitation, but gas? Sure.
  21. Replies
    7
    Views
    821

    bad expansion tank?

    bad expansion tank?
  22. The best thing to do is buy a larger solar tank....

    The best thing to do is buy a larger solar tank. Look for tanks designed for open loop solar applications. They will have 5 ports on the top and 3 dip tubes. You usually get more mileage out of a...
  23. Replies
    29
    Views
    7,619

    sorry, i forgot about the price thing.

    sorry, i forgot about the price thing.
  24. Replies
    29
    Views
    7,619

    At 300' bore per ton, I would be looking at 1200'...

    At 300' bore per ton, I would be looking at 1200' feet total for a new 4 ton geo system. I'm not sure going geo would be an economically sound decision in my situation. I would estimate that the...
  25. If sized properly a single tank is just fine. You...

    If sized properly a single tank is just fine. You simply disconnect the lower element and leave the upper one attached. The upper element will only fire when you are about to run out of heat...