  1. rc5115 Do you still have the 33csdca090 damper...

    rc5115
    Do you still have the 33csdca090 damper motors and if so how much.

    Thanks
  2. Thread: Windows 8

    by fac 213
    Replies
    16
    Views
    1,364

    Ok Windows 8 seems to have issues, but has...

    Ok Windows 8 seems to have issues, but has anybody tried to load carrier service tool 2.2 onto windows 8 ? And thanks for the imput.
  3. Thread: Windows 8

    by fac 213
    Replies
    16
    Views
    1,364

    Windows 8

    Hi I am looking to get a new lap top. It comes with windows 8. Has anybody tried setting up carrier service tool on windows 8 yet. The version of service tool I have is 2.2.
    Thanks
  4. Replies
    0
    Views
    390

    Johnson Fan Controller

    I have two new P66AAB-39C single Condenser Fan Speed
    Controllers. Trane part number-436704290100. Operating range
    320 to 410 psig. Want to sell them togehter. Make me a reasonable offer.
  5. Thread: 33cst carrier

    by fac 213
    Replies
    1
    Views
    351

    33cst carrier

    On a 33cst monitor stat in config 1, there is a override time limit, and a timed override hours. Does anyone know what the difference is. I looked in the config book and can not find it. Thanks for...
  6. Replies
    0
    Views
    645

    York Rooftop info

    I have two York Rooftop units, that I am going to replace. Problem is the town inspector wants to know the weight of the unit, and the weight of the new unit, with the curb adabter. I have the cut...
  7. Replies
    5
    Views
    1,367

    Carrier varislide ecomonizers

    I have a few units that have the old slide econonizers. I called carrier to order the drive screw that connects to the motor and moves the damper up or down. Carrier can not find a part number. Does...
  8. Replies
    41
    Views
    5,825

    I think the kit Trane provides to correct the...

    I think the kit Trane provides to correct the failures is KIT15855 ( Trane kit number). I called for a price, quite expensive for some wires, and a contactor.
    Has anyone installed this kit ? Any...
  9. Replies
    41
    Views
    5,825

    Thanks for the info. I will check with my Trane...

    Thanks for the info. I will check with my Trane distributor tomorrow. I thought about installing a 24v isolation relay to break the 2 legs going to the cfm. The relay woud be powered from w1 going to...
  10. Replies
    41
    Views
    5,825

    I know the kit and wiring harness exists for the...

    I know the kit and wiring harness exists for the smaller Trane units with the negative gas pressure set up, but I am refering to a 12.5 ton voyager rooftop unit. If they did make a change , where can...
  11. Replies
    0
    Views
    499

    Old 20 ton York

    I have three york, DACW240 rooftop units. Does someone have the sequence of operations for the heat section. I have the wiring diagram. Thanks
  12. Thread: 25 Ton Voyager

    by fac 213
    Replies
    28
    Views
    1,952

    I believe trane uses a 2 pole contactor for the...

    I believe trane uses a 2 pole contactor for the Evap motor, even though it is
    3 phase. Did you checvk the Pri tap on the transformer to see if it matches the incomming voltage. Is the Transformer...
  13. Replies
    14
    Views
    2,014

    fxb80, I have two floppy's for the old service...

    fxb80,
    I have two floppy's for the old service tool 4 version 1.0. Is that what you are looking for? My e-mail is in my profile.
  14. Replies
    4
    Views
    1,155

    3 ton unit

    I am looking for one unit. How much are you selling it for. My e-mail is in my profile. Please let me know.

    Thanks
  15. Thread: Carrier

    by fac 213
    Replies
    6
    Views
    870

    Zone Controllers

    Acomo

    I have two Zone controllers, one bypass controller, two temp stats. Took them out of a job that had the old ACS program. They might be locked, I can not remember if I removed the lock with...
  16. Replies
    6
    Views
    1,499

    Had the same problem. The smoke detectors were...

    Had the same problem. The smoke detectors were system sensor type. The came factory installed in new Trane units. The units (2) serviced the kitchen area. They keep tripping and then the Fire Trucks...
  17. Replies
    16
    Views
    3,992

    Hope this helps I have not used it but it sounds...

    Hope this helps I have not used it but it sounds good


    Industrial/Commercial HVAC condensate pans are a common source of problems facing healthcare facilities. The two main issues being Indoor...
  18. Thread: Trane Varitrac

    by fac 213
    Replies
    3
    Views
    597

    Trane Varitrac

    I have a Trane Varitrac VAV system . It consists of two VAV boxes, and one bypass damper. Their is a control panel on the job and I can access Zone and system status and setup. The problem is the fan...
  19. Replies
    41
    Views
    5,825

    Sorry about the double post

    Sorry about the double post
  20. Replies
    41
    Views
    5,825

    Trane CBM failures

    I have had several CBM with the same problem, just running and no heat. Trane exchanged them under warranty. In fact they said hold on to the CBM
    they did no want it back. Today I had another CBM...
  21. Replies
    41
    Views
    5,825

    I have had several CBM with the same problem,...

    I have had several CBM with the same problem, just running and no heat. Trane exchanged them under warranty. In fact they said hold on to the CBM
    they did no want it back. Today I had another CBM...
  22. Replies
    7
    Views
    702

    Thanks r404a for the suggestions. It will take...

    Thanks r404a for the suggestions. It will take some doing, but I will find the leak. The machine is working like a champ right now. I still have the probe on the discharge line, and will stop every...
  23. Replies
    7
    Views
    702

    Went back to the nightmare job, the unit is FULL...

    Went back to the nightmare job, the unit is FULL of ice, and the discharge temp stayed below 200. There is a leak somewhere. I soaked the sol vales, access fittings, and all the rest with bubbles,...
  24. Replies
    7
    Views
    702

    Went back to the job today. The recorder showed a...

    Went back to the job today. The recorder showed a discharge line temp at 195 on the high end and 110 on the low end. Called the Tech guys at Manitowoc, and we determined the unit was low on gas. I...
  25. Replies
    7
    Views
    702

    BY1894N Remote Lockout on saftey limit 4

    Have a Manitowoc Ice Machine that Locks out on Saftey Limit 4 every once in a while. Pressures are 265-43 ( 265 taken at liquid line ) @ 80 outdoor temp on start up. Suction drops to 30 right before...
Results 1 to 25 of 45