Search:

Type: Posts; User: jrgreene1968

Page 1 of 2 1 2

Search: Search took 0.01 seconds.

  1. Replies
    17
    Views
    1,743

    this would be my reply:grin2:

    this would be my reply:grin2:
  2. Replies
    47
    Views
    5,163

    yeah, last year was not the normal year for sure....

    yeah, last year was not the normal year for sure. Its always hot here, more humid than hot, but last year was just plain scorching. I had a mild heat stroke last year, was a scary deal for sure
  3. Replies
    47
    Views
    5,163

    i lived in tacoma wa when i was a kid, and...

    i lived in tacoma wa when i was a kid, and visited portland alot, loved it up there. Now as far as texas heat, ..if i was a single man, id be in Portland, or Seattle, lol, every year i say im gonna...
  4. Replies
    20
    Views
    1,892

    anyway the board is incorrect and n/o and n/c are...

    anyway the board is incorrect and n/o and n/c are backwards on the relay

    be easy enough to tell with a meter though
  5. Replies
    26
    Views
    1,983

    oh yeah, got the service call, and diagnostic...

    oh yeah, got the service call, and diagnostic fee, buddy said this has happened to him one other time at the same house, said the ole man will be just happy go lucky then just bam, like he is a...
  6. ive done it, but it was discussed upfront, only...

    ive done it, but it was discussed upfront, only my labor came with a warranty. But it was also for a good customer
  7. Replies
    26
    Views
    1,983

    well there was a couple times i caught my self...

    well there was a couple times i caught my self laughing at some of the requests, and 1 guy im not sure what happened..we got there, coil was froze, found the blower relay bad, so i start pulling it...
  8. Replies
    26
    Views
    1,983

    customers nickel and diming

    i work on gas compressors and gas refrigeration units, cost is no exception, whatever it takes, as fast as it takes. Ive been doing this for a long time, and have been thinking of maybe moving over...
  9. Replies
    28
    Views
    3,043

    my truck has a service bed, and i work out of...

    my truck has a service bed, and i work out of town alot. In 25 yrs, ive been ripped off, 3 times. The last time in Corpus Christi Tx, they cleaned the truck out, lol... they must have spent most the...
  10. Replies
    3
    Views
    493

    we used some dynamat type stuff one time, its a...

    we used some dynamat type stuff one time, its a butyl based deadener if i remember right. It does work, but i remember its heavy. I remember reading somewhere that homedepot sells something similar...
  11. Replies
    27
    Views
    2,510

    i went ahead and ordered the cooper, since my...

    i went ahead and ordered the cooper, since my fluke crapped out on me, but i dont think it was any fault of the fluke..that thing has been dropped, stepped on, sit on, probably thown lol, but im...
  12. Replies
    53
    Views
    3,453

    exactly...i had been getting odd readings lately...

    exactly...i had been getting odd readings lately with my fluke, and couple days ago was setting a new gas chiller, another guy helping me had a brand new cooper sh66 , so we compared his to my fluke...
  13. Replies
    53
    Views
    3,453

    i chased my tail other day, found out my fluke...

    i chased my tail other day, found out my fluke 80pk clamp was my problem
  14. Replies
    27
    Views
    2,510

    Thanks, I'm going to order one, i like the...

    Thanks, I'm going to order one, i like the cordless idea, I've had cooper stuff in the past, without any problems
  15. Replies
    27
    Views
    2,510

    Cooper cordless pipe clamp thermeter

    Anybody using the cooper cordless pipe clamp digital thermometer? Wandering how accurate it is? I've been using a fluke clamp but it's acting up
  16. Replies
    7
    Views
    924

    i bought one last year..dont much care for it. I...

    i bought one last year..dont much care for it. I used it once and put it on the shelf. Takes to long to heat, hard to get flame to stay lit, hard to hold bottles
  17. Replies
    10
    Views
    2,201

    thanks for the replies had a guy out today,...

    thanks for the replies

    had a guy out today, same one that was here last few times..so he is pretty familiar with the problem. He checked pressures again, along with sh and sc. Also checked...
  18. Replies
    10
    Views
    2,201

    the house sits on pier and beam, and the lineset...

    the house sits on pier and beam, and the lineset runs under the house and then through the floor into a closet. The air handler is installed in a closet off the floor. No return duct, just a big...
  19. Replies
    10
    Views
    2,201

    thanks for the reply. Coils have been cleaned,...

    thanks for the reply. Coils have been cleaned, filter changed. Pressures checked. With normal superheat, it only has 2 degrees of subcooling. Humidity in house is right at 51%.
  20. Replies
    10
    Views
    2,201

    low subcooling

    if a piston orifice is overfeeding, stuck, etc, would the system still work..just not as designed? Our system has always struggled to cool house if outdoor temp gets above 92 or so. Has been checked...
  21. Replies
    4
    Views
    529

    blower speed

    my temp split on supply/return registers is 15 degrees with blower set to high speed. If i set the blower to medium, i get 18-19 degree split. which is better? Wish it was 20 degree on high speed
  22. Replies
    78
    Views
    4,422

    please post what the tech comes up with..i have...

    please post what the tech comes up with..i have the exact same problem:D i have had mine checked by 2 different companies, and keep getting told its doing all it can, its just hot out.
  23. Replies
    6
    Views
    724

    dont think they checked it at the coil..there is...

    dont think they checked it at the coil..there is no access to the coil, how would i check it? The sheetmetal on top of air handler dont have any acess covers. The handler dont have any return duct....
  24. Replies
    6
    Views
    724

    the old one didnt keep up either, reason...

    the old one didnt keep up either, reason installer went up to 4 ton. Have had unit checked out by 2 different companies, they both said its doing what it can, but still wont keep up on a hot day. We...
  25. Replies
    6
    Views
    724

    faster blower motor

    if the supply registers read on the low side on a temp split, and everything has been checked, would installing a little higher rpm blower motor solve the problem to get more temp split?

    My ac...
Results 1 to 25 of 36
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event