  1. Natural gas 97% efficient

    Natural gas 97% efficient
  2. lock out temp recommendations for heat pump

    I have a Goodman dszc160241ae which has an hspf of 9.5. My break even point is a cop of 2.454. Was wondering what temp I should set the cut out temp of the heat pump at. I currently have set at -6.5c...
  3. Replies
    13
    Views
    616

    Will require looking in to. Only option may be to...

    Will require looking in to. Only option may be to set the fan in continuous run mode
  4. Replies
    13
    Views
    616

    Cut old terminal block so it will not include r&c...

    Cut old terminal block so it will not include r&c should then be able to insert both. Of course this is only if can't find better idea
  5. Replies
    13
    Views
    616

    Did some research. When furnace fan is running...

    Did some research. When furnace fan is running using communication g is 0v compared to c. If r and g are shorted like hrv would normally do to demand air fan will star when in auto by communication....
  6. Replies
    13
    Views
    616

    Ok. So my only option to keep this thermostat is...

    Ok. So my only option to keep this thermostat is to throw a fan proving switch in to act as g contact.
  7. Replies
    13
    Views
    616

    Autocorrect error: threatened=trueSteam

    Autocorrect error: threatened=trueSteam
  8. Replies
    13
    Views
    616

    Sorry just checked schematic and board. G and R...

    Sorry just checked schematic and board. G and R are required and no extra contacts. The humidifier(Honeywell threatens w/h8908aspst) does have an auxiliary fan contact but I think that probably runs...
  9. Replies
    13
    Views
    616

    thanks. Just so I have options to give GC when I...

    thanks. Just so I have options to give GC when I explain why I can't wire it up. would any Goodman HRV work with the system or only specific ones? I assume another brands would not work.
  10. Replies
    13
    Views
    616

    HRV with goodman GMVC95 with Fantec HRV

    I am an electrician and the guy installing the furnace provided me with a CTK03 thermostat which is a 4 wire communicating thermostat. I have no problems hooking this up to the furnace and the heat...
  11. Replies
    14
    Views
    1,253

    So any extra volume in duct pre dampers will not...

    So any extra volume in duct pre dampers will not deteriate the efficency of the system? I am definetly thinking the career system is the better system. It is just to bad that trane's main thermostat...
  12. Replies
    14
    Views
    1,253

    I will install the pexs in the basement and...

    I will install the pexs in the basement and garage slabs for future hydronic heating. For now though I want to focus on ducted heat as that can cool also(we have very hot summers also no middle temps...
  13. Replies
    14
    Views
    1,253

    Sorry. Well without prices(even hypothetical...

    Sorry. Well without prices(even hypothetical ones) there is no point discussing the zone arrangements other than to say I am willing to reduce zone count to keep project economical.

    Thank you for...
  14. Replies
    14
    Views
    1,253

    Thanks that is a good thing to know. George the...

    Thanks that is a good thing to know. George the purpose is to save money on heating bills not upfront cost. Combining the 3 rooms would save me $ but give me less control on bedroom temps. Admittedly...
  15. Replies
    14
    Views
    1,253

    The trane dampers are only $ at the wholesaler...

    The trane dampers are only $ at the wholesaler and thermistors are only $ so ducts and Labour are the expensive part. Most contractors I have talked to said I would have to do all the controls once...
  16. Replies
    14
    Views
    1,253

    5 on main floor: 1 per bedroom plus main area 5...

    5 on main floor: 1 per bedroom plus main area
    5 in basement: 2 bedrooms, media room, play room, storage

    Reason for splitting is to be able to set areas as unoccupied. Bedroom walls are all...
  17. Replies
    14
    Views
    1,253

    Zoned System Ducting Advice

    I am looking to build a house next spring just north of Winnipeg, Manitoba, Canada. I wish to put in a zoning system to allow for more efficient use of heating and cooling energy and to keep the...