  1. You should be able to go into menu and go to test...

    You should be able to go into menu and go to test outputs and energize hmv which is the solenoid to check contacts on board. It's been a while since I have worked on any lieberts but check the limit...
  2. Replies
    0
    Views
    392

    Honeywell webstat

    I am doing a webstat job, I have already installed and configured the t-stats with lonspec. I am just waiting on controllers to finish the job. I was just curious if any one has installed any, was...
  3. Replies
    4
    Views
    475

    A friend of mine had a registered copy on his...

    A friend of mine had a registered copy on his labtop and I downloaded it on my labtop and did not register it. It was good for 30 days.
  4. Replies
    4
    Views
    633

    I got it to work, I just used my pcmia card and...

    I got it to work, I just used my pcmia card and hooked to communication screws and configured the t-stat. Thanks
  5. Replies
    4
    Views
    633

    honeywell t7350

    I have t7350 webstats I am installing. I am trying to configure them while in stand alone. I have lon spec and hooked up to the ethernet jack on bottom of stat and to ethernet jack on labtop. I have...
  6. Replies
    9
    Views
    1,539

    Thats what I am looking for, I will look further...

    Thats what I am looking for, I will look further in to each dialer. Thanks alot.
  7. Replies
    9
    Views
    1,539

    server room auto dialer

    I am looking for a stand alone controller that I can set a high temp alarm to dial out or send a text message. I was looking at honeywells web stat, but it sends out only emails. Any suggestions.
  8. Replies
    7
    Views
    507

    Thanks , I would say he knows the furnace then. I...

    Thanks , I would say he knows the furnace then. I will pull the orfice out and check the valve for blockage.
  9. Replies
    7
    Views
    507

    Yes, I am a commercial service tech, not seen...

    Yes, I am a commercial service tech, not seen many colman furnaces.
  10. Replies
    7
    Views
    507

    coleman furnace question

    I got a 2005 coleman dgaa077bdta mobile home furnace. It was 55 degrees in space and discharge air was 64 while it was heating. The problem is of course a low discharge air temp. My incoming gas was...
  11. Replies
    5
    Views
    1,337

    I Agree York Is A PAIN In The Butt To Deal With....

    I Agree York Is A PAIN In The Butt To Deal With. My Rep Will Not Even Return My Call.
  12. Replies
    5
    Views
    1,337

    york literature

    I was looking for a IOM on a york YCUJ54OE8-46pa, I did not have any luck on johnsons website. Any help were I could find it. Thanks
  13. Replies
    14
    Views
    1,430

    Thanks For All The Help, I Got A Hold Of The...

    Thanks For All The Help, I Got A Hold Of The Service Bulletins. They Are Pretty Detailed. It Is The Same As What You All Said. I Will Bid To Do Both.
  14. Replies
    14
    Views
    1,430

    Thanks for the help. Do you just change the...

    Thanks for the help. Do you just change the piston or the piston and slide valve. I have not been in the trane screws, is it a bad job.
  15. Replies
    14
    Views
    1,430

    It does not unload at all, It starts at 85% and...

    It does not unload at all, It starts at 85% and goes to 120% fla and then locks out on low oil. It runs about a minute.
  16. Replies
    14
    Views
    1,430

    I didnt think the lip seal could be replaced in...

    I didnt think the lip seal could be replaced in the field, Do you port the unload solenoid external of the compressor.
  17. Replies
    14
    Views
    1,430

    rtaa piston problem

    I have a trane rtaa155 that is tripping on low oil pressure within in a minute of start up. It is starting at 85% load, The unload coil is getting power at startup. I ran the piston cavity schrader...
  18. Thread: t7300f

    by pipefitter2005
    Replies
    3
    Views
    473

    Dial it up like using hiperterminal, is it doss...

    Dial it up like using hiperterminal, is it doss based.
  19. Thread: t7300f

    by pipefitter2005
    Replies
    3
    Views
    473

    t7300f

    I worked on a honeywell t7300 t-stat with a communicating subase on a single rooftop. It had a router and outside phone line hooked up. I have read that it is lon works. But the customer was not...
  20. Replies
    22
    Views
    1,431

    Rover Questions

    I Have Been Around Alot Of Trane Controls, I Have Never Used The Rover Software. I Have The Software Now And The Accesories. What All Can You Do With The Rover Program. I Believe It Has Com 4and 5...
  21. Replies
    21
    Views
    3,363

    Turn the electostatic filter off and see if the...

    Turn the electostatic filter off and see if the smell goes away. Might be ozone like tecman said.
  22. I think the c16 had metal drain pans, it could...

    I think the c16 had metal drain pans, it could have rusted a hole in the pan.
  23. Ok, but the small hot gas line off the...

    Ok, but the small hot gas line off the compressor would enter a muffler not a drier. Drier would be in liquid line out of condensor.
  24. Replies
    5
    Views
    599

    Ok, Then there is nothing you could of did to...

    Ok, Then there is nothing you could of did to cause that to happen.
  25. Like psycho said the small discharge line comes...

    Like psycho said the small discharge line comes out the side at the very top on scroll. Take the blanket off and look. Recep comes out the bottom.
Results 1 to 25 of 58