Search:

Type: Posts; User: chewbacca

Page 1 of 3 1 2 3

Search: Search took 0.01 seconds; generated 13 minute(s) ago.

  1. Replies
    32
    Views
    1,621

    I stand corrected. Thanks for the info, guys

    I stand corrected. Thanks for the info, guys
  2. Replies
    32
    Views
    1,621

    When air is heated, it expands and therefore...

    When air is heated, it expands and therefore holds fewer grains of moisture per cubic foot. If you take rh readings before and after your coil, you should see higher readings after the coil, even...
  3. Replies
    8
    Views
    436

    I get a lot of noise complaints on carrier 13...

    I get a lot of noise complaints on carrier 13 seer heat pumps. Compressor isolation bolts work great if it's a vibration issue
  4. I'm glad I read this thread. I also have a habit...

    I'm glad I read this thread. I also have a habit of turning off gas valve to cool hx before disconnecting power
  5. Thread: Here's a few

    by chewbacca
    Replies
    13
    Views
    2,475

    Buzz bait. I love top water fishing.

    Buzz bait. I love top water fishing.
  6. Thread: Here's a few

    by chewbacca
    Replies
    13
    Views
    2,475

    That's exactly what happened. An inexperienced...

    That's exactly what happened. An inexperienced coworker was there a day or two before me an added about four pounds trying to raise suction pressure.
  7. Thread: Here's a few

    by chewbacca
    Replies
    13
    Views
    2,475

    First 2 pics are shame. Just threw the bass in...

    First 2 pics are shame. Just threw the bass in there
  8. Thread: Here's a few

    by chewbacca
    Replies
    13
    Views
    2,475

    Yeah I kept him and a few of his friends. I...

    Yeah I kept him and a few of his friends. I normally release the bigger ones, but the owner of the lake plans on draining it soon, and wants it fished out
  9. Thread: Here's a few

    by chewbacca
    Replies
    13
    Views
    2,475

    Thanks

    Thanks
  10. Thread: Here's a few

    by chewbacca
    Replies
    13
    Views
    2,475

    Here's a few

    428871428881minor restriction 15 psi low 480 psi head428891 house fire 428901nice bass
  11. Wow! What did the coil look like?

    Wow! What did the coil look like?
  12. Replies
    63
    Views
    4,724

    Needs to cut at least up to 1 1/8". I've had good...

    Needs to cut at least up to 1 1/8". I've had good luck with ridgid and Lenox. As for a meter I would start with a fluke 902 or fieldpiece hs36
  13. Replies
    63
    Views
    4,724

    You will need a bigger tubing cutter

    You will need a bigger tubing cutter
  14. Dtek select

    Dtek select
  15. I don't know why nobody likes the inficon. Mine...

    I don't know why nobody likes the inficon. Mine has served me very well. Not very good for 410, but neither is my h10. We just charge a little more for 410 leak searches to cover pumping system down...
  16. Replies
    11
    Views
    831

    Even if I have no reason to suspect low charge,...

    Even if I have no reason to suspect low charge, the customer always asks if I checked the antifreeze/freezone/ juice, so I check on virtually every call.
  17. Replies
    12
    Views
    955

    Was it a dry charged condenser? Did you let out...

    Was it a dry charged condenser? Did you let out the nitrogen?
  18. Replies
    65
    Views
    5,295

    I rarely have to use it, but when I do, my motor...

    I rarely have to use it, but when I do, my motor puller is worth it's weight in gold
  19. I ran a pm a few weeks ago. Both temp clamps for...

    I ran a pm a few weeks ago. Both temp clamps for my testo gauges quit working that day. I checked airflow, delta t, amp draws, etc. suction line was sweating. I called it good. Coworker was called...
  20. Replies
    19
    Views
    2,363

    Our only issues were on the newer sta furnaces....

    Our only issues were on the newer sta furnaces. Hundreds installed, maybe 2 or 3 callbacks. All with return on left side. I was just curious.
  21. Replies
    19
    Views
    2,363

    Jimmy, do you ever have air flow issues with the...

    Jimmy, do you ever have air flow issues with the return drop on the left side like that? We use an 8 inch box like you do,and have had a few with the right side limit was overheating. Not enough air...
  22. Replies
    8
    Views
    600

    I bought the smallest one I could find. $20 at...

    I bought the smallest one I could find. $20 at Home Depot. Not very powerful, but good enough for tune ups. I forget the brand name
  23. Replies
    21
    Views
    3,563

    Is that soft copper? Looks good. Boss has our...

    Is that soft copper? Looks good. Boss has our guys use pex for desuperheater. Looks like crap. I'm anxious to see your linesets. I've never been happy with mine on those split systems.

    Sent from...
  24. Usually though, if new construction issue was due...

    Usually though, if new construction issue was due to installation, diagnostic fee is refunded.
  25. We have 24 hour service. Replacement and...

    We have 24 hour service. Replacement and maintenance customers get warranty service after hours. New construction warranty issues pay diagnostic fee after hours, and repair is warranty.
Results 1 to 25 of 75
Page 1 of 3 1 2 3
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event