  1. Thread: head pressure

    by mckim
    Replies
    44
    Views
    2,668

    What about when its -20 degree !?

    What about when its -20 degree !?
  2. Thread: Copeland

    by mckim
    Replies
    22
    Views
    1,604

    That all sounds great Stonewall What about the...

    That all sounds great Stonewall What about the original question " why do they not list it on the compressoe"?
  3. Thread: Copeland

    by mckim
    Replies
    22
    Views
    1,604

    Maybe some these Gurus can weigh in on this!! I...

    Maybe some these Gurus can weigh in on this!! I too have been getting pissed off when i look for the fla and they do not have it on the compressor. Why in the hell do they think listing the lra is...
  4. Thread: Ice Cream WIF

    by mckim
    Replies
    71
    Views
    3,549

    Get the dam door fixed and quit changing parts!!...

    Get the dam door fixed and quit changing parts!! Read all the post-- Your condenser is ok and your head pressure is ok! If you keep letting in air your going to ice-up and not reach setpoint!! 101!!!!
  5. Replies
    10
    Views
    2,955

    E2

    Phase Loss-- If you wired it straight across line would'nt you be acheiving the same as wiring it in with 4 or nc output?

    Mckim
  6. Replies
    10
    Views
    2,955

    E2

    If you do not wire the E2 in series with 4 or nc output and the LLS how else would you wire it?

    Mckim
  7. Thread: tyler rack

    by mckim
    Replies
    9
    Views
    619

    tyler rack

    Is this A82bl valve a liquid differental or discharge differental? If liquid differental, should it go between the reciever outlet and the liquid header?

    Thanks,

    Mckim
  8. Thread: tyler rack

    by mckim
    Replies
    9
    Views
    619

    tyler rack

    I work for a company that is putting in a supermarket for a customer that has bought used hill/phoenix cases and a tyler (envireguard) low temp. rack 1991 model# P9OL-31 SERIAL # w628933 And a...
  9. Replies
    31
    Views
    5,892

    tyler rack

    I work for a company that is putting in a supermarket for a customer that has bought used hill/phoenix cases and a tyler (envireguard) low temp. rack 1991 model# P9OL-31 SERIAL # w628933 And a...
  10. Thread: RACK

    by mckim
    Replies
    7
    Views
    800

    rack

    Thanks for all the responses! I eliminated risers and bent elbows. Replaced old SORIT 15 with a new SORIT 20 and boom she took off!!! Now have equal pressures at evap. coils and same as at sorit....
  11. Thread: RACK

    by mckim
    Replies
    7
    Views
    800

    RACK

    Install department just relocated 3- 3 door ice cream cases (zero zone). Hill/phoenix r22 low temp. rack, compound carlyes. Got call cases will not drop below -2 setpoint is -10 to -17. Checked...
  12. Thread: Rack

    by mckim
    Replies
    0
    Views
    409

    Rack

    I am doing a start-up on a Kysor/Warren low temp. rack model #TD400-030-PL-3-NH2E-B Hot Gas defrost R507.

    I have my vacuum pump hooked up to a spare circuit suction 1-5/8 and liquid 7/8 inch. I am...
  13. Thread: suction float

    by mckim
    Replies
    18
    Views
    1,180

    Suction Float

    how does floating suction differ from the parimeters set on the controler--? say 30 and 35 is this not the same as float? I understand the objective-- saving money!! -- the higher the suction=lower...
  14. Thread: suction float

    by mckim
    Replies
    18
    Views
    1,180

    A Rack system!

    A Rack system!
  15. Thread: suction float

    by mckim
    Replies
    18
    Views
    1,180

    float suction

    I am refering to a control strategy particually Novar. As it was explained to me all SORItS run 100% of the time! The two coldest circuits are used for temp control and the superheat will control...
  16. Thread: suction float

    by mckim
    Replies
    18
    Views
    1,180

    suction float

    Can anybody explain how to set-up Suction float?

    regards,

    mckim
  17. Thread: Novar

    by mckim
    Replies
    0
    Views
    621

    Novar

    Has anybody found how to adjust the screen on the RC2XE?! Tired of following that dam x around circles!!

    Regards,

    mckim
  18. Replies
    15
    Views
    1,126

    start-up

    Should I frontseat the suction service valves on intial start-up and at what point should the oil regulators be adjusted? Will it hurt the solenoid coils having them energized durrung vacuum with no...
  19. Replies
    15
    Views
    1,126

    start-up

    Are the liquid dryer cores in on first vac and do you eventully take out the suction cores If rack floods backseverly should x/valves be ajusted.

    Regards,

    mckim
  20. Replies
    15
    Views
    1,126

    start-up

    Sounds great! What is the next step?

    Regards,

    mckim
  21. Replies
    15
    Views
    1,126

    new rack start-up

    Anybody have a good A TO Z start-up procedure to follow when starting up new racks Hill/Phoenix in this case ? Two LT and Two MT"s running a varyity of different manufactures cases. Air cooled...
  22. Replies
    17
    Views
    1,339

    controller

    Do you have com-trol's phone# and website?
  23. Replies
    12
    Views
    1,241

    I have not had any experience with this system....

    I have not had any experience with this system. It seems like so many other new technologies being introduced into the field today. You not only here it here on this sight but at that supplyu houses...
  24. Replies
    18
    Views
    1,467

    headers

    Thanks for that link stevenj! It is beginning to become clearer to me that market design and application varies on what part of the country you are at. Hussmann years ago made what was called a split...
  25. Thread: end of the run

    by mckim
    Replies
    10
    Views
    688

    end of the line

    Repair the leak, clean the strainers, and install new filter/dryers! Set superheat at 10 degrees on each x/pansion valve.

    Regards,

    mckim