    Was it ever shipped UPS ? Ross Kious

    Was it ever shipped UPS ?


    Ross Kious
  2. Replies
    14
    Views
    1,186

    This on gets my vote . Look for a oversized...

    This on gets my vote . Look for a oversized condenser , wrong evaporator ect.


    Ross Kious
  3. Replies
    25
    Views
    1,423

    don't worry be happy...

    If you have a -10 freezer a -20 sst would be normal . IF you have 30
    degree's of superheat at the compressor that would give you 10 degree
    suction line . If you have a 10 to 20 degree suction...
  4. Replies
    1
    Views
    552

    Scotsman icemaker pump

    Hey,

    I have a scotsman 12-2582-21 ice machine pump that
    servicer called me about. All I have in stock is the BRPAP1 ,
    which does not have the side mounts on the motor . They are
    asking...
  5. Thread: hey...

    by rkious
    Replies
    6
    Views
    524

    yes....

    7 in blade will not fit it (to large) . He would use a 6 if I could find one .....
    I had never seen a 6 1/2 inch blade until that one got thrown on my desk.

    Thanks,

    Ross Kious
  6. Thread: hey...

    by rkious
    Replies
    6
    Views
    524

    hey...

    I have someone with a 6 1/2 blade, ccw rotation, 5/16 shaft , 5 blades , and
    about 28 degree or greater pitch (metal) . Anybody have any ideal of a part
    number for something that would fit ? No...
  7. Replies
    17
    Views
    1,953

    hmmm.

    "I've vacuumed down the system twice to 25 inches" ?????. 24 hours--
    -- your vacuum pump must really suck!!! or you have a leak .


    Ross Kious
  8. Thread: Part number.

    by rkious
    Replies
    6
    Views
    730

    Yep.

    I have bought them local before ...... just trying to find a part number that
    might be in my system . 1802000001 and 1803000001 is one of my suppliers numbers (just had to hit the right book).
    ...
  9. Thread: Part number.

    by rkious
    Replies
    6
    Views
    730

    Sorry , I understand the refrigeration end...

    Sorry ,


    I understand the refrigeration end of things .... I can build a txv valve , size
    a unit look up compressor , but since I took over the managers job at a ACR
    supply house the...
  10. Thread: Part number.

    by rkious
    Replies
    6
    Views
    730

    Part number.

    Hey,


    I have someone looking for a 4 inch globe for a walk-in-cooler (and the next smaller size. Wouldanybody off the top of their head know the part number for these ?? I went through about a...
  11. Thread: Wtf!?!

    by rkious
    Replies
    19
    Views
    1,333

    Now you know why they wanted you to send the...

    Now you know why they wanted you to send the mercury thermostats back in to be recycled :D . Kinda joking , but we should watch what we pour into our rivers and oceans . This is coming from a guy...
  12. Replies
    7
    Views
    1,522

    If you have 24 volts to the valve .... and proper...

    If you have 24 volts to the valve .... and proper pressure at the inlet , plus with the valve knob is turned on , you should have gas coming out . ( use a manometer at the outlet test port ) . In...
  13. Just soak some hotdogs in antifreeze .... works...

    Just soak some hotdogs in antifreeze .... works everytime :D .
  14. Replies
    33
    Views
    1,760

    Homeschooling is not for everyone , but its a...

    Homeschooling is not for everyone , but its a option that you can look at . My wife homeschools our kids and they score very well on the state required test .

    Ross Kious
  15. Replies
    0
    Views
    476

    Got a Extra ACCA manual D in by error . My Dad...

    Got a Extra ACCA manual D in by error . My Dad ordered a book for my birthday , and got the wrong one in mistake . He should have gotten the new Diag and repairing ductwork by ACCA, but got manual d...
  16. Thread: test

    by rkious
    Replies
    0
    Views
    332

    :rolleyes: :) :( :D ;( ;)

    :rolleyes: :) :( :D ;( ;)
  17. Replies
    23
    Views
    1,697

    Does not matter if nothing is in the closet .......

    Does not matter if nothing is in the closet .... The return air is were the "corroision" is more than likly coming from . Return air can suck in bleach fumes , cat littler box fumes , sewer fumes or...
  18. Thread: Test Wensday

    by rkious
    Replies
    10
    Views
    633

    passed

    Passed this time (Class A Arkansas unlimited scope ) . Stayed calm and it was a whole lot easier . Just ignored the alien questions .



    Ross Kious
  19. Thread: Test Wensday

    by rkious
    Replies
    10
    Views
    633

    Yeah.

    Yeah I saw that after I posted . :D tried to change it but I guess you can not change the subject of a post . The Test is ICC .


    Thanks,

    Ross Kious
  20. Thread: Test Wensday

    by rkious
    Replies
    10
    Views
    633

    test

    Got the Arkansas Class A HVAC test in the morning . Failed last time by a couple of points . I did not study very good last time and this time I can almost quote the mech. and Gas code . There are...
  21. Replies
    55
    Views
    2,653

    Energy

    A company that makes a profit off of energy . Price is only going to go up .


    Ross Kious
  22. Replies
    8
    Views
    727

    Maybe...

    Maybe his boss came across the wall of shame ? :D
  23. Replies
    9
    Views
    3,256

    DIY

    DIY getting his goods to do his own install ??
  24. Replies
    5
    Views
    1,812

    nice

    Nice artwork....



    Ross Kious
  25. Thread: hurt on the job

    by rkious
    Replies
    6
    Views
    1,102

    torch to defrost the coils ?

    Was he using a torch to defrost the coils and busted a spot in the line and oil sprayed out and caught him on fire ? The story says the freon caught on fire ( yeah right!!) . This is the only thing...
  26. Replies
    17
    Views
    1,595

    hhmmm

    He can not pull the wool over our eyes !! ... Even steel wool
    , which he probley needs :D
  27. Replies
    108
    Views
    4,871

    I Did not know that could happen ...( I knew it...

    I Did not know that could happen ...( I knew it could kill a person ) . I have had phosgene gas to burn my lungs , eyes and nose. Since It became law to recover refrigerants ,it has only happen Once...
  28. Replies
    27
    Views
    4,011

    Re: Re: liners

    Does it have anything to do with a Induced Draft Furnace being common vented with a nat. draft waterheater ? Thats the only thing that I see that I do not like .

    Ross Kious
  29. Thread: evap ice up

    by rkious
    Replies
    6
    Views
    866

    either way

    Could be a restriction or a bad txv ... either way call a pro.
    a lot of the time I have cust. to work on a system and end up
    spending more trying to fix it than what I charged them to fix it.
  30. Replies
    19
    Views
    1,772

    What does the subcooling do when the pressure,s...

    What does the subcooling do when the pressure,s go wild ? Does your static pressure stay the same when the readings go up and down ?


    Ross Kious
  31. Replies
    19
    Views
    1,765

    INSTALLERS

    Maby the orginal installer never got called back to do the startup ?
  32. Replies
    200
    Views
    13,442

    Re: Re: nitrogen

    Using a slow nitrogen purge while brazing is not a "must". I routinely visit homes and perform maintenance on AC's that are 15, 20, and 25 years old that are running great where NO NITROGEN PURGE...
  33. Replies
    200
    Views
    13,442

    nitrogen

    I can not believe a tread has grown to this size over a issue that everyone know the answer to. Nitrogen used during brazing is a must .... That being said "Airflow problems " kills more compressor...
  34. Replies
    52
    Views
    3,600

    Yes but the engineers tested the match system ...

    Yes but the engineers tested the match system and knows how it will respond to the load changes..... but as the field rep. for rheem said yesterday(in a tech school) , we not going to spend the $$...
  35. Replies
    4
    Views
    2,063

    Subcooling

    Most of the time when you have a real high subcooling on the liquid line it means that you either have too much refrigerant or a restriction some were . Having to much refrigerant makes your...
  36. Replies
    5
    Views
    670

    ASH PAN

    Just get one with a good ash pan and its not that bad. We sell Applalachian Wood stoves and the feed back that we get on them is that most people just have to take out one pan (not full) of real fine...
  37. Replies
    17
    Views
    2,120

    Airleaks

    Sure sounds like air leaks to me...
  38. Thread: test help

    by rkious
    Replies
    7
    Views
    1,304

    test

    ICC
  39. Thread: test help

    by rkious
    Replies
    7
    Views
    1,304

    class A test

    what kind of questions did they have on plans reading ? In general was the electrical about breakers and wire sizing ? I am about to go and ungrade to a class A lic. (BTW) how did you do?


    ...
  40. Replies
    15
    Views
    2,256

    pile of dung

    one time I went to work on a refrigerator (not cooling)
    and they showed me to the back room . The whole house smelled like a outhouse . I found out why . Next to the refrigerator was a pile of...
  41. Thread: Delta T

    by rkious
    Replies
    9
    Views
    2,078

    temp rise

    And if its a high efficiency furnace stay away from the lower range if you can . About mid-range or a little higher to avoid moisture issues.
  42. Replies
    194
    Views
    20,361

    You might be a hack if

    You can put a part on faster than you can pull out your meter.
  43. Replies
    6
    Views
    1,513

    PTC

    Yes , I know that PTC Relays creates their own heat . It is based on this fact that they work ( rise in temp , increased resistance ) . The reason I think that its the heat from the compressor that...
  44. Replies
    6
    Views
    1,513

    PTC Relays

    The PTC Relays sure are a Good Money maker!. Heat gets to that type of Relay after a while . The old Current Relays lasted forever ( At least they seem to ). I know the overload needs to stay on...
  45. Replies
    58
    Views
    10,693

    Bacharach Fyrite Tech 60 Combustion Analyzer

    The Bacharach Fyrite Tech 60 Combustion Analyzer looks like a
    good buy ( a little over $400.00 ) and it seems to include everything I need . Was wondering if any of you had and what you thought...
  46. Replies
    25
    Views
    6,775

    Finding Shorts

    Well Try this next time when you have a hard to find short . Take you a box of fuses and several tie in fuse holders . Place a fuse holder in each line going out of the ahu . Make sure the fuse is...
  47. Thread: True TDD4

    by rkious
    Replies
    19
    Views
    1,962

    old oil return ??

    Did you flush the system out before you installed the new compressor ? I have had systems before that had oil logged up in the evaporator from the failed compressor ( A lot!!) . Maby the oil...