Search:

Type: Posts; User: zootjeff

Search: Search took 0.00 seconds.

  1. Replies
    2
    Views
    2,086

    Online HVAC Training

    I'd like to get licensed and certified in residential hvac. Are there any good online certification programs recognized by states that are worth their weight in salt?
  2. Replies
    18
    Views
    2,368

    You need to get these "Consultants" to "show...

    You need to get these "Consultants" to "show their work" on this. If you don't have electric resistive AUX heat, you don't have a setback problem.
  3. Big problem with air-source is they often get...

    Big problem with air-source is they often get installed with electric backup heat. I think the industry is really lame for only promoting geothermal. Basically all you get is constant COP with a...
  4. Replies
    8
    Views
    4,931

    Geothermal and Backup heat

    Do most geothermal heat pump systems get installed with some kind of backup heat?

    What are the pro's and cons to sizing a geo heat pump so that you don't need backup heat?
  5. Replies
    25
    Views
    13,838

    Hey, it's been two years, what did you wind up...

    Hey, it's been two years, what did you wind up going with?

    I got a heatpump and I love it. I made a spreadsheet to compare the cost between Portland General and NW Natural Gas and I save money 6...
  6. What is the best way to clean an Electronic Air filter

    I'm sure this has been discussed before but I wanted peoples opinions on the best way to clean the electronic air filter cartridges. I have a Honeywell 20x20 F series. I put them the dishwasher...
  7. Replies
    33
    Views
    2,604

    I didn't have much luck with the Trane guy...

    I didn't have much luck with the Trane guy either. He said I needed a way oversized unit for my house (1900sq/ft home in Portland OR) and he was coming in around 8000 dollars for a 3.5 ton. I think...
  8. I hear you on the reducing the load. I think a...

    I hear you on the reducing the load. I think a better vented roof with heat reflective shingles is the best way to do that for my house at this point.

    Cool-n-save does look like an interesting...
  9. You mean the thread with the broken link to the...

    You mean the thread with the broken link to the video that it is based on? Can you tell me where to find that video? Or is it not relevant to the rest of the thread? I'll go back and read the rest...
  10. Ok, I got my answer. Thanks. Now I'm going to...

    Ok, I got my answer. Thanks. Now I'm going to beat a dead horse, feel free to comment or flame as appropriate.

    On the sprinkler circuit near my condenser, I could cap off the 3 sprinklers and on...
  11. That threat doesn't talk about sprinklers and the...

    That threat doesn't talk about sprinklers and the link to the avi in post 1 does not work.. Sprinklers are already installed, the question is if you use them, will it help?
  12. Does running sprinklers over condenser unit increase efficiency?

    I'm curious what people think about this idea. Swamp coolers work by running water over a mesh where air passes through and evaporative cooling causes the temperature of the resultant air to be...
  13. Can my furnace even support this AC Tonnage?

    I've had three contractors come out and quote systems for me. The first one said 2.5 tons, the second said 3 tons and the last said 3.5 tons. I looked at my furnace and I don't think it will support...
  14. Then why do they have two different wires E and...

    Then why do they have two different wires E and Aux to control W1 and W2 if they are going to fire at the same time? Seems like they'd just tell you to jumper it if it didn't somehow support the dual...
  15. That is what the Vpro 8000 claims to do. (It says...

    That is what the Vpro 8000 claims to do. (It says it's a 3H-2C t-stat) But the confusion comes in where it says it supports second stage emergency heat but is still calling it a 2H 1C. Meaning...
  16. Will the YTH9421 let you set the dead band? ...

    Will the YTH9421 let you set the dead band?

    Are you sure the Vpro8000 can't support the dual stage heating on the backup heat? Or do you mean you can't get manual control of both stages?

    After...
  17. Considering a Single-Stage Heat pump with AUX 2-stage heat

    I have an existing 2 stage gas furnace. I was thinking of just getting AC, but my contractor talked me into the benefits of getting a heat pump and it's not much more money..

    I like the idea of...
  18. Replies
    11
    Views
    941

    Considering a Goodman

    I'm thinking of getting a Goodman 3-ton heat pump unit over the Rheem unit.

    Can anyone give me a feel for whether or not it's worth it go for the scroll compressor. Looking at the datasheets they...
  19. Replies
    30
    Views
    2,748

    Lowest noise AC Condensers

    I'm looking at Trane, Goodman, Ruud, and Rheem.

    Who is going to have the least noisy compressor and fan? The only place to mount this is right outside my living room. I'm in the 3 ton range. If...
  20. Replies
    15
    Views
    3,075

    Most and Least reliable brands for AC

    Hi,

    I'm looking at getting central AC split system. I have a Trane furnace unit now, but I'm curious which brands are the most reliable.

    Consumer reports came out and said that Rheem, Ruud,...
  21. Yes I know I made a mistake. The ground temp is...

    Yes I know I made a mistake. The ground temp is 55 F. It gets to 90 F outside. Not 90 C. bla bla bla. The point of the post was lost in my typo..
  22. Geo Thermal Cooling Only, No compressor, will it work?

    I have been looking into geo thermal heat pumps and the options with vertical vs horizontal loops. If the ground is always 55 degrees F, then in theory you have 55 degree water coming in from the...
  23. Replies
    19
    Views
    2,955

    Yaa, Hence the disclaimer. I don't have AC. ...

    Yaa, Hence the disclaimer. I don't have AC. This works for me. Probably needs more thought to work for siggeorge
  24. Replies
    19
    Views
    2,955

    Ok, I took a video of it in action. ...

    Ok,



    I took a video of it in action. Basically all you have to do is install a switch that shorts the green wire to the yellow wire. When the short is there, the fan runs in high speed mode,...
  25. Replies
    2
    Views
    587

    I'm surprised that there is a market at all for...

    I'm surprised that there is a market at all for the 1 hose units! You'll get one cold room and a bunch of really warm rooms. Does anyone have a good list of two hose units?
  26. Replies
    19
    Views
    2,955

    Sounds like I solved the exact same problem you...

    Sounds like I solved the exact same problem you have..

    I have an XV90 and I put a toggle switch on my box to kick the circulation fan into high speed. I have a wood stove and I wanted more...
  27. Replies
    28
    Views
    1,575

    Ok, What if you don't use the full media...

    Ok,

    What if you don't use the full media filter in the second chamber, instead you use some carbon filter media? Then you get the odor removal of the ozone and various other contaminants and the...
  28. Pondering Question: Geo Thermal Compressorless cooling?

    I've been reading about geo thermal heat pumps, how they can get 27 SEER ratings, etc.

    But as the days have been getting up to 100 during the summer, and in the 70s at night. Couldn't you build a...
  29. Replies
    9
    Views
    615

    I pretty much figured out it is inches of water. ...

    I pretty much figured out it is inches of water. A reading of -0.3 on the inlet and a reading of 0.5 on the outlet would be an External Static Pressure reading of 0.8 where the units are inches of...
  30. Replies
    9
    Views
    615

    Would a copy of Mario Teaches Typing help? ...

    Would a copy of Mario Teaches Typing help? inches.water.gravity?

    I love guessing games.
  31. Replies
    28
    Views
    1,575

    Are you referring to me? I try to clean it every...

    Are you referring to me? I try to clean it every month. Sometimes every two months. Where did you get the idea I didn't want to clean my EAC??
  32. Replies
    28
    Views
    1,575

    Yes. That is what my professional installer did....

    Yes. That is what my professional installer did. Jacobs Heating and Cooling. Portland OR.

    The old furnace and the water heater were venting that way before.


    -Jeff
  33. Replies
    9
    Views
    615

    wc? Water column? Inches of water? Ok thanks.....

    wc? Water column? Inches of water? Ok thanks..


    -Jeff
  34. Replies
    9
    Views
    615

    Static Pressure, What are the units?

    I see lots of threads where people say the static pressure is 0.7 or 0.9 or x.

    Is this in terms of PSI? or some other unit?
  35. Replies
    5
    Views
    1,144

    That was from back in the Nixon Administration...

    That was from back in the Nixon Administration when they harnessed the methane of cows to supplement the natural gas....

    Actually I have no idea. The water heater is way old. It was like that when...
  36. Replies
    28
    Views
    1,575

    That would explain why dust still gets through my...

    That would explain why dust still gets through my EAC filter and gets sticks onto my furnace innards.


    What kind of solvents would you suggest to do a better job of cleaning the EAC?
  37. Replies
    28
    Views
    1,575

    Ok, so it is overkill, but it seems to be keeping...

    Ok, so it is overkill, but it seems to be keeping all the dust off the fan squirl cage and heat exchanger where the EAC alone did not. If it is working, then is my only problem that I have my fan...
  38. Replies
    28
    Views
    1,575

    There are several problems with putting the EAC...

    There are several problems with putting the EAC after the Media filter.

    #1 Cost. The EAC is easy to wash and doesn't cost anything to maintain every couple months. Putting the other one first...
  39. Replies
    28
    Views
    1,575

    Deleted post.

    Deleted post.
  40. Replies
    28
    Views
    1,575

    I know it's not the same as the AprilAire, but it...

    I know it's not the same as the AprilAire, but it is similar.

    There are several problems with putting the EAC after the Media filter.

    #1 Cost. The EAC is easy to wash and doesn't cost anything...
  41. Replies
    28
    Views
    1,575

    It is not a pre-filter, it is a post filter. It...

    It is not a pre-filter, it is a post filter. It goes like this:

    3/8" metal mesh pre-filter--> Electronic Filter cartridge --> Media Post Filter --> Furnace.

    I got the idea from looking at the...
  42. Replies
    28
    Views
    1,575

    The dust accumulates over 60 days of general use....

    The dust accumulates over 60 days of general use. After blowing out the fan squirrel cage housing with a compressor, you reach in and rub your finger on it and it is clean. 60 days later, you take...
  43. Replies
    5
    Views
    1,144

    Old Plenum Repair Advice

    I lost a key to my truck along side the plenum on my 1973 home. They actually poured the slab for the garage around the plenum. The base plenum is 26 by 26 by 32 inches and it supports the furnace.
    ...
  44. Replies
    28
    Views
    1,575

    The filter is brand new. It's not really a lot of...

    The filter is brand new. It's not really a lot of dust, but dust none the less. When the unit comes on, it detects the airflow before energizing the plates. As that initial airflow goes by it knocks...
  45. Replies
    28
    Views
    1,575

    Is this Filter Assembly Reasonable?

    I was wondering anyone has done anything like this for air filtering. In a retrofit downflow system, the electronic F300 will still leak tons of dust into the heat exchanger and blower of the...