  1. Thread: sight glass

    by BigBacardi
    Replies
    51
    Views
    4,732

    prime example of flashing is lo fire on a 2 stage...

    prime example of flashing is lo fire on a 2 stage compressor
    bubbles are normally present on lo fire.
    charging by sight glass is crazy for resi ac/hp
  2. Replies
    4
    Views
    406

    looking for dealer in canada

    looking for dealer in canada
  3. Replies
    4
    Views
    406

    Buderus Boilers

    Where in the world does one go to find a wholesaler for parts?
    WWG/Totaline no longer carries the brand.
    I have spent hours looking online and making calls
    Am I really this stoopid???
  4. Replies
    101
    Views
    6,697

    ahhh yes...remember the good ole days..........

    ahhh yes...remember the good ole days.......
    charge to 70 lbs on a hoy day, and beer can cold!

    system works purrrrrfect!!!!
  5. Haven't been here for awhile Forgot how good...

    Haven't been here for awhile
    Forgot how good info is

    Omg after 1.2 minutes I found the answer on removing broken schrader valve!!!

    Over 15 yrs in trade and finally broke my first one!!!!
  6. Replies
    14
    Views
    2,424

    high contactor open means bristol recip comp. u...

    high contactor open means bristol recip comp.
    u say only one contactor, which means copeland scroll.

    something is really messed up
  7. Replies
    11
    Views
    1,266

    80% furnace is not power vented it is induced...

    80% furnace is not power vented
    it is induced draft
    the inducer motors job is just that....induce a draft
    if u put manometer 18" downstream of furnace exhaust u will find vacuum, not pressure
  8. Replies
    25
    Views
    2,359

    lol pretty sure no matter what u do it will not...

    lol
    pretty sure no matter what u do it will not be good enuf for him....say goodbye and wash your hands of him....

    if not...repost in six months and let me know!!!!!
  9. carrier EZ FLEX fi;ter only way to go in my...

    carrier EZ FLEX fi;ter only way to go in my opinion
  10. Replies
    6
    Views
    954

    was just at a seminar...... dont remember the guy...

    was just at a seminar...... dont remember the guy saying that could vent 2 apliances tho......
  11. Replies
    61
    Views
    5,445

    been there, you stated earlier that in a 2 stage...

    been there, you stated earlier that in a 2 stage furnace the inducer doesnt slow down enuf????? and to much excess air.....am curious, cause all 2 stage furnaces have 2 stage inducer motors, wouldnt...
  12. Replies
    44
    Views
    5,035

    as far as liability goes, turn off gas cock and...

    as far as liability goes, turn off gas cock and power switch. make note on work order that furnace not safe to operate. when u leave and homeowner turns gas cock and power on....not your...
  13. Replies
    44
    Views
    5,035

    pic taken from 8 yr old bryant 340AAV042080348261

    pic taken from 8 yr old bryant 340AAV042080348261
  14. lol...had this happen to me once... on a maytag...

    lol...had this happen to me once... on a maytag mid.....the old tstat was lunched.....and dropping signal as ignitor was on...hence no fault code!!!!! it drove me nuts till i tried to jump furnace...
  15. Replies
    61
    Views
    5,445

    pressure correction factor .....if you have...

    pressure correction factor .....if you have anything above lo pressure...14 inches than a pressure correction factor must be performed. standard clocking tables are made with lo pressure data.
  16. Replies
    61
    Views
    5,445

    curious....you said you clocked furnace....u have...

    curious....you said you clocked furnace....u have lo pressure gas...or 2 lb?????

    if you have 2 lb did you forget to make allowance for pressure allowance of xxxxxx?

    cause if you forget pressure...
  17. Replies
    72
    Views
    9,427

    the solution is to just replace the parts that u...

    the solution is to just replace the parts that u havent done yet...... eventually u will fix problem
  18. Replies
    20
    Views
    1,207

    what were choices for answers? and zero...

    what were choices for answers?

    and zero energy???? me thinks impossible?
  19. Replies
    9
    Views
    1,482

    LOL u went back and corrected the situation...

    LOL u went back and corrected the situation tho...right?
  20. Replies
    9
    Views
    1,482

    Hot air coming from Return Air Ducting?

    So i got a phone call from a buddy today....A friend of a friend asked me to do a retrofit(on the side)

    I dont mind making a shwack load of cash in a short period of time. As dont have any...
  21. Replies
    30
    Views
    4,548

    i remember my first time with a problem...

    i remember my first time with a problem similar....the disc was so rotten that it wasnt there. i was pulling my hair outa head untill some other guy said that the opening should be 1.5 inches.....i...
  22. plugged...maybe.....corroded and comprimised...

    plugged...maybe.....corroded and comprimised absolutely....furnace is done son.
  23. Replies
    13
    Views
    2,310

    mr bill...... after 14thousand posts......the red...

    mr bill...... after 14thousand posts......the red wire????? and the white wire?????

    OMFG......

    im in trouble cause i only got a white and a black wire.....I dunno whAT to do?
  24. Replies
    14
    Views
    1,697

    and...golden rule.... never ever ever...zone...

    and...golden rule....

    never ever ever...zone single stage equipment....no matter the size
  25. Replies
    7
    Views
    998

    why???? when you go to dr...does he show you...

    why????


    when you go to dr...does he show you a book of what is wrong with you????

    if you customer doesnot believe you then you have done a piss poor job.

    you do not need to explain to them...
  26. Replies
    14
    Views
    1,697

    try using the carrier infinity zoning.....they...

    try using the carrier infinity zoning.....they got that shat right!!!!
  27. Replies
    17
    Views
    2,140

    went for an ac tuneup earlier this year...went to...

    went for an ac tuneup earlier this year...went to stat and called fort cool...went outside to see if cond running...nope...huh....went inside to check furnace switch....its on...but wait ...no...
  28. Replies
    14
    Views
    2,310

    ok so we have decided that it has a warp switch....

    ok so we have decided that it has a warp switch.

    if it has a warp switch, than it has a cracked htx.....have yet to come across carrier with warp switch that didnt have cracked htx....
  29. Replies
    8
    Views
    1,175

    been dealing with this for several years up in...

    been dealing with this for several years up in canada. can honestly say still have never ever run intosituation where i cant vent.

    a lot of time owners pissed about location.....but not my...
  30. Replies
    19
    Views
    3,227

    next question.... why do you not have a blower...

    next question....

    why do you not have a blower cap on your truck????
  31. not sure of carrier model # do know bryant...

    not sure of carrier model #

    do know bryant tho....and if your heatpump has ecm fan motor....then no it will not work.

    although several heat pumps have the same infinity board, options are...
  32. Replies
    38
    Views
    3,856

    just curious if you cannot pump back into...

    just curious if you cannot pump back into microchannel coil.....do they all come dryship? how does the mfg put charge into unit?
  33. Replies
    31
    Views
    4,038

    hey dandyme..... i love your signature.... im...

    hey dandyme..... i love your signature....

    im also thinking the OP should have read it before posting a loaded question

    the OP deserves all the barrage coming for asking a question like that.
  34. Replies
    12
    Views
    2,115

    have you verified that the burners are properly...

    have you verified that the burners are properly aligned with the openings?
  35. Replies
    29
    Views
    3,720

    its not heat that cannot be destoyed. the...

    its not heat that cannot be destoyed.

    the actual statement is...energy can not be created nor destroyed, its state can only be changed
  36. Replies
    93
    Views
    12,747

    omg but what if i dont have abrown or purple...

    omg


    but what if i dont have abrown or purple wire?
  37. size of suction line?

    size of suction line?
  38. i am fairly well versed in infinity zone systems....

    i am fairly well versed in infinity zone systems.

    the installer should be shot.

    u cant have a 600 sqfoot room as on zone on a 5 ton 2 stage hp....cause first stage is almost 40kbtu!!!!

    of...
  39. Replies
    63
    Views
    6,510

    im thinking the flux capacitor is upside down....

    im thinking the flux capacitor is upside down. also Ltry changing wires from L1 and L2 to each iother side of contractor.reverse phase is always a possibllity in the fall
  40. Replies
    17
    Views
    1,973

    non condensibles

    non condensibles
  41. Replies
    14
    Views
    1,679

    metal ladders? i use a double sided metal...

    metal ladders?

    i use a double sided metal ladder made from falcon ind. in canada.....best ladder ever built, mine is 15 yrs old and still going strong!!!!
  42. Thread: Rwilli

    by BigBacardi
    Replies
    3
    Views
    698

    ity willnot damage compressor....

    ity willnot damage compressor....
  43. Replies
    35
    Views
    5,298

    so i find out it was just roughed in at furnace...

    so i find out it was just roughed in at furnace room. but homeowner never paid to have condensor in stalled...

    funny thing is.....r22 evap coil.....hahahahahaha....paid for coil, but now its gonna...
  44. Replies
    35
    Views
    5,298

    Please Fix My AC

    I get a call last week:

    Its effin hot in here...please come fix my ac!!!

    OK...I show up, tstat on cool....go down stairs....furnace fan is on....cased coil looks alright.....lines brazed up...
  45. Replies
    6
    Views
    795

    ouch.... a little jaded are we??? lol

    ouch.... a little jaded are we???


    lol
  46. Replies
    33
    Views
    2,480

    carrier does have a subcooling slide...

    carrier does have a subcooling slide calculator....but if you need a calculator to figure out subcooling.....maybe...ahem....a little more training is in order
  47. Replies
    5
    Views
    992

    3 ft from any source of ignition....ie...

    3 ft from any source of ignition....ie motor....contactors....
  48. Thread: gauges

    by BigBacardi
    Replies
    26
    Views
    1,999

    u not gonna kill your hoses by leaving 410 in...

    u not gonna kill your hoses by leaving 410 in them....period
  49. Thread: 2nd opinion

    by BigBacardi
    Replies
    16
    Views
    1,366

    how is oat 85 and rat 63 even reasonable testing...

    how is oat 85 and rat 63 even reasonable testing parameters? me thinkx u got a couple poor readings....
  50. Replies
    18
    Views
    2,231

    would a 5 psi "bounce" on the discharge side also...

    would a 5 psi "bounce" on the discharge side also indicate non-condensibles in system.
    assuming its r22 and working sort of ok....and always there.