Search:

Type: Posts; User: hvac69

Page 1 of 20 1 2 3 4

Search: Search took 0.03 seconds.

  1. Some crazy stuff, I seen this story a few weeks...

    Some crazy stuff, I seen this story a few weeks ago. I like the one comment on the original story page about this being his bill collection team.
  2. Thread: Our Ice Bar

    by hvac69
    Replies
    14
    Views
    356

    I like the idea of the larger area over a rail...

    I like the idea of the larger area over a rail due to it being able to hold pitchers as well.
  3. Thread: Our Ice Bar

    by hvac69
    Replies
    14
    Views
    356

    How do you deal with it making my wings cold as I...

    How do you deal with it making my wings cold as I sit there enjoying a nicely chilled beverage?
  4. Not positive but I think it has to do with...

    Not positive but I think it has to do with revision. I did find something stating that the XP19102-8304 replaces the 8204. There was also a 8004 at one time as well.
  5. Replies
    16
    Views
    333

    That lists what each motor and compressor is...

    That lists what each motor and compressor is rated at. Probably listed as per circuit. 110 amp max fuse size.
  6. Replies
    19
    Views
    435

    Thank you. Don't know if I am looking at the...

    Thank you. Don't know if I am looking at the correct drive with the numbers posted but what I did find is a TR1 6027 is rated at 25 HP and max output @ 230 V is 78.2 amps. But that doesn't even match...
  7. Replies
    19
    Views
    435

    Is that unit 208/230 or 480 3 phase? 30 HP 480 3...

    Is that unit 208/230 or 480 3 phase? 30 HP 480 3 Phase motor should be around 40 FLA and 80 amps @ 230. If the unit is 480 that drive will be fine, I have seen it done on other manufacturers, I...
  8. Replies
    5
    Views
    204

    That had to have been typed on a not so smart...

    That had to have been typed on a not so smart phone. Call a service company.
  9. Thread: Holiday Pay

    by hvac69
    Replies
    50
    Views
    1,219

    I worked for a company that OT was strictly over...

    I worked for a company that OT was strictly over 40 only and , holiday, vacation and sick pay did not count towards the 40. So if I worked a holiday I would not get paid OT. Found that out after...
  10. Thread: Holiday Pay

    by hvac69
    Replies
    50
    Views
    1,219

    That is messed up and like you said they must...

    That is messed up and like you said they must have made a mistake or they are really messed up. You wouldn't catch me working holidays then. We get OT after 8 on any day Monday to Friday, on holidays...
  11. Not knowing whether or not the chillers support...

    Not knowing whether or not the chillers support either LON or BACnet directly I would not say one is better than the other. If they support one or the other protocol directly that would be an...
  12. Replies
    8
    Views
    145

    Did you bind the points?

    Did you bind the points?
  13. Thread: VykonPRO module

    by hvac69
    Replies
    34
    Views
    5,271

    I used to have access to it but a year ago went...

    I used to have access to it but a year ago went WEBs only. What is the latest version, the last I used was version 3.54.
  14. Replies
    1
    Views
    147

    No, one is a sensor the the other is a thermostat.

    No, one is a sensor the the other is a thermostat.
  15. Replies
    4
    Views
    153

    Looks like the 374 would be the replacement.

    Looks like the 374 would be the replacement.
  16. Replies
    4
    Views
    153

    http://tekmarcontrols.com/images/_literature/d9029...

    http://tekmarcontrols.com/images/_literature/d9029_01.pdf

    Just a heads up I found it here link and searched for reset, showed up as discontinued.
  17. Replies
    4
    Views
    242

    Look through the plenum opening, filtered...

    Look through the plenum opening, filtered opening, if you can see the damper from the air system it is series, if all you see is a blower assembly its parallel.
  18. Thread: Fire dampers

    by hvac69
    Replies
    11
    Views
    464

    The only ones I have seen were linear slot...

    The only ones I have seen were linear slot diffuser plenums with lead links holding a flap up, think they were Tranes but that was years ago. Could easily see if they were open by looking upward.
    ...
  19. Replies
    20
    Views
    1,799

    I used to do start up for a sheet metal...

    I used to do start up for a sheet metal contractor and during start up I had airflow issues on a unit. Balancer was on site, they told me they had balanced the unit yesterday. I go up in the ceiling...
  20. Replies
    17
    Views
    1,591

    What is that old beast?

    What is that old beast?
  21. Replies
    10
    Views
    1,174

    How many years did it take to get like this? I...

    How many years did it take to get like this? I have no faith in property or township inspectors, there are turds everywhere, after some of the crap I found in the house I bought a few years later....
  22. Set them as conventional/gas heat.

    Set them as conventional/gas heat.
  23. Replies
    9
    Views
    408

    Air rotation unit.

    Air rotation unit.
  24. Replies
    29
    Views
    2,229

    Yes I could have taken the term condemn out of...

    Yes I could have taken the term condemn out of context and sometimes its out of what I have personally seen techs condemn equipment over. But in by no means would I have left that thing running and...
  25. Replies
    29
    Views
    2,229

    As stated elsewhere if it works, is safe why...

    As stated elsewhere if it works, is safe why condemn over a pilot unless the flash of a commission gleams in the eye. It may be inefficient but that is no reason to condemn just an opportunity to...
  26. Vague description, was it the size of a brick and...

    Vague description, was it the size of a brick and tan and brown, no label on the back of it? Possibly T7300?
  27. Replies
    26
    Views
    1,547

    That isn't even an entry level position in HVAC...

    That isn't even an entry level position in HVAC trade and they are as far from being a HVAC contractor as you can get. That is downright BS. Look elsewhere and quickly.
  28. Replies
    4
    Views
    236

    The user manual and install manual have different...

    The user manual and install manual have different ways to get to the configuration screen, possibly some are not available in user access. How did enter the config screen?
  29. Replies
    4
    Views
    236

    http://siglercommercial.com/wp-content/uploads/201...

    http://siglercommercial.com/wp-content/uploads/2013/04/CARRIER_EDGE_PRO_THERMOSTAT_INSTALL.pdf

    Page 6 and 7
  30. Thread: Carrier RTUs

    by hvac69
    Replies
    8
    Views
    413

    Configuration like addressing can not be done...

    Configuration like addressing can not be done with the driver. There are other configurations that cant be discovered as well.
  31. Thread: Carrier RTUs

    by hvac69
    Replies
    8
    Views
    413

    If the units are CCN capable yes you can. What...

    If the units are CCN capable yes you can. What kind of stats?
  32. Replies
    15
    Views
    985

    I am assuming you are referring to JACE products....

    I am assuming you are referring to JACE products. There is no difference between Vykon and Easy IO Jace devices except for branding. Not sure of Easy IO is open licensed out of the box or if an...
  33. Thread: Reflok tool

    by hvac69
    Replies
    23
    Views
    1,069

    Reflok uses aluminum not copper. Your link does...

    Reflok uses aluminum not copper. Your link does not work but I have seen the videos. My issue with any of the one time mechanical fittings whether it be refrigeration or plumbing is the additional...
  34. Any idea of brand?

    Any idea of brand?
  35. Thread: ax px ?

    by hvac69
    Replies
    2
    Views
    204

    Value binding would be an additional ord added to...

    Value binding would be an additional ord added to bound label used to animate something like the background of the bound label and the bound label would show the value of the ord for example. But in...
  36. From what I remember Reznor is something in the...

    From what I remember Reznor is something in the range of 40 to 75 rise and the 240 limit sounds high.
  37. Outdoor lockout setpoint set incorrect. Outdoor...

    Outdoor lockout setpoint set incorrect. Outdoor temp sensor not reading correctly, locking out heat. AHU in either morning or day warmup and the unit not heating. What are the VAV dampers doing,...
  38. Replies
    80
    Views
    3,244

    Every time I heard a tech say I had a bad flame...

    Every time I heard a tech say I had a bad flame rod my blood pressure goes up. What do you mean bad, broken, melted, corroded? No just didn't work... WTF I dont how many times I was back on that roof...
  39. Replies
    8
    Views
    1,008

    HGBP constantly powered by the same source as the...

    HGBP constantly powered by the same source as the compressor contactor may prevent pump down.
  40. Replies
    1
    Views
    275

    I sent you private message

    I sent you private message
  41. Replies
    46
    Views
    2,270

    I have seen these in a few instances. Nice solid...

    I have seen these in a few instances. Nice solid connections. http://www.grainger.com/product/IDEAL-Wire-Connector-6VG14
  42. Replies
    33
    Views
    3,794

    Looks like the condenser is sitting directly on...

    Looks like the condenser is sitting directly on top of the chiller as well with no extra support. The single block of wood under the 20 ft seal tite snake is a nice touch, why even bother?
  43. Not sure what kind of issues would arise from...

    Not sure what kind of issues would arise from refrigerant flowing through receiver in reverse during heating mode. Trapping oil is one I can think of immediately.
  44. If he is using refrigerant and not certified...

    If he is using refrigerant and not certified where is he getting the refrigerant? Call the EPA they would be curious as well. I wouldn't fix anything for free. If he cant understand that let it be...
  45. Are the reheats working? Does not seem to be when...

    Are the reheats working? Does not seem to be when your discharge air setpoint is 58 and the rooms are 61 and 66

    Lower the discharge air setpoint and the let the reheats control the room...
  46. Thread: Job offer i got

    by hvac69
    Replies
    16
    Views
    1,738

    They contacted you, so apparently they need...

    They contacted you, so apparently they need workers. There was something in your resume that had their attention long enough to contact you but are not willing to pay you more hourly and will only...
  47. Replies
    4
    Views
    234

    The last economite I seen was probably 20 years...

    The last economite I seen was probably 20 years ago. Amazing how long the old stuff lasts.
  48. Replies
    2
    Views
    260

    Add it as a dynamic device and dont even attempt...

    Add it as a dynamic device and dont even attempt to install spyder tools on the jace.
  49. I was thinking earlier manufacturing date.

    I was thinking earlier manufacturing date.
  50. Software version 4.0 or greater only.

    Software version 4.0 or greater only.
Results 1 to 50 of 1000