  1. Connecting to a Trane VariTrac Central Control Panel?

    Looking for some info on connecting to an older trane VariTrac central controller. I have a older version of rover but I believe this controller might run through hyper terminal. Also looking for the...
  2. Replies
    2
    Views
    113

    JCI FX-PCT Issue

    I'm trying to commission a new FX-PCG2611-0 but when I try to connect it it through the PCT Tool im getting a error message "The selected file cannot be opened due to a formatting or tool...
  3. Replies
    51
    Views
    5,828

    530721

    530721
  4. Replies
    51
    Views
    5,828

    It's common with all these style boilers, they...

    It's common with all these style boilers, they run off priority demand and DHW is always priority #1.
  5. Boston train is union.

    Boston train is union.
  6. Yea I'm currently in the union.

    Yea I'm currently in the union.
  7. Replies
    30
    Views
    944

    Stop dicking around and get the correct motor.

    Stop dicking around and get the correct motor.
  8. Thinking about switching contractors.

    I currently work for a large mechanical contractor and received a job offer from our local Trane Office. At the company I currently work for I do about 50% controls and 50% commercial mechanical...
  9. Disconnect the heating relay and safeties, then...

    Disconnect the heating relay and safeties, then turn the system to heat and see if it trips.
  10. I don't think it really comes down to throw, it's...

    I don't think it really comes down to throw, it's more about proper sizing using BTUs, Square Footage, and heat loads.
  11. Replies
    22
    Views
    1,373

    No it's actually a fire station in RI.

    No it's actually a fire station in RI.
  12. Replies
    22
    Views
    1,373

    Ugly controls cabinet

    The mechanical contracting company I work for recently took over a new account. I went out there today to do a review of the BMS and found multiple panels like this. This is pretty much a brand new...
  13. Replies
    22
    Views
    2,103

    Is that a Multistack?

    Is that a Multistack?
  14. Trane BACnet RTU BCI-R Board Help.

    Yea I have that literature, it doesn't show the bacnet connections.521271
  15. Trane BACnet RTU BCI-R Board Help.

    Looking for some help with bacnet mstp wiring regarding the Trane BACnet RTU BCI-R Board. In the literature it doesn't really explain which terminals are for the comm wire. I included a photo of the...
  16. JCI FX30 Help!! "loading lexicon list" Stall

    Im trying to connect to a new FX30. Ive loaded the updates into the 30 via work bench and im able to connect to the 30 with my laptop but when using the customers older laptop the FX30 starts to boot...
  17. Norlake CB0751C-A Walk-in Half Evap Frosting?

    Working on a Norlake CB0751C-A Walk-in and while the system is running only half the evaporator is frosting up. It's a TXV R22 style system, I've weighted in the correct charge and checked superheat....
  18. Replies
    16
    Views
    979

    I'm union so the hiring process is a little...

    I'm union so the hiring process is a little different.
  19. Replies
    16
    Views
    979

    Idk where you stand with schooling and training...

    Idk where you stand with schooling and training but Local 777 out of Meriden CT how's a really good apprentice program.
  20. Replies
    16
    Views
    979

    Yea I'm in RI and trane is a union only shop here...

    Yea I'm in RI and trane is a union only shop here also the same in Boston but your rite the CT branch is non-union.
  21. Replies
    16
    Views
    979

    I worked for trane for 4 years, it all depends on...

    I worked for trane for 4 years, it all depends on your skill set. Some guys at trane work on RTUs, AHUs, Fan Coils, exc. other guys like myself work on only chillers.
  22. Replies
    16
    Views
    979

    Some Trane branches union shops, so transferring...

    Some Trane branches union shops, so transferring could get tricky.
  23. Replies
    18
    Views
    1,354

    Non condensables possibly?

    Non condensables possibly?
  24. Replies
    18
    Views
    929

    Is it a glycol system?

    Is it a glycol system?
  25. Replies
    29
    Views
    1,519

    Controls Cabinet Laptop Stand.

    I've seen a lot of guys in the field make their own custom cabinet laptop holders. Just wondering what's out there and if anyone has any advice on where to buy one or how to make one? Thanks
  26. Installing AC with a two zone gas furnace.

    Looked at a small job last night, 80k BTU gas furnace with 2 zones and honeywell zone dampers and a 3 ton coil in place. Are there any precautions with air flow and zone dampers for central air?
  27. Replies
    15
    Views
    830

    You don't need any type of converters, if the...

    You don't need any type of converters, if the chillers have a ccn card you connect between that and the standard RS-485 on the jace. What you will need to purchase is the ccn license for your local...
  28. Replies
    28
    Views
    1,467

    Buy a system online and install it but don't call...

    Buy a system online and install it but don't call us looking for help.
  29. Replies
    1
    Views
    332

    KMC Controls?

    Has anyone had any experience with KMC controls? I mainly do JCI but the company I work for is trying to pick up a new school district with KMC controls. Is the system propriety? The schools have...
  30. Replies
    4
    Views
    291

    What about in hand? I've tried running it through...

    What about in hand? I've tried running it through in hand mode and I'm still not getting any lights.
  31. Replies
    4
    Views
    291

    Siemens/Powers issue

    I'm working on a older Siemens/Powers system and I'm having an issue with the analog output module. I've included some photos, should the AO module alway be lit up?500521500531
  32. Replies
    15
    Views
    830

    Last summer I brought on two carrier screw...

    Last summer I brought on two carrier screw chiller onto a FX70. It was pretty straight forward, just purchased the proper CCN license for the FX70 and wired into the RS485. Once everything was all...
  33. Replies
    5
    Views
    402

    Might be worth trying to slim up the DMO file and...

    Might be worth trying to slim up the DMO file and only import the points your going to use.
  34. Replies
    51
    Views
    5,828

    Well I guess that's just a personal preference....

    Well I guess that's just a personal preference. I've never experienced anything like that with propress, as long as it's been properly preped and fitted. The company I work for did a 20 million...
  35. Replies
    51
    Views
    5,828

    What's wrong with the propress and zone valves?

    What's wrong with the propress and zone valves?
  36. Advice on easy to set up small BAS system

    There's a lot of programing going on here, definitely not a good project to get your feet wet on. A good place to start would be to sit down and generate a points list for each piece of equipment....
  37. Replies
    51
    Views
    5,828

    I've used the the navien header beside, not...

    I've used the the navien header beside, not really a fan of it plus it didn't really fit this application.
  38. Replies
    51
    Views
    5,828

    Yea here's the finished product. 470341

    Yea here's the finished product. 470341
  39. Replies
    51
    Views
    5,828

    Yes

    Yes
  40. Replies
    51
    Views
    5,828

    Navien Boiler install

    Navien Boiler install, not 100% done but pretty close. 468201
  41. Replies
    5
    Views
    506

    So your looking to bring mulitple FX-70s onto one...

    So your looking to bring mulitple FX-70s onto one central location via a FX-Server?
  42. Replies
    8
    Views
    566

    If the controllers themselves were going on and...

    If the controllers themselves were going on and offline I would say that's a common problem I've seen often, but the controllers are stable. It's the points themselves within the controllers at are...
  43. Replies
    8
    Views
    566

    My email is alliedtech12887@yahoo.com Thanks

    My email is alliedtech12887@yahoo.com
    Thanks
  44. Replies
    8
    Views
    566

    I also just checked my version of HVACPro and im...

    I also just checked my version of HVACPro and im running 8.08, where can i locate HVACpro 8.08b?
  45. Replies
    8
    Views
    566

    Okay thanks ill have to look it to that.

    Okay thanks ill have to look it to that.
  46. Replies
    8
    Views
    566

    Point Faults on JCI FX-60

    I have a building with a FX-60 and two trunks of N2 VMA's and DX's. There are about 50 devices per trunk. The issuse im having is that the points themselves keep going offline and into fault, FX60...
  47. Replies
    1
    Views
    302

    Honeywell Webbs 600 Login Issues

    Recently got a new account with a Honeywell Webb 600 and some Honeywell Spyder controls. The previous contractor changed the default admin password and would not release it to the custemor. Is there...
  48. Honeywell Spyder Programing and Service Tool question.

    Recently started servicing a new account with lon honeywell spyder. Just looking for availability on the service tool and programing software.
  49. Replies
    1
    Views
    292

    JCI FX-60 comm issues

    Received a call last week from a customer that was having issues connecting to their FX60 we installed 3 years ago. When I arrived on site I noticed there has no heart beat on the 60 and attempted to...
  50. Weil McLain LGB4 Steam Pressure Settings?

    The mechanical contractor I work for recently install a couple of Weil McLain LGB4 Steam Boilers all at different locations. I'm a little rusty when it comes to steam and couldn't find anything in...
Results 1 to 50 of 166