  1. Replies
    16
    Views
    1,300

    The architect and customer preferred this wiring ...

    The architect and customer preferred this wiring
    scenerio because it is a datacenter if NCM or DX
    goes down they want local control.

    The first thing I thought was the AI to AO scenerio
    but...
  2. Replies
    24
    Views
    4,845

    lenb: Check your email for further...

    lenb:



    Check your email for further instructions.
  3. Replies
    24
    Views
    4,845

    When you run that patch it will upgrade you ...

    When you run that patch it will upgrade you
    from 8.07 to 8.08B. You do not need anything else.
  4. Replies
    24
    Views
    4,845

    lenb: Check your email.......

    lenb:


    Check your email.......
  5. Replies
    16
    Views
    1,300

    1 DA sensor and 2 DX-9100

    Have 2 fans and 2 DX-9100 controllers.
    The fans go to a common duct.
    They have separate discharge sensors.
    If I installed a 4-20ma discharge sensor
    in common duct, can I wire it to both DX-9100?...
  6. Thread: NCM Demon??

    by d_d_c_jci
    Replies
    23
    Views
    1,191

    Usually on the blue screen, you single click on...

    Usually on the blue screen, you single click on the system
    that the processes have been programmed for (AHU1, 1stfloor,etc)
    It depends where they created the processes in Metasys.
    , then on bar on...
  7. Replies
    7
    Views
    772

    The only thing I know of for DX power failures is...

    The only thing I know of for DX power failures is below:

    Is there a program for DX power failures?

    Cause:

    Solution:
    See the Pwrfail.exe and Reset.exe files located in the DX-9100 Tools...
  8. Thread: N30 Error

    by d_d_c_jci
    Replies
    17
    Views
    1,500

    Have you tried to connect with hyperterminal?

    Have you tried to connect with hyperterminal?
  9. Thread: NCM Demon??

    by d_d_c_jci
    Replies
    23
    Views
    1,191

    Sounds like GPL is using an Analog Data point to...

    Sounds like GPL is using an Analog Data point to write
    the setpoint in CS object.
    Go to processes in Metasys and see if there is a process called
    setpoints or something like that.
    If GPL files...
  10. Replies
    4
    Views
    740

    OK...but what about from the server. I cannot...

    OK...but what about from the server.

    I cannot look or modify the program from
    the server if it wasn't in Visuallogic?
  11. Replies
    4
    Views
    740

    Alerton programming

    I have a school district with Envision for Bactalk on a server.
    Each school has at least 1 TUX, ETH, etc.
    The field controllers vary because they were installed
    when they had IBEX.
    I know I can...
  12. Replies
    24
    Views
    4,845

    Here you go....

    Here you go....
  13. Replies
    13
    Views
    1,067

    Thanks again for your responses.... I will get...

    Thanks again for your responses....
    I will get pricing tomorrow on MP580
    Can it be programmed through a Summit workstation?
    I have Lonmaker but if I can use the workstation
    it would be better.
  14. Replies
    13
    Views
    1,067

    No Lon, Only Comm3, Comm4, and Comm5 on BCU. ...

    No Lon,

    Only Comm3, Comm4, and Comm5 on BCU.

    MP581 might be too much.

    This is the reason why I thought UPCM and now
    you guys just reinforced my thoughts.
  15. Replies
    13
    Views
    1,067

    Boiler controls

    What Trane controller is best for turning boilers
    on-off and controlling secondary valve?
    Would it be UPCM?
    We have Trane Summit BCU with workstation.
  16. Replies
    4
    Views
    553

    How do I find / modify the IP address for Summit?

    How do I find / modify the IP address for Summit?
  17. Replies
    4
    Views
    553

    N31 integration

    Has anyone tried to bring the N31 into Tracer Summit
    as BACNET/IP?
    How hard is it?
    Is there a point limit?
  18. Replies
    12
    Views
    898

    Your HVACPRO settings are fine. You need to...

    Your HVACPRO settings are fine.

    You need to change your jumper on your actuator to
    reverse-acting. But make sure when you lose
    power to the actuator it spring returns open.
  19. Replies
    11
    Views
    7,724

    NAE and NCE are different controllers so THERE IS...

    NAE and NCE are different controllers so THERE IS NOT a NAE25.
  20. Replies
    11
    Views
    7,724

    There is no NAE25, only 35,45, and 55. Anyways,...

    There is no NAE25, only 35,45, and 55.
    Anyways, there is no simple way to reset passwords
    without blowing the database away. (N.U.T. the NAE)
    Then reloading it.
    Are you sure you typed in the...
  21. Replies
    3
    Views
    541

    Yeah, but the problem is when maintenance turns...

    Yeah, but the problem is when maintenance turns the
    univent off to change filters the command from the n30
    goes away and defaults to summer until the master is toggled.
  22. Replies
    3
    Views
    541

    N30 Interlock

    Have some univents with UNTs
    that has sum-win binary input
    I am using the N30 master sum-win
    to override these inputs.
    When univents lose power and come back
    on, they default to summer because...
  23. Thread: NAE graphics

    by d_d_c_jci
    Replies
    3
    Views
    862

    NAE graphics

    Does anyone have RTU, MAU, and VAV w/electric heat
    graphics that they can share?
    Either standard or advanced.
  24. Thread: Dectron

    by d_d_c_jci
    Replies
    12
    Views
    2,959

    Dectron

    Has anyone tried to integrate into a Dectron
    unit that has a Siemens OP393 III PLC controller?

    Anyone know what the controller's protocol is?
  25. Replies
    7
    Views
    993

    gbfromsd NO...why?

    gbfromsd


    NO...why?
  26. Replies
    7
    Views
    993

    Mackinaw You have mail......

    Mackinaw

    You have mail......
  27. Replies
    7
    Views
    993

    I found it and I cannot attach, what is your...

    I found it and I cannot attach, what is your email?
  28. Replies
    7
    Views
    1,073

    You should be able to get the fieldserver already...

    You should be able to get the fieldserver already programmed.
    I do have a .csv file but I have to look for it.
    It is Ingersol modbus to N2 I believe so I don't know
    if it will help.
  29. Replies
    7
    Views
    993

    JCI FEC Sideloop

    Does anyone know or have an example of
    a sideloop that uses an input (fan status)
    to turn the PID state to OFF or control?

    Also, using summer /winter status to change output
    from Direct Acting...
  30. Replies
    9
    Views
    1,551

    I think the issue was it was performing a...

    I think the issue was it was performing a recalibrate
    at the same time mourning warmup was active and
    therefore overheating classrooms.
    I set the schedule for 2:00am to 2:15am.
    Been like this for...
  31. Replies
    7
    Views
    930

    First, check to see if the jumpers on the back ...

    First, check to see if the jumpers on the back
    of the DX-9100 are correct.
    Check the program to see if defined and ranges are correct.
    Check wiring:
    one blue and one orange on 15vdc terminal of...
  32. Sorry, I just seen where you stated The circ....

    Sorry, I just seen where you stated The circ. pump is
    running and there is proof of run status but you have a
    no flow alarm. Do you have a point that states the
    pump status is ON, well what...
  33. http://cgproducts.johnsoncontrols.com/default.aspx...

    http://cgproducts.johnsoncontrols.com/default.aspx?main.aspx&2
    ...
  34. Replies
    3
    Views
    1,107

    From what I am told... No...it is Siemens...

    From what I am told...
    No...it is Siemens software that you can add
    a BACNET driver to integrate to a BACNET system.
  35. Thread: Trane pcm

    by d_d_c_jci
    Replies
    6
    Views
    1,025

    Can you email that to me too: Try: ...

    Can you email that to me too:

    Try: oshimi16@hotmail.com

    Thank you in advance.
  36. Thread: Trane UPCM

    by d_d_c_jci
    Replies
    18
    Views
    2,337

    KNOBBER: Did you try to email me that UPCM...

    KNOBBER:

    Did you try to email me that UPCM edit manual yet?

    Try:

    oshimi16@hotmail.com


    Thank you in advance.
  37. Replies
    9
    Views
    1,551

    Thanks for the reponses. I will put the schedule...

    Thanks for the reponses.
    I will put the schedule for 5 mins
    in unoccupied mode.
    I also seen some of these boxes stuck in recalibrate mode
    during the 5-5 schedule. I had to change it back to...
  38. Thread: Firewall

    by d_d_c_jci
    Replies
    1
    Views
    707

    Firewall

    I have separate bldgs with Metasys PMI.
    The customer wants to put it on their T1
    but wants us to supply a firewall.
    I am currently looking at Cisco.
    What firewall do you recommend?
  39. Replies
    9
    Views
    1,551

    Is the recalibrate for the damper only? Should...

    Is the recalibrate for the damper only?
    Should it be setup for after hrs or during the occupied time?
  40. Replies
    9
    Views
    1,551

    VAV recalibrate

    Does anyone know what the Trane Summit is
    doing when there is a 5am to 5 pm schedule
    for VAV recalibrate. How do I verify that all boxes
    are included?
  41. Replies
    2
    Views
    1,063

    Tnaks but I already figured it out. It was my...

    Tnaks but I already figured it out.
    It was my USB bluetooth adapter.
    I had to buy a D-LINK adapter instead
    of the one that I had.
  42. Thread: Trane UPCM

    by d_d_c_jci
    Replies
    18
    Views
    2,337

    SORRY...... I don't know why it didn't go...

    SORRY......

    I don't know why it didn't go through but

    try:

    oshimi16@hotmail.com
  43. Thread: Trane UPCM

    by d_d_c_jci
    Replies
    18
    Views
    2,337

    I have no manual but if you have one can you...

    I have no manual but if you have one can you email it to me?

    oshimi16@yahoo.com
  44. Thread: Trane UPCM

    by d_d_c_jci
    Replies
    18
    Views
    2,337

    I went in and I copied someone elses password to...

    I went in and I copied someone elses password to create my own but
    didn't pay attention to what I hads access to.
    I will check again.
  45. Thread: Trane UPCM

    by d_d_c_jci
    Replies
    18
    Views
    2,337

    It is controlling an multizone airhandler. I'm...

    It is controlling an multizone airhandler.
    I'm am trying to find zone setpts and cold deck setpts
  46. Thread: Trane UPCM

    by d_d_c_jci
    Replies
    18
    Views
    2,337

    Trane is coming in a month

    Trane is coming in a month
  47. Thread: Trane UPCM

    by d_d_c_jci
    Replies
    18
    Views
    2,337

    There are no as-builts and the customer has to...

    There are no as-builts and the customer has to wait a month
    for Trane service. There is a link on Summit to PCM edit but
    not UPCM edit.
    I did what mallron said and found only the OA min pos setpt...
  48. Thread: Trane UPCM

    by d_d_c_jci
    Replies
    18
    Views
    2,337

    They are at version 16. All i'm trying to do is...

    They are at version 16.
    All i'm trying to do is add the point to the graphic
    so the customer can adjust.
  49. Thread: Trane Bcu

    by d_d_c_jci
    Replies
    12
    Views
    1,592

    I will check the wiring harnesses and wires...

    I will check the wiring harnesses and wires tomorrow... Thanks.
  50. Thread: Trane UPCM

    by d_d_c_jci
    Replies
    18
    Views
    2,337

    By the way I'm trying to find the controlling...

    By the way I'm trying to find the controlling setpt...
    room setpt or discharge setpt.
Results 1 to 50 of 184
Page 1 of 4 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event