Search:

Type: Posts; User: learning08

Search: Search took 0.00 seconds.

  1. Replies
    37
    Views
    11,428

    sent to your email already.

    sent to your email already.
  2. Replies
    37
    Views
    11,428

    USB tech key which opens all versions but has 8...

    USB tech key which opens all versions but has 8 hr time limit each time
  3. Replies
    37
    Views
    11,428

    Anyone has spare alerton tech key to sell?

    Anyone has spare alerton tech key to sell?
  4. Replies
    4
    Views
    335

    Hi maxburn, thanks for your reply. I initially...

    Hi maxburn,

    thanks for your reply. I initially tried using my own gateway and didn't have any luck.

    I then tried using modscan which gave me exception 4.

    can you clarify what you mean by...
  5. Replies
    4
    Views
    335

    modbus Exception 4

    hi,

    would appreciate if anyone can give me some clues as to what are the possible reasons for modbus exception 4 error.

    is wiring termination one of them? if not, what other things could it be?...
  6. Replies
    2
    Views
    350

    modbus 485 connection

    hello everyone,
    i need some help. i have a modbus device which has 3 terminals which i need to connect to my controller (master) which has only 2 terminals. Both are using modbus 485 but the slave...
  7. Replies
    15
    Views
    875

    Thanks! Got it.

    Thanks! Got it.
  8. Replies
    15
    Views
    875

    Thanks Kontrolphreak. Just to clarify, does this...

    Thanks Kontrolphreak. Just to clarify, does this mean I would need to ensure that my global is within the mac address of 1 to 10 or does it mean as long as I have other field controllers within mac...
  9. Replies
    15
    Views
    875

    Hi Amigo, Thanks for the reply. I have seen...

    Hi Amigo,

    Thanks for the reply. I have seen that advise elsewhere but since there is a limitation on my new field device to be installed, I am trying to figure out if there'll be problems arising...
  10. Replies
    15
    Views
    875

    Thanks again Reaper. I tend to think the same way...

    Thanks again Reaper. I tend to think the same way ie as long as the global has its max master set to max mac addresses on the net, it should be ok as all communications is via the global.
  11. Replies
    15
    Views
    875

    Thanks Reaper! My global max masters as well...

    Thanks Reaper!

    My global max masters as well as my other existing field devices has the max masters by defaults at 127. However this new device which I am installing (not global controller but a...
  12. Replies
    15
    Views
    875

    Thanks Reaper! My global max masters as well...

    Thanks Reaper!

    My global max masters as well as my other existing field devices has the max masters by defaults at 127. However this new device which I am installing (not global controller but a...
  13. Replies
    15
    Views
    875

    BACnet setting - Max Masters

    Hi!

    Need some help. I have a new Bacnet device which I need to add to existing BACnet/MSTP network. If my current used up MAC address is example 1,2,3,4 .... up to 100 (with Max masters setting...
  14. Replies
    178
    Views
    27,070

    hi! i understand that only the new bcm's suport...

    hi!
    i understand that only the new bcm's suport nat. for vlx which doesn't support nat and is behind a nat firewall and no server locally, can i still do remote login? if so, can you give a rough...
  15. Replies
    178
    Views
    27,070

    nor does the bbmd need info about the pc i...

    nor does the bbmd need info about the pc i guess...
  16. Replies
    178
    Views
    27,070

    sorry, bbmd doesn't hv info about the pc ...

    sorry, bbmd doesn't hv info about the pc ...
  17. Replies
    178
    Views
    27,070

    can I have multi server (server and not clients!)...

    can I have multi server (server and not clients!) in:
    1. same network
    2. across networks

    asking this coz i want to login to a alerton system running ebt2.1. hopefully i can log in as server....