  1. Replies
    5
    Views
    177

    www.lynxspring.com

    www.lynxspring.com
  2. You need the 9 pin adapter part #35914262 and...

    You need the 9 pin adapter part #35914262 and cable part #35914260

    Google the manual because dip switch 2 number 7 like on the cover could be set to 1200, flipping it the opposite way should put...
  3. Replies
    2
    Views
    88

    Your baud rate should be 1200

    Your baud rate should be 1200
  4. Thread: Carrier RTUs

    by joey791
    Replies
    5
    Views
    114

    How old are the RTUs? You can get Bacnet/Modbus...

    How old are the RTUs? You can get Bacnet/Modbus translators and Lonworks translators if you don't want to do CCN.
  5. Replies
    1
    Views
    110

    Trane makes a retrofit...

    Trane makes a retrofit http://www.trane.com/commercial/north-america/us/en/products-systems/equipment/terminal-devices/variable-air-volume/round-in-round-out-.html
  6. Or dirty filters, I've seen whole buildings with...

    Or dirty filters, I've seen whole buildings with no heat because no one noticed they had filters in the vav and the same ones from the original install was still in them.
  7. Replies
    30
    Views
    925

    Put your location in your profile, some of these...

    Put your location in your profile, some of these guys may be local to you
  8. Are the filters clean on the vav boxes?

    Are the filters clean on the vav boxes?
  9. Replies
    8
    Views
    326

    Unfortunately can't write it out that good but if...

    Unfortunately can't write it out that good but if I was there and had some tubing and fittings.....................
  10. Replies
    22
    Views
    1,373

    Yeah all mine are red but they are labeled. Red...

    Yeah all mine are red but they are labeled. Red 16 gauge 24VAC hot on outputs, White 16 gauge 24VAC common on outputs, shielded cable for inputs and analog outs

    My labels on my analog outputs,...
  11. Replies
    22
    Views
    1,373

    Unfortunately my middle conduit is crooked,...

    Unfortunately my middle conduit is crooked, retrofit I did about 4 years ago.

    527091527101
  12. Replies
    22
    Views
    1,373

    Around here in Louisiana thats par for the...

    Around here in Louisiana thats par for the course, if it doesn't put another dime in someones pocket its not worth doing.
  13. Replies
    8
    Views
    696

    Saw this today and just had to share

    526351
  14. Replies
    3
    Views
    224

    That was being said since AHR 2013, also a rumor...

    That was being said since AHR 2013, also a rumor that you will no longer use Lon routers but a "dumbed down jace" in their place.
  15. Replies
    3
    Views
    224

    Its the gateway and should have Lonmaker and the...

    Its the gateway and should have Lonmaker and the programming on it.
  16. Replies
    3
    Views
    172

    What command letter only seems d for display...

    What command letter only seems d for display works

    Sent from my SAMSUNG-SM-G900A using Tapatalk
  17. Replies
    3
    Views
    172

    Siemens Panel Time Change

    Can someone give me some guidance on how to change the date and time in a Siemens panel? I've searched through Google and pulled manuals and can't seem to find it anywheres. Any help is appreciated.
  18. Thread: CSE-5111

    by joey791
    Replies
    5
    Views
    188

    Thats a Titus Analog Control Board ...

    Thats a Titus Analog Control Board

    http://www.titus-hvac.com/Products/Terminal%20Units/TA1#

    Be prepared, the old style with the integrated actuator and electronic 3 wire airflow pickup was...
  19. Replies
    3
    Views
    279

    Don't ever use the door as your points list, of...

    Don't ever use the door as your points list, of all the DXs I have worked on maybe 3 had the correct points on the door.
  20. Replies
    6
    Views
    327

    They are made more for pressure monitoring but...

    They are made more for pressure monitoring but have you called Setra? Used these before and they were pretty nice(pressure in vivariums)
    ...
  21. Thread: A/C renew

    by joey791
    Replies
    17
    Views
    826

    If the crap that got peddled actually did...

    If the crap that got peddled actually did anything for system performance and was good for the system, wouldn't you think that manufacturers would put that product in their system before it leaves...
  22. Replies
    12
    Views
    2,065

    Looking for this and BCS can't find my copy

    Looking for this and BCS can't find my copy
  23. Replies
    5
    Views
    316

    40VA transformer isn't going to carry 30 actuators

    40VA transformer isn't going to carry 30 actuators
  24. Good DDC techs can make that too, no knock on the...

    Good DDC techs can make that too, no knock on the refer guys, but I would stay doing controls.
  25. http://www.free-mcquay.com/bizlit/DocumentStorage/...

    http://www.free-mcquay.com/bizlit/DocumentStorage/Controls/InstallationandOperationManuals/IM564.PDF
    Check page 7
    ...
  26. Sorry worms, didn't know if that would help any.

    Sorry worms, didn't know if that would help any.
  27. Replies
    2
    Views
    179

    What model boiler and line of Raypaks are you...

    What model boiler and line of Raypaks are you using
  28. If you google mcquay Loop Water Controller Manual...

    If you google mcquay Loop Water Controller Manual it brings up all kinds of manuals that may help, the MIG manual, the LWC manual, a Siemens manual, etc.
  29. Thread: Trane VSEE vav

    by joey791
    Replies
    5
    Views
    305

    Made to mount up directly to the box ...

    Made to mount up directly to the box
    ...
  30. Replies
    1
    Views
    362

    still looking

    still looking
  31. No one in India but here is their international...

    No one in India but here is their international distributors

    http://workaci.com/distributors/international/list
  32. Contact ACI, 1-888-Workaci, talk to Travis...

    Contact ACI, 1-888-Workaci, talk to Travis Phillips and the part you need is a A/RH2-R2
  33. Replies
    7
    Views
    286

    one each, shoot me an email(its in my profile)...

    one each, shoot me an email(its in my profile) rather not post my zip code
  34. Replies
    7
    Views
    286

    Don't worry about it, I want them, send me your...

    Don't worry about it, I want them, send me your paypal addy so I can send you the money.
  35. Replies
    7
    Views
    286

    workbooks or textbooks? If its the textbooks I...

    workbooks or textbooks? If its the textbooks I want the Metasys ones.
  36. Replies
    13
    Views
    335

    I don't think you can, I didn't really get a...

    I don't think you can, I didn't really get a chance to get into R2 that much.
  37. Replies
    13
    Views
    335

    Checked the lessons learned site and nothing...

    Checked the lessons learned site and nothing really helpful to this situation there, would be nice to have the error log from the UNC
  38. Replies
    13
    Views
    335

    No sorry, not with the more info you are given. ...

    No sorry, not with the more info you are given.

    Are all the 1000s bacnet/ip, how many of them do you have, how many controllers are connected to each one mstp, etc. Any info along these lines on...
  39. Replies
    13
    Views
    335

    Have you changed the battery?

    Have you changed the battery?
  40. Replies
    5
    Views
    446

    Wouldn't happen to be in Louisiana? I know the...

    Wouldn't happen to be in Louisiana? I know the New Orleans branch has a few openings.
  41. What the hell is icecold?

    What the hell is icecold?
  42. Are the supply and exhaust fans working properly?

    Are the supply and exhaust fans working properly?
  43. Replies
    4
    Views
    365

    Well 2S-means secured 2U-means UL listed...

    Well

    2S-means secured
    2U-means UL listed smoke control equipment
    2E-means Europe
  44. Replies
    27
    Views
    1,188

    No after, love coming across these. Other tech-I...

    No after, love coming across these. Other tech-I don't understand I have a full sightglass but its not cooling, me-what are your pressures, other tech-haven't checked them but the sightglass is full...
  45. Replies
    13
    Views
    829

    Great, you can look here for someone that is in...

    Great, you can look here for someone that is in your area Charles.

    http://hvac-talk.com/vbb/forumdisplay.php?1012-AOP-HTalk-Contractor-Map
  46. Replies
    27
    Views
    1,188

    Thats not usually the issue when you do this, the...

    Thats not usually the issue when you do this, the material in the drier being blown through the system is.
  47. Replies
    13
    Views
    829

    Well this is what your doing wrong, best price...

    Well this is what your doing wrong, best price doesn't mean best value or best install. Put your location on your profile so a reputable member can contact you of course if your just looking for...
  48. Replies
    10
    Views
    579

    The proper way to do it is to pull the plug, if...

    The proper way to do it is to pull the plug, if you have any doubt, pull the plugs on some motors that haven't been done. I can tell you it completely opened my eyes.
  49. Replies
    6
    Views
    396

    Actually some specs we dealt with actually said...

    Actually some specs we dealt with actually said the job wasn't complete until you gave owner's training and we had to videotape it for proof of completion.
  50. Replies
    27
    Views
    1,188

    I'll go against the grain on this one, outside...

    I'll go against the grain on this one, outside the condenser. We don't have many issues with rust through here and then if it is outside the condenser(not in it), the system can be pumped down. If...