10-02-2011, 07:46 PM
Thread: -3 deg f Superheat
by local 832s- Replies
- 83
- Views
- 3,471
Direct liquid injection system:whistle:
Direct liquid injection system:whistle:
-
10-02-2011, 07:45 PM
Thread: -3 deg f Superheat
by local 832s- Replies
- 83
- Views
- 3,471
I've seen plenty of neg superheat on low temp...
I've seen plenty of neg superheat on low temp racks during flood back situations!
-
10-01-2011, 08:01 AM
- Replies
- 21
- Views
- 1,640
I would check LLSV. Start compressor (only the...
I would check LLSV. Start compressor (only the troubled one) let it run for awhile. Then raise set point and watch it. See if it pumps down correctly.
-
10-01-2011, 07:55 AM
Thread: Management Salary?
by local 832s- Replies
- 12
- Views
- 1,890
Where are you located? Looks like maybe jersey?...
Where are you located? Looks like maybe jersey? Too little unless it's managing a few techs then you could moonlight to make up the difference:grin2:
-
10-01-2011, 07:54 AM
Thread: Management Salary?
by local 832s- Replies
- 12
- Views
- 1,890
Where are you located? Looks like maybe jersey?...
Where are you located? Looks like maybe jersey? Too little unless it's managing a few techs then you could moonlight to make up the difference
-
08-27-2011, 11:06 AM
- Replies
- 23
- Views
- 1,750
sporland rcw-42....look it up
sporland rcw-42....look it up
-
08-27-2011, 10:57 AM
- Replies
- 23
- Views
- 1,750
Ok....If I have a contaminated system IE(.Burn...
Ok....If I have a contaminated system IE(.Burn out), I use the appropriate suction line filter drier and replace in a few days. They make them specifically for high moisture and acid exposed systems....
-
08-27-2011, 10:50 AM
Thread: blast chillers
by local 832s- Replies
- 23
- Views
- 1,478
Still a bit low on charge I would say. Subcooling?
Still a bit low on charge I would say. Subcooling?
-
08-25-2011, 05:58 AM
- Replies
- 23
- Views
- 1,750
I hate to answer a question with a question but...
I hate to answer a question with a question but why do they make both suction AND liquid line filter driers?
-
08-23-2011, 11:14 AM
- Replies
- 23
- Views
- 1,750
NO!!!
NO!!!
-
07-09-2011, 06:26 AM
Thread: EPR adjustment to lower evap pressure
by local 832s- Replies
- 3
- Views
- 600
All the ones Ive worked on have been ccw to lower...
All the ones Ive worked on have been ccw to lower psi. That said, it's not a set in stone rule just my experience.
-
03-06-2011, 01:21 PM
Thread: need help on evacuation equiptment
by local 832s- Replies
- 14
- Views
- 1,475
3/8" makes a difference for larger systems. A 2...
3/8" makes a difference for larger systems. A 2 or 3lb system 1/4" is fine. I work mostly on 50-1000lb systems so 3/8" is in my hands often. Core removal is also a must on recovery of large...
-
03-05-2011, 08:51 AM
Thread: pumping out a condenser
by local 832s- Replies
- 35
- Views
- 2,069
Ok I give up. Just do it anyway you would like....
Ok I give up. Just do it anyway you would like. Not mad but don't know how else to explain pumping down a system into the RECEIVER not CONDENSER.
-
03-05-2011, 07:38 AM
Thread: pumping out a condenser
by local 832s- Replies
- 35
- Views
- 2,069
If you close the outlet of the receiver it all...
If you close the outlet of the receiver it all has to at some point go through the condenser.
Think about the cycle it'll work perfectly. I can pump a 400# rack down 99% in just a few min then... -
03-04-2011, 03:59 PM
Thread: pumping out a condenser
by local 832s- Replies
- 35
- Views
- 2,069
As I said, I meant no offense. Just don't wanna...
As I said, I meant no offense. Just don't wanna step by step a consumer.
I still stand by my method of pumping it down to the receiver. Simply close the outlet to the receiver and let it pump... -
03-04-2011, 11:29 AM
Thread: pumping out a condenser
by local 832s- Replies
- 35
- Views
- 2,069
I see no reason why the refrigerant can't be...
I see no reason why the refrigerant can't be condensed. The OP simply asked the quickest way to pump out a condenser.
Now if he asked the quickest way to pump out a condenser without fans..... -
03-04-2011, 07:12 AM
Thread: pumping out a condenser
by local 832s- Replies
- 35
- Views
- 2,069
^^^^ No offense but you don't have pro status...
^^^^ No offense but you don't have pro status thus I'm not walking you through step by step.
I can assure you though that IF you get pro status come back and your questions can be answered. -
03-03-2011, 09:53 PM
Thread: pumping out a condenser
by local 832s- Replies
- 35
- Views
- 2,069
use compressor to pump into receiver. No faster...
use compressor to pump into receiver. No faster way imho.
-
02-28-2011, 07:20 AM
Thread: 2 inches of ice in Walk-in freezer
by local 832s- Replies
- 39
- Views
- 2,565
Most likely infiltration
Most likely infiltration
-
02-27-2011, 08:19 PM
Thread: Walk-In Freezer
by local 832s- Replies
- 26
- Views
- 2,128
Totally normal..... on a -20 rack:whistle: ...
Totally normal..... on a -20 rack:whistle:
http://i1094.photobucket.com/albums/i453/2002vinny/frostly.jpg -
12-06-2010, 09:02 AM
- Replies
- 7
- Views
- 835
^^^^ agree^^^^^ I replace mine with o rings from...
^^^^ agree^^^^^ I replace mine with o rings from lowes or HD and works fine.
On another note, I think using analog is good to start off. New techs need to think about whats going on with the... -
12-05-2010, 07:47 PM
Thread: Paragon timer ?
by local 832s- Replies
- 19
- Views
- 1,631
Installed a few and no complaints so far.
Installed a few and no complaints so far.
-
12-05-2010, 04:14 PM
Thread: Paragon timer ?
by local 832s- Replies
- 19
- Views
- 1,631
paragon has a new digital timer that replaces all...
paragon has a new digital timer that replaces all the 8000 series so no need to carry multiple timers for paragon replacement. Also had a memory program that has 10 hrs of life after power outages....
-
11-15-2010, 04:28 PM
Thread: median hourly wage?
by local 832s- Replies
- 24
- Views
- 3,191
80k????? Thats a bad bad year:pileon:
80k????? Thats a bad bad year:pileon:
-
07-22-2010, 11:31 AM
- Replies
- 18
- Views
- 2,175
Just a guess.... 17-20/hr
Just a guess.... 17-20/hr