    You can use your original BacNet commissioning...

    You can use your original BacNet commissioning kit. There is Bacnet Router selection in PCT when you are loading or commissioning a controller.
  2. Thread: honeywell xl15b

    by foyler
    Replies
    6
    Views
    926

    The XL15B is commissioned through LonSpec, but...

    The XL15B is commissioned through LonSpec, but needs to have a network connection to do it as opposed to a direct lon connection. When you connect select SLTA, Wan, XL15B, put in the XL15B user name...
  3. Replies
    9
    Views
    1,012

    W7750C is one of the selections in E-Vision...

    W7750C is one of the selections in E-Vision version 1.2 and Configuration Files version 1.3. Maybe you have an older version?
  4. Replies
    5
    Views
    882

    It's in the E-Vision folder.

    It's in the E-Vision folder.
  5. Replies
    5
    Views
    882

    n-state point can be created in switching logic....

    n-state point can be created in switching logic. Software Points, Pseudo Digital, give it a name, select sub-type n-state.

    The cfg file is for metric vs imperial units and is located in the...
  6. Replies
    32
    Views
    2,997

    In a nutshell it's the balancing tool for...

    In a nutshell it's the balancing tool for Honeywell XL10 and Spyder vav controllers. Allows you to set multiple boxes to max or min airflow setpoints or max/min valve positions. Allows adjustments to...
  7. Replies
    32
    Views
    2,997

    Valves too! Download from Honeywell Here...

    Valves too!
    Download from Honeywell Here
  8. Replies
    4
    Views
    903

    I had something similar happen when the point in...

    I had something similar happen when the point in AX was mapped as a NumericWritable point instead of plain Numeric.

    Even though there was no override, the point in the Vma1620 wouldn't work...
  9. Thread: FX Alarming

    by foyler
    Replies
    2
    Views
    393

    Right-click on foreground color and choose...

    Right-click on foreground color and choose animate. Select if true and if false colors. You could also animate the blink property so that stays solid when normal and blinks when in alarm. That should...
  10. Replies
    5
    Views
    1,132

    I would check the connections between the...

    I would check the connections between the thermostat and the controller. Maybe a cut/disconnected/loose wire.

    If you really want to see what's going on you could use RapidBalance to view the VAV...
  11. Replies
    12
    Views
    2,250

    If you're just balancing you can use...

    If you're just balancing you can use RapidBalance. Download here:
    http://customer.honeywell.com/Business/Cultures/en-US/Products/Applications+and+Downloads/RapidBalance%e2%84%a2+-+Version+4.0.htm
  12. Replies
    7
    Views
    1,201

    You can get them here:...

    You can get them here:
    http://pub.controls.johnsoncontrols.com/publish/b2b_aa/us/eng/abcs_exchange/facility_explorer/tecnical_support/facility_explorer_applications.html
  13. Replies
    26
    Views
    4,330

    Thanks, Dave. Appreciate the information. We...

    Thanks, Dave. Appreciate the information.

    We were hoping for an internet solution, but I guess not yet... but it will be nice not to have to bounce back and forth between the router and FX20/60...
  14. Replies
    26
    Views
    4,330

    Can someone provide more info on using the...

    Can someone provide more info on using the FX20/60 as the BACnet router for JCI CommPro BACnet through an internet connection?

    Is there a particular port that needs to be opened to the FX20/60 or...
  15. Replies
    4
    Views
    1,090

    If you have an existing boolean schedule that you...

    If you have an existing boolean schedule that you want to use to inhibit the alarm during unoccupied -

    open the schedule, go to property sheet, right click the schedule name, link mark.
    Open...
  16. Replies
    32
    Views
    2,834

    Chris, You have mail.

    Chris,

    You have mail.
  17. Thread: AX and N2 Comms

    by foyler
    Replies
    3
    Views
    630

    If it's an older FX60 you may need to install the...

    If it's an older FX60 you may need to install the 2.0.3 update. jcin2.jar and jcifxdriver.jar are both updated. You need Workbench to install. Available here:...
  18. Replies
    4
    Views
    872

    Did you select unit of measure - us when...

    Did you select unit of measure - us when generating the prn file? If so add a display to the FX07 and add System Point, Unit of Measure, US to one of the pages.
  19. Thread: FX20 Web Server

    by foyler
    Replies
    4
    Views
    553

    You'll need port forwarding on ports 1911 and...

    You'll need port forwarding on ports 1911 and 3011 to access remotely.
  20. Replies
    13
    Views
    2,069

    Anyone can access them from JCI:...

    Anyone can access them from JCI:
    http://pub.controls.johnsoncontrols.com/publish/b2b_aa/us/eng/abcs_exchange/facility_explorer/tecnical_support/facility_explorer_applications.html
  21. Replies
    4
    Views
    515

    I think you're going to need Workbench to get...

    I think you're going to need Workbench to get into the platform to change it back.
  22. Replies
    8
    Views
    591

    If you do an RMA the replacement part is an...

    If you do an RMA the replacement part is an LP-KIT400B-700. That's just the circuit board. JCI says it has more memory than the original.
  23. Replies
    8
    Views
    591

    I'm not sure what causes it, but I have one just...

    I'm not sure what causes it, but I have one just like it. I'm wondering if it has something to do with upgrading it to 2.0? Did you upgrade yours or was it 3.3.22 to start with?
  24. Replies
    8
    Views
    591

    This is from the JCI solutions database: Per...

    This is from the JCI solutions database:

    Per Brian Johnson (Tridium), Mar 07/08: "If you look [at the following URL using a browser connection] http://<jaceip>:3011/qnx/ndioc!status and see...
  25. Replies
    4
    Views
    542

    Open the bound label for editing, right click on...

    Open the bound label for editing, right click on the word foreground and select animate. Converter type should be "I Boolean To Simple". Choose colors for true and false values. You can do the same...
Results 1 to 25 of 71
Page 1 of 3 1 2 3
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event