  1. Replies
    6
    Views
    344

    Well it's actually http://swftec.com/GPG03.htm

    Well it's actually http://swftec.com/GPG03.htm
  2. Replies
    6
    Views
    344

    Found the program http://swftec.com/index.htm ...

    Found the program
    http://swftec.com/index.htm

    This is a custom program that allows you to work outside of the "Box"
  3. Replies
    6
    Views
    344

    JCI HVACpro text program

    Hello,
    I'm trying to find the text program someone wrote to access the johnson controls VAV \ UNT controllers.

    Can anyone remember the link in this site or the name

    Thanks
  4. Hope this worked

    Here's the doc
  5. Found the document and yup - 2 is the deivce ID....

    Found the document and yup - 2 is the deivce ID. Once I figure out how to attach an document, I'll post it which will help in the integration. what I was thinking of at the end of the string is @15
  6. Who did the intergation? bacnet://2/AO:2172 are...

    Who did the intergation? bacnet://2/AO:2172 are you reading this from the AO string in Webcontrol?? Change the //2 to //16 in Webcontrol and see if you can override at 15.
    In Webcontrol you can add...
  7. Replies
    21
    Views
    1,393

    Within the Metasys world they use a different...

    Within the Metasys world they use a different method to communicate to each other. That's why you have all the BACnet ID @ 500 which is the default. BUT if you were to BACnet these into another...
  8. Replies
    4
    Views
    484

    What version

    What version
  9. Open up the FEC (MSTP) bus in the focus window....

    Open up the FEC (MSTP) bus in the focus window. Click on the engineering tab and do I scan. Does it find anything?

    Then click on the Diagnostic tab and click on the Advance bullet. Do a screen...
  10. Replies
    2
    Views
    317

    There are two types of N30s: the original N30-0...

    There are two types of N30s: the original N30-0 and the new N30-1. Choose the one in Project Builder that matches your hardware.

    The primary difference between the two models is the amount of...
  11. Replies
    20
    Views
    1,701

    Not a problem - BACnet and BBMD are one of the...

    Not a problem - BACnet and BBMD are one of the biggest misunderstanding people have. I've been luckly to work on several BACnet/OPC projects writing code etc to gain this understanding (lots of head...
  12. Replies
    20
    Views
    1,701

    - Depending on how to you ask for information....

    - Depending on how to you ask for information. For example, the software program by Chipkin "BACnet Explorer" uses Device ID and 47808. This brings back all the BACnet/IP devices on the system.

    -...
  13. Replies
    20
    Views
    1,701

    Once I figure out how to attach my screen shot -...

    Once I figure out how to attach my screen shot - it shows the NCE BACnet site as False and using Chipman BACnet/IP Explorer finding the NCE with objects on the network - so the site does not need to...
  14. Replies
    51
    Views
    3,436

    Can't post pictures - what's up THanks

    Can't post pictures - what's up

    THanks
  15. Replies
    6
    Views
    390

    We used around 15 of the S2N2E device over our...

    We used around 15 of the S2N2E device over our network. Sam stands behind his product and worked with us.

    The only draw back is that you can't download the N2 devices over the S2N2E - unless he...
  16. Replies
    20
    Views
    1,701

    Straight from JCI engineer: The NxE is...

    Straight from JCI engineer:

    The NxE is discoverable by default, nothing special is required to enable it to be discoverable.

    So here is some information on what to look for \ change

    The...
  17. Replies
    20
    Views
    1,701

    fdefoy, Did you try the about. As stated, the...

    fdefoy,

    Did you try the about. As stated, the NAE is the BACnet/IP device. As of now, you have the ADS as the site manager in the NAE. If you disconnect the NAE from the ADS, and put the NAE as...
  18. Replies
    1
    Views
    243

    BACnet

    The NAE is BACnet/IP and not BACnet over Ethernet. So verify that KMC can communicate using BACnet/IP.

    Then in the NAE you will need to setup the BACnet intergration object which will allow the...
  19. Replies
    20
    Views
    1,701

    have you tried to talk with all the NAE's. By...

    have you tried to talk with all the NAE's. By default, the NAE is setup for BACnet/IP. There is nothing to setup except the deivce ID which is 500 by default.

    The ADS Server has nothing to do with...
  20. Replies
    20
    Views
    1,701

    In the NAE under the focus tab, you will have the...

    In the NAE under the focus tab, you will have the object ifentifiter which is 500 in your case. Also you have the 1001 network address.
    If you open the tree, do you see a BACnet object? should will...
  21. Replies
    20
    Views
    1,701

    NAE55

    Most likely all the NAE's have the device ID as 500. This is the default and 99.99 % of the time never gets changed.

    Second you communicate to the NAE not the ADS. Go into a NAE and from the Tree...
  22. Replies
    9
    Views
    407

    Hello, Installed after 2005, not sure on the...

    Hello,
    Installed after 2005, not sure on the extra year. When it's running, I do see some water coming from the evap coil. The furance is rated for 1200 CFM and based on Mr.Bill, 1 ton = 400 CFM I...
  23. Replies
    9
    Views
    407

    Hello, Checked the duct work all seems good. Not...

    Hello,
    Checked the duct work all seems good. Not sure what is manaul J & D are?? You can tell when the furance is on, as it's moving a lot of air though the duct work. I'll have to check on the...
  24. Replies
    9
    Views
    407

    Tempstar Furance and AC question

    Hello,
    We just purchased a home with a 2005 tempstar furance (T9MPV075F12B1) and AC unit (TXA224AKA2). From what I gather, this furance has multiple taps for the motor. The factory setting is high,...
  25. Replies
    1
    Views
    204

    stat or furance control board??

    Hello,

    Figured this would be a good place to start. I have a furance which runs all the time and does not shutdown. In cooling, the fan starts and then the AC. And it doesn't shutdown. Only when I...
  26. Replies
    10
    Views
    572

    N2 Bus

    Under the NAE, open the N2 bus in the main window. Click on the engineering tab. It might come up with a auto-discovery window say Yes. If it doesn't click on the Relean button. This will scan your...
  27. Paladin

    I guest it's as easy as pie!! Our electrians give us a Paladin tool which worked? And go figure it's a Time Design Reflectometer.
  28. Diasychain

    Good day to all.

    Thanks for the insight. To add onto this, we would disconnect every daisychain connections to the controllers. Then we need to get the distance between each controller and then...
  29. Tool to read the distance of a 2,3 or 4 wire cable.

    Hello,

    I'm looking for a device which willl allow us to read a 2, 3 or 4 wire daisychain communication run.

    We tried a $18K Fluke network tool and didn't like the daisychain. What would be...
  30. Are you using the fieldserver tools on your PC??...

    Are you using the fieldserver tools on your PC?? if not get these from the web and run the Remote User Interface program.

    Are you sure the IP in the fieldserver is correct? what is the sub and...
  31. N2

    Power cycle the working DX9100 and see what version it is. Then power cycle the effected one and check this version.

    Do you have any other TC9102 that are on the network that is not causing this...
  32. Replies
    0
    Views
    197

    JCI LCT Logic - how to create a COS

    Hello,

    In the NAE LCT logic program, I need to active a horn from an input to output. Pretty simple, but I would like to use a COS, so once the latch is reset it won't be triggered again - unless...
  33. Replies
    3
    Views
    251

    Hello, The hotdog looking object has nothing...

    Hello,

    The hotdog looking object has nothing in it for the on/off times. I'm not at the site, but remember that beside the BV object for the default it has a statement saying that if BACnet...
  34. Replies
    3
    Views
    251

    ALC Priority Array

    Hello,

    We have logic program which causes a priority level of 6 (min on/off) if we change the default from Off to on. We don't have anything writing to this at that level and figure it's something...
  35. Replies
    6
    Views
    524

    YUP all 8 PLC's are used up - using all the PLC...

    YUP all 8 PLC's are used up - using all the PLC blocks for a operator lite panel and horns.

    The other option I have is to wrtie logic in the NAE to do the latching, and control the outputs...
  36. Replies
    6
    Views
    524

    Is this the part I don't fully understand. In the...

    Is this the part I don't fully understand. In the PLC, I used a SET command. So when the input goes on it latches this on. The only way to reset this is with the RST command. I don't have room in the...
  37. Replies
    6
    Views
    524

    DX9100 PLC Reset - Expert help needed!

    Hello,

    I have a JCI program with PLC logic that is using a SET command to keep on a lite. That's fine, but I need to Reset this from a NAE and not from the RST in the PLC.

    Is their any JCI...
  38. Replies
    17
    Views
    1,190

    Thanks - didn't know that.

    Thanks - didn't know that.
  39. Replies
    17
    Views
    1,190

    Touch Screen

    Hello,

    So time ago, someone had put on this forum a spead sheet on testing several different touch screen panels. I search but couldn't located it.

    Does anyone know were this baby is.

    Thanks
  40. Replies
    4
    Views
    363

    We didn't send any reload command. Once we put a...

    We didn't send any reload command. Once we put a new field controller on the Acrnet, it wants to download all the field controllers for ALL branches (routers).

    We checked teh BBMD and they are...
  41. Replies
    4
    Views
    363

    ALC WebCrtl V6.0 download Question

    Hello,

    We have several routers with around 30 field controllers connected. When we add in another field controller to one router, it tells us to download all the controllers? What I find odd, why...
  42. Replies
    2
    Views
    421

    Hello, The problem turned out to be with IT...

    Hello,

    The problem turned out to be with IT security. Once they opened the ports, everthing is fine.
  43. Replies
    8
    Views
    1,005

    Hello, We are changing our BMS from Honeywell...

    Hello,

    We are changing our BMS from Honeywell to ABB. The output module that we use from the ABB is only 24VDC. Since most items are 3 wire (share common) we would create a problem with using...
  44. BAPI

    Hello,
    In our OR this is what we did - replaced the JCI stat with a BAPI that output 0-10 for the temperature range and 0-10 for the adjust.
    Then reprogram the controller to accept the 0-10, and...
  45. Replies
    8
    Views
    1,005

    Yes - the damper actuator is for a VAV app. I did...

    Yes - the damper actuator is for a VAV app. I did find Belimo NMBx24-SR- which might work.

    As for the heating valve, the one we are replacing is the Honeywell M6410A to a version that is 24VDC...
  46. Replies
    8
    Views
    1,005

    24VDC powered Damper and Valve Actuator

    Hello,

    I looked around the web and can't really find what I need, looking for suggestions. We are looking for a valve actuator which is powered by 24VDC and outputs 0\2-10VDC. The only one we can...
  47. Replies
    4
    Views
    490

    Hello, I've done several jobs with fieldserver...

    Hello,

    I've done several jobs with fieldserver (JCI N2\MSTP to OPC, modbus, MSTP) and the only thing which I have to input, is the work that is requried on the configuration file.

    They always...
  48. Replies
    2
    Views
    421

    JCI N30 Site Manager HELP

    Hello,

    I installed System Tools 5.4 on a vitual XP Machine for the N30. The install when fine, no errors but when I try to run the Site Manager to connect to the N30 via ethernet, it gives me the...
  49. Mult Digital Inputs to one Analog Output

    Hello,

    Does anyone know of a device which will accept mult digital inputs and convert this to a single analog outout. So for example if we have 4 digital inputs, the analog output would be...
  50. Replies
    5
    Views
    378

    MAMAC System

    We need to send out the alarm message via ethernet. The sensaphone only uses the phone line.

    Thanks