Search:

Type: Posts; User: gastech

Search: Search took 0.00 seconds.

  1. Replies
    34
    Views
    12,215

    Some replies never cease to amaze me. Almost as...

    Some replies never cease to amaze me. Almost as bad as the argument that filling up your car in the morning with gas will give you better yields as opposed to filling it up in the evening. Just run...
  2. Replies
    14
    Views
    1,522

    Pull out the gas, blow out the coils and replace...

    Pull out the gas, blow out the coils and replace tube and drier. Put a fork in it and walk away.
  3. Replies
    11
    Views
    2,616

    The company I work for does refrigeration and...

    The company I work for does refrigeration and cooking equipment. We do all the HVAC work for the customers that have contracts with us. So we cover the whole restaurant. We do most of the major...
  4. Replies
    8
    Views
    1,448

    Use a hairdryer here and there. Heat up the...

    Use a hairdryer here and there. Heat up the material to make it fit.
  5. Replies
    18
    Views
    1,907

    How do I get a job in Guam? Or the USVI for that...

    How do I get a job in Guam? Or the USVI for that matter. I'm tired of the cold.
  6. Replies
    7
    Views
    856

    I have seen some very nasty stuff growing on...

    I have seen some very nasty stuff growing on evaps in some very well known chains. It's enough to make you blow chunks. Toilet water is cleaner. The soda valves are just as bad. This is a whole new...
  7. Replies
    3
    Views
    1,911

    Built for Burger King. Worked on a few. Call Duke...

    Built for Burger King. Worked on a few. Call Duke 1-800-735-3853
  8. Replies
    32
    Views
    6,444

    No mention of M# for starters. Master Jet or High...

    No mention of M# for starters. Master Jet or High Efficiency. Also too much finger pointing and this and that. Replace the valve. Verify manifold pressure. Or call in a service company and watch and...
  9. Thread: tiny bubbles?

    by gastech
    Replies
    20
    Views
    1,438

    A full glass don't mean squat . A hot box w/clean...

    A full glass don't mean squat . A hot box w/clean coils and properly operating valve and vapor pump will show bubbles. Let temp come down to near SP. If a LAC valve is involved then you will need to...
  10. Thread: what if?

    by gastech
    Replies
    4
    Views
    1,166

    Why do you want to increase the amp draw? What is...

    Why do you want to increase the amp draw? What is the SFA rating ? If there is one. For all you know the motor size and pulley sizes may be wrong. Voltage plays a big part as well. Wheel size...
  11. Replies
    16
    Views
    3,404

    Never heard that one. But I do know that Copeland...

    Never heard that one. But I do know that Copeland warns against fan cyclers on units w/semi hermetics unless the suction line is wraped around the body.
  12. Replies
    26
    Views
    2,549

    Manitowoc and Hoshi are by far the leaders. I...

    Manitowoc and Hoshi are by far the leaders. I can't stomach the rest. Just replaced the original board on a '95 B model the other day. That unit still had all it's original parts on it and it still...
  13. Replies
    13
    Views
    1,433

    De-ice it and clean it and replace the float...

    De-ice it and clean it and replace the float switch. Chk operation of the bin stat by putting pump into wash. Put in freeze mode and chk temps by touchy feely. Let 'em fall and chk bin stat in a...
  14. Replies
    5
    Views
    678

    T'stat is going. Change it.

    T'stat is going. Change it.
  15. Replies
    14
    Views
    4,080

    These units will pull into a vac. when cold then...

    These units will pull into a vac. when cold then drop off to near zero when at temp. Depending on your altitude the temp may never hit 212F. The vac. pump is there to remove air which is a...
  16. Thread: tech pay

    by gastech
    Replies
    7
    Views
    1,017

    The Co. I work for pays hourly and o/t is time...

    The Co. I work for pays hourly and o/t is time and a half. We have 10 techs w/2 on call once every 5 weeks. We get paid admin. pay when on call. That's for answering the phone and dealing with the...
  17. Replies
    14
    Views
    1,672

    Got a call on a Norlake WIC running warm. Climbed...

    Got a call on a Norlake WIC running warm. Climbed up on top and found several hard starts laying around. Comp. hot as hell. Tecunseh. Label said it was a 208/230 single phase. Ohmed out windings and...
  18. Replies
    15
    Views
    2,937

    A full sight glass don't mean squat. If you're...

    A full sight glass don't mean squat. If you're charging to a full glass then you're doing it wrong. Some techs swear by mounting driers vertical to maintain a head of liquid. Wrong again. Proper...
  19. Replies
    14
    Views
    2,956

    One other thing. If press. are ok in a harvest,...

    One other thing. If press. are ok in a harvest, then your chg. is ok. If they are off in a freeze, then the txv is bad. Normal sheet will be just a hair thinner at the top. Get a book on that model...
  20. Replies
    14
    Views
    2,956

    What size machine? If its small and you put hoses...

    What size machine? If its small and you put hoses on it you just lost some of the charge and created a new problem. Possible that the tubing is separating from the backside. Evaps have a 5 yr....
  21. Thread: headmasters

    by gastech
    Replies
    13
    Views
    1,807

    A clear sight glass don't mean nothing. At low...

    A clear sight glass don't mean nothing. At low ambients alot of the refrigerant is sitting in the reciever. I've worked on some Hussmans that required 4 lbs. more after a clear sight glass. Simulate...
  22. Replies
    22
    Views
    1,578

    Chk for tube separation on back side of plate....

    Chk for tube separation on back side of plate. Thicken up the slab. Replace machine.
  23. Thread: Kairak

    by gastech
    Replies
    17
    Views
    2,573

    Do you love cleaning cond. coils on kairaks? Our...

    Do you love cleaning cond. coils on kairaks? Our techs have rotated some of the cond. units on non warranty units and added a coil of tubing to help w/ moving them should the comp. die. All the...
  24. Thread: Who buys what?

    by gastech
    Replies
    9
    Views
    1,205

    Non union here. Small co. w/9 trucks. The techs...

    Non union here. Small co. w/9 trucks. The techs buy all of our own tools. Am fortunate to work for a man who pays very well and gives out bonuses accordingly. W/that bonus I buy what I want. I work...
  25. Replies
    11
    Views
    2,502

    Danfoss.....good valves. proper charge....even...

    Danfoss.....good valves. proper charge....even better.Good way to tell if you got a bad valve or are low on gas.........put unit into a harvest.if press. are good..you gat a bad valve. If press. are...
  26. Replies
    22
    Views
    2,951

    get the head at about 275.back at about 50-60..a...

    get the head at about 275.back at about 50-60..a full sight glass don't mean squat.
  27. Replies
    8
    Views
    1,083

    Replace 'em. It's quicker and is more income. The...

    Replace 'em. It's quicker and is more income. The customer should keep the machine clean. If you do clean 'em , dry it completely before re-installing it.
  28. Replies
    17
    Views
    2,989

    replace the sensor and rod. The rod gets worn out...

    replace the sensor and rod. The rod gets worn out from riding up and down.
  29. Thread: Norlake Box

    by gastech
    Replies
    4
    Views
    743

    Tecumseh. I know it was a 3 phase because all 3...

    Tecumseh. I know it was a 3 phase because all 3 windings ohmed out the same. We even cut it open and it had an internal o/l.
  30. Thread: Norlake Box

    by gastech
    Replies
    4
    Views
    743

    got a call on a w/i cooler stopped cooling. Found...

    got a call on a w/i cooler stopped cooling. Found a 3 phase comp. wired up w/start components. Been running like that for little over a year on 208 single phase. I found the relay stuck open. Ohmed...
  31. Replies
    4
    Views
    954

    Manitowocs are my fav. The J and Q models are...

    Manitowocs are my fav. The J and Q models are easiest to diagnose. The S models seem to be ok. The flakers have not presented any probs yet. Hoshi's are great too. The freeze ups are a pain though....
  32. Thread: McCall leaker

    by gastech
    Replies
    3
    Views
    794

    just worked on a 3 door McCall freezer today...

    just worked on a 3 door McCall freezer today that's only 6 months old. Out of gas. Found leak on disch. line where hpco connects. Bad weld job from the factory. 404 leakers can be a pain. On small...
  33. Thread: manitowoc

    by gastech
    Replies
    7
    Views
    834

    remove the cap from the standpipe and with the...

    remove the cap from the standpipe and with the unit in the ice making mode, adj. float so the water level is 1/4 inch below top of stand pipe. Unit won't siphon if water level is off. Replace cap...
  34. Replies
    10
    Views
    1,067

    Bet you had a error code #2. Harvest time...

    Bet you had a error code #2. Harvest time exceeded 3.5 min.3x. Unplug ice thicness probe from board. If light goes out, board probably ok. If light stays on, chuck the board. If unit is in a manual...
  35. Replies
    17
    Views
    1,768

    Your gonna need a water agitator, a 3000 btu unit...

    Your gonna need a water agitator, a 3000 btu unit for 5 gal. tank, and go w/a txv. Or go buy a used Haskris or Mltiplex unit.