Waterford was purchased by Fireplace Products...
Waterford was purchased by Fireplace Products international (better known as Regency fireplaces). Regency stopped making them but they would be the best people to talk to regarding the parts.
-
02-11-2012, 03:39 PM
Thread: GDI30 issues
by fire-parts- Replies
- 3
- Views
- 921
Sounds like the unit might be turning on and off...
Sounds like the unit might be turning on and off quickly causing gas to build up and boom. Check loose wiring or bad switch
-
02-11-2012, 03:33 PM
Thread: How does this switch ever work?
by fire-parts- Replies
- 2
- Views
- 1,169
That is a mercury switch. They are not field...
That is a mercury switch. They are not field serviceable and no longer available.
-
11-19-2011, 12:01 PM
- Replies
- 6
- Views
- 815
Agree with talktowags. The only way to get the...
Agree with talktowags.
The only way to get the heat into the whole house is using the furnace duct system. Just make sure not to de-pressurize the room with the stove in it too much that it smokes... -
11-14-2011, 11:18 PM
- Replies
- 10
- Views
- 1,282
I agree with Hearthman, I would check the glass...
I agree with Hearthman, I would check the glass seal as pretty much every old red silicone gasket glass is shot by this time. If it is still the red silicone gasket I would recommend changing it even...
-
11-14-2011, 10:35 PM
Thread: Gas Line
by fire-parts- Replies
- 4
- Views
- 536
Your pipe sizing also depends on gas pressure. If...
Your pipe sizing also depends on gas pressure. If its a 1/2 pound (low pressure) or a 2lb (high pressure gas meter). All appliances run on low pressure so if your house is high pressure you will see...
-
11-03-2011, 06:50 PM
- Replies
- 3
- Views
- 728
There are no efficient see-through inserts. The...
There are no efficient see-through inserts. The only way to get efficiency is to put in a normal single sided insert on one side.
-
10-17-2011, 03:55 PM
Thread: Dovre DV450S need burner
by fire-parts- Replies
- 3
- Views
- 669
Things like burners are made by the manufacturer...
Things like burners are made by the manufacturer and the only place to get it is from the manufacturer.
Online you can get replacement parts like valves, switches, ect. because the manufacturer (in... -
09-29-2011, 10:41 PM
Thread: direct vent termination kit questions
by fire-parts- Replies
- 6
- Views
- 813
Technically speaking, you should only use a vent...
Technically speaking, you should only use a vent kit that is tested and approved for the exact fireplace model you are installing.
-
09-28-2011, 11:29 PM
Thread: direct vent termination kit questions
by fire-parts- Replies
- 6
- Views
- 813
If you do put two lengths together, make sure to...
If you do put two lengths together, make sure to seal the joints with a high temperature sealant like this- ...
-
09-24-2011, 09:17 PM
Thread: (Heat N Glo) No High Flame
by fire-parts- Replies
- 5
- Views
- 1,192
Either the solenoid on the valve isn't working,...
Either the solenoid on the valve isn't working, or it is working and you just can't see the difference between hi and low. Sometimes, on some units, it can be hard to see the flame difference.
You... -
09-23-2011, 02:07 PM
Thread: Help Identify a Pilot assembly
by fire-parts- Replies
- 5
- Views
- 824
Here is a better picture of that SIT pilot. It...
Here is a better picture of that SIT pilot. It looks like it will replace the PSE pilot exactly
-
09-22-2011, 11:15 PM
Thread: Help Identify a Pilot assembly
by fire-parts- Replies
- 5
- Views
- 824
This SIT pilot assembly might work...
This SIT pilot assembly might work
http://www.fire-parts.com/replacement-parts/pilot-assemblies/sit-side-mount-pilot-assembly.html