11-18-2004, 04:48 PM
Thread: Could I have done more?
by joe kool- Replies
- 24
- Views
- 2,201
There are two things you can be sure of in a...
There are two things you can be sure of in a kitchen environment. Dirty, greasy, air cooled condensers with poor heat exchange properties and pourous, pitted evap coils caused by acids in many types...
-
10-14-2004, 11:47 AM
Thread: chain comp.failure..
by joe kool- Replies
- 10
- Views
- 741
the head pressure should never "skyrocket" , this...
the head pressure should never "skyrocket" , this is probably caused by non - condensibles in the system. Remove refrigerant and pull a deep vacuum on system (below 500 microns and holds). This may...
-
10-08-2004, 05:45 PM
Thread: Beverage Glass Reach-In
by joe kool- Replies
- 6
- Views
- 748
Those settings seem fine. The old control may...
Those settings seem fine. The old control may have been operating at the correct C-I and C-O. What a lp control indicates visually, and what it actually operates at, often conflict with each other.
-
10-06-2004, 03:46 PM
Thread: Reach In pressures
by joe kool- Replies
- 16
- Views
- 1,457
the "throw stones" comment was not directed...
the "throw stones" comment was not directed towards you , dave. Sorry for the misunderstanding. thanks for following up on the solution, selfemployed.
-
10-05-2004, 06:37 AM
Thread: Reach In pressures
by joe kool- Replies
- 16
- Views
- 1,457
sorry for the sarcasm dave...but if you live in a...
sorry for the sarcasm dave...but if you live in a glass house - you don't throw stones !
-
10-04-2004, 09:52 PM
Thread: Reach In pressures
by joe kool- Replies
- 16
- Views
- 1,457
Hmmm... mechanically remove refrigerant, remove 6...
Hmmm... mechanically remove refrigerant, remove 6 inches of cap tube, re-solder tube, pull deep vacuum on system, add nitrogen to verify leak-free and add refrigerant to system just to still have...
-
10-02-2004, 11:03 PM
Thread: Reach In pressures
by joe kool- Replies
- 16
- Views
- 1,457
Remove refrigerant, replace filter drier and cap...
Remove refrigerant, replace filter drier and cap tube (properly sized) Pull vacuum on system and slowly charge to about 13-17 PSI on suction. R134 systems are notorius for having restricted cap tubes...
-
09-18-2004, 06:34 PM
Thread: Line size charts. Suct/Liq/Disc online?
by joe kool- Replies
- 7
- Views
- 767
Tecumseh puts out a free Service Handbook in PDF...
Tecumseh puts out a free Service Handbook in PDF format, that has tons of great technical and reference material (including line sizing guides) It is a large file @ 3.7 MB , but well worth the wait....