    IF you can raise it without kinking the lines and...

    IF you can raise it without kinking the lines and the electric is flexible enough, then go for it, but a 11/2' sounds like a lot.
    The quote you got is probably about right. There is alot more to it...
  2. Replies
    12
    Views
    1,887

    yes, the time clock is OK. It seemed like the ice...

    yes, the time clock is OK. It seemed like the ice I melted off was on the back outside of the evap coil, not any in the coil itself.
  3. Replies
    12
    Views
    1,887

    I have a walk in freezeer which is maintaining 0...

    I have a walk in freezeer which is maintaining 0 degrees, but they called and said there was a 3' icicle. I get there and noticed this icicle hanging off the bottom of the suction line trap where the...
  4. Replies
    1
    Views
    805

    Just want to say "thank you" to all our veterans...

    Just want to say "thank you" to all our veterans out there. You are appreciated.
  5. Replies
    5
    Views
    1,507

    Remember class, flame impingement means...

    Remember class, flame impingement means incomplete combustion which gives us what? right.....CO. Not unnormal(is that a word?) for you to get soem around a stove.
  6. Replies
    23
    Views
    5,401

    OMG! tell me these are digitally altered...lol

    OMG! tell me these are digitally altered...lol
  7. Thread: Neat job

    by theharleyman
    Replies
    18
    Views
    4,427

    I wonder how well the a/c works???

    I wonder how well the a/c works???
  8. Replies
    21
    Views
    3,650

    Re: Just for funnies sometime,

    WHAT???? I was born at night , but not last night. Sorry, I can't buy this 95%RH stuff, no way.
  9. Replies
    21
    Views
    3,650

    This a lenghty subject because there is no ONE...

    This a lenghty subject because there is no ONE right answer because there are too many variables. Around here most people shoot for 35%. Some can do it, some can't without getting condensation. Thats...
  10. Replies
    6
    Views
    1,553

    I'm not a big fan of unvented heateres either in...

    I'm not a big fan of unvented heateres either in most cases. If I did have one, I would definately have a CO detector though. Remember that when this thing is new and clean and burning good (if the...