  1. Possible.

    Possible.
  2. Fan Set: ON = Fan runs continuously Auto...

    Fan Set:

    ON = Fan runs continuously
    Auto = Fan runs when there is a call for cool or heat
    Cir = Fan runs for y amount of minutes IF no cool or NO heat call in x amount of minutes. And x...
  3. Replies
    1
    Views
    125

    Carrier CEPL130202-02

    Can anyone can help me how to access this controller?

    Software?
    Cross-over cable?

    Help

    Thanks
  4. Have you aver done a load calculation of the...

    Have you aver done a load calculation of the building ????? If not, then let's stop assuming anything.
  5. Code E311: Warning Only. Furnace blower in...

    Code E311: Warning Only. Furnace blower in cutback mode due
    to restricted airflow. Reduce firing rate every 60
    seconds to match available CFM. Check filter and
    duct system. To clear, replace...
  6. Tashier, Please take all pictures and document...

    Tashier,

    Please take all pictures and document them. You need to present them to Lennox so they can fix your issues, WHICH IS AIR FLOW. Each region will have a sale and technical reps. They will...
  7. Tashier, Please take all pictures and document...

    Tashier,

    Please take all pictures and document them. You need to present them to Lennox so they can fix your issues, WHICH IS AIR FLOW. Each region will have a sale and technical reps. They will...
  8. Replies
    2
    Views
    212

    Ask your tech to look into the configuration to...

    Ask your tech to look into the configuration to enable the SSR and to enable it for how many hours look-ahead.
  9. With above information given by you, I don't...

    With above information given by you, I don't think air leak in the system is your problem. Becuse if you have air leaks bad enough, you ain't gonna have any of those good information mentioned above...
  10. Replies
    8
    Views
    352

    WIFI vision Pro has exact same feature as the old...

    WIFI vision Pro has exact same feature as the old one you have. ONE EXCEPTION: WIFI does not have humidity sensor.
  11. The problem that you have is typical for any...

    The problem that you have is typical for any heatpump system that is not properly configured with a proper thermostat. Here is what you have and it is a common vicious cycle of a typical heat pump.
    ...
  12. Replies
    5
    Views
    311

    Don't and DON'T Cause the old XC16 unit will...

    Don't and DON'T

    Cause the old XC16 unit will be wasted. And so will be the Harmony 3. Not including the labor cost you spent will for sure be 100% wasted.
  13. Replies
    9
    Views
    383

    Weight in

    Weight in
  14. This will disable the OD unit from running in...

    This will disable the OD unit from running in heat mode when OD temp is at certain temp. BUT

    Wonder how this will help the outdoor unit from going into defrost every 15 minutes.
  15. That's a lot of smoke comes out of his/her rear....

    That's a lot of smoke comes out of his/her rear.

    Find another company.
  16. Replies
    4
    Views
    302

    Can't tell you cause no DIY. BUT Google and...

    Can't tell you cause no DIY.

    BUT

    Google and you can find it. I did.
  17. Replies
    9
    Views
    485

    We installed many of this XC and XP25 series....

    We installed many of this XC and XP25 series. They are great unit.

    In my opinion, XC-25 series is best for zoning system AND I have not found one yet to beat it. But, I think XC-21 series is...
  18. Replies
    10
    Views
    588

    SOMETIMES, the bottom rows are for subcool...

    SOMETIMES, the bottom rows are for subcool circuit, which are not too hot and to dissipate the least of heat. Also, bottom rows get all the water, which is cold, dripping down from the top circuits....
  19. Replies
    1
    Views
    253

    I think the E model has springs. Piece of junk....

    I think the E model has springs. Piece of junk.
    It is possible the relief valve (notorious of failure). PITA to get to

    1 hr 45 minute per head. Hopefully gasket did not get caked in that head.
    ...
  20. Replies
    12
    Views
    625

    Care to elaborate the #1

    Care to elaborate the #1
  21. Replies
    12
    Views
    503

    Care to help us to help you with the M# and S#....

    Care to help us to help you with the M# and S#. Cuz last time I heard, york makes more than 1 variable peed furnace.

    And yes, I am being sarcastic. Sorry but true.
  22. Replies
    11
    Views
    406

    I LOVE GOOGLE. Hope everyone else loves it like...

    I LOVE GOOGLE. Hope everyone else loves it like you and I do. The answer is within those 6 letters.

    I even "google" for my spelling.

    :grin2:
  23. Replies
    5
    Views
    389

    This thermostat is for Heatpump. This thermostat...

    This thermostat is for Heatpump. This thermostat will energize Y (24 volts present) on both mode: Cool and Heat.
    That's why when this zone calls for heat, there is 24 volt present at the Y either...
  24. Replies
    5
    Views
    389

    On you thermosat 51M53, did your contractor set...

    On you thermosat 51M53, did your contractor set it to heatpump OR single stage heat/cool?

    To know that, you can push the SETTING button and see if you see "EMG HEAT".

    What I try to get at is...
  25. Replies
    10
    Views
    457

    Maybe he has 2 weeks in the bid. BUT he tells you...

    Maybe he has 2 weeks in the bid. BUT he tells you 2 days so you can pick up your feet.

    That's why he is the boss.