10-04-2012, 11:38 AM
Thread: Tridium AX BBMD
by stopher9- Replies
- 7
- Views
- 568
It will not let me add by left clicking. I am...
It will not let me add by left clicking. I am waiting for permission to cycle power because this unit is controlling a clean room. I hope it takes the configuration and up-dates the changes after the...
-
10-04-2012, 10:59 AM
Thread: Tridium AX BBMD
by stopher9- Replies
- 7
- Views
- 568
Does anyone know if I need to Re-Start the...
Does anyone know if I need to Re-Start the station after you make the station a BBMD to be able to modify the BDT?
-
10-03-2012, 08:54 PM
Thread: Tridium AX BBMD
by stopher9- Replies
- 7
- Views
- 568
Tridium AX BBMD
How do you add a BBMD to a Niagara panel. Do you add this under the Link tab?
-
10-03-2012, 02:09 PM
Thread: Cypress Envirosystems BBMD
by stopher9- Replies
- 0
- Views
- 170
Cypress Envirosystems BBMD
Does anyone out there know if Cypress Environsystems Green Box has a BBMD? The documentation say's its BBMD enabled but I do not know where to go to get this... Anyone out there deal with this...
-
08-18-2011, 11:54 AM
Thread: ASI Controller.... ASIC/2-8040
by stopher9- Replies
- 2
- Views
- 502
ASI Controller.... ASIC/2-8040
I wanted to know if this was a BaCnet device that I would be able to integrate into a siemens system via BaCnet?
-
05-11-2011, 05:28 PM
Thread: Johnson Controls N31
by stopher9- Replies
- 5
- Views
- 616
Thanks Bill. Is there a default log on that...
Thanks Bill. Is there a default log on that JCI uses to get into these controllers?
-
05-11-2011, 05:14 PM
Thread: Johnson Controls N31
by stopher9- Replies
- 5
- Views
- 616
What Baud Rate do you use for Hyperterminal.
What Baud Rate do you use for Hyperterminal.
-
05-11-2011, 03:39 PM
- Replies
- 4
- Views
- 625
View Post
ÄB.CTWR1.SS#2 Must have the same virtual address as the DI virtual address within the L2SL.
-
05-11-2011, 03:31 PM
Thread: Johnson Controls N31
by stopher9- Replies
- 5
- Views
- 616
Johnson Controls N31
I have a site that we have taken over that has a JCI N31. I have Project Builder abd Site Book.... How do I get into the N31 and upload into the project builder? What type of cables do I need?
-
09-07-2010, 08:00 PM
Thread: Trane Voyager Supply Air Reset
by stopher9- Replies
- 4
- Views
- 668
Trane Voyager Supply Air Reset
I have a Trane voyger unit, 25-50 ton unit that i'm trying to install a supply air reset from a siemens system. I was told all I need a reset board that has a 0-10 VDC input and a 0-1000 ohm output....
-
11-20-2008, 12:02 PM
Thread: Carrier Model # 48DK044
by stopher9- Replies
- 4
- Views
- 304
it has an extermal Reset board that connects to...
it has an extermal Reset board that connects to terminals 12 and 15...
-
11-20-2008, 12:01 PM
Thread: Carrier Model # 48DK044
by stopher9- Replies
- 4
- Views
- 304
it has an extermal Reset board that connects to...
it has an extermal Reset board that connects to terminals 12 and 15...
-
11-20-2008, 10:58 AM
Thread: Carrier Model # 48DK044
by stopher9- Replies
- 4
- Views
- 304
Carrier Model # 48DK044
I have a Box car Air Handler thats a Carrier Model # 48DK044 that has a Supply Air Reset board in it and im trying to find out if it can take a 0-10 VDC signal to it. Anyone??????
-
06-17-2008, 03:22 PM
Thread: Siemens controls - CIS
by stopher9- Replies
- 29
- Views
- 3,200
you will have to get your hands on wincis. that...
you will have to get your hands on wincis. that will take care of your problem
-
04-03-2008, 11:39 PM
Thread: How to Calculate BTU's on CHW System
by stopher9- Replies
- 18
- Views
- 32,556
How to Calculate BTU's on CHW System
Whats a good way to calculate BTU'S on a chilled water system.
-
03-11-2008, 07:52 PM
Thread: Control Panel Maintenance
by stopher9- Replies
- 19
- Views
- 1,128
I would run any kind of reports you could on your...
I would run any kind of reports you could on your DDC Panels through your work station to find any failed points and and Programming that could help save energy.
-
01-03-2008, 08:29 PM
Thread: Siemens Insight alarmable points trouble
by stopher9- Replies
- 12
- Views
- 917
Try uploading the panel
Try uploading the panel
-
11-14-2005, 02:33 PM
Thread: VAV Controllers
by stopher9- Replies
- 9
- Views
- 4,451
what exactly does DMS stand for im pretty new to...
what exactly does DMS stand for im pretty new to the controls industries and only know siemens software