  1. JACE 6 Low Disk Space, Where is all my disk space?

    Hi,

    I'm having trouble here and can't figure out what is causing my space to disappear. I've opended up the Resource Manager and I see a high network percentrage usage. Never seen that before.
    ...
  2. Replies
    7
    Views
    310

    Now I need to figure out the bit packs. need to...

    Now I need to figure out the bit packs. need to write to register 40039 BIT 1 to clear the accumulated kWH Data.
  3. Replies
    7
    Views
    310

    You are the man, thanks for all the help. got it...

    You are the man, thanks for all the help. got it figured out. I needed to move the Array that the data was read from the modbus meters, then move it to another array but during the move I have to...
  4. Replies
    7
    Views
    310

    Wow. I never knew there was a in depth menu. Ok I...

    Wow. I never knew there was a in depth menu. Ok I found it and seems like the modbus portion is whats reading the values wrong. Lon is spitting out what ever modbus is feeding it. Now I need to...
  5. Replies
    7
    Views
    310

    Wrapped in Code Tags.

    //================================================================================
    //
    // config.csv
    //
    // FST Customer...
  6. Replies
    7
    Views
    310

    My Attempt to configure it.

    //================================================================================
    //
    // config.csv
    //
    // FST Customer...
  7. Replies
    7
    Views
    310

    Fieldserver config.csv help

    Hi.

    I've got a fieldserver from SMC and I'm having trouble writing the config.csv. The fieldserver is a MODBUS RTU to LON. Trying to get the Square D Enercept Meters to map correctly to LON.
    ...
  8. Replies
    0
    Views
    172

    JCI LX-RTUL Configuration Wizard

    Hi,

    I've got my hands on 3 LX-RTUL controllers and I commissioned and discovered the points, over 300 or so, and I tried to configure them, inputs/outputs etc. NCI Enumarations and controller...
  9. Replies
    12
    Views
    990

    email in my profile, definitely interested. got...

    email in my profile, definitely interested. got ya covered for a beer.
  10. Replies
    14
    Views
    1,678

    That really sucks because JACE is a great...

    That really sucks because JACE is a great product, but the graphics just make it look bad. And to use distechs image library although look better than tridiums but require the module to be loaded and...
  11. Any update to this? Sent from my iPhone...

    Any update to this?


    Sent from my iPhone using Tapatalk
  12. Replies
    14
    Views
    1,678

    HVAC Graphics Library

    Hi,

    anyone have a decent graphics library for hvac controls? the PX files that come with the JACE are sub par.

    simple AHU's and duct work/sensors/ fans, etc.

    thank you.
  13. Replies
    9
    Views
    547

    As you and @kontrolphreak mentioned, all points...

    As you and @kontrolphreak mentioned, all points are exposed, the only issue is to configure the analog input, which I don't care at this point. I did connect the VLC to the mstp and discovered all...
  14. Replies
    9
    Views
    547

    @kontrolphreak thx for the info, makes lots of...

    @kontrolphreak thx for the info, makes lots of sense. These VLC's came from a job, customer didn't want them so I ended up with them. We cut over the building with ALC and used SE cards in combo with...
  15. Replies
    5
    Views
    468

    ^^^ Can you expand on that a little more? We are...

    ^^^ Can you expand on that a little more? We are stating to deal with JACE BACnet. I know in ALC they way foreign LGR's work.
  16. Replies
    9
    Views
    547

    Program Alerton VLC-16160

    This is to all Alerton guys, I've got a few VLC-16160 controllers, which talk BACnet, they used to control cooling towers but now I have ALC running the show now, but is there any way to get all...
  17. 3 Year Old Amana not cooling well but numbers are good.

    My accumulator was icing up because I had over charged it thinking it was under charged based on I had 0F subcooling, I charged it, my head pressure came up a bit and low pressure didn't do anything,...
  18. 3 Year Old Amana not cooling well but numbers are good.

    Yep, sound just like the issue I had at my house. A new good man beat pump, and had a bad Indoor txv, got that replaced under warranty and sucker now has 20-22F coil delta. Pressures seemed fine, I...
  19. Replies
    7
    Views
    556

    Yep, I got a goodman air handler and same here....

    Yep, I got a goodman air handler and same here. "B" is common. No C. A lot of the manufactures these days are doing away with O and B switching of the Reversing Valve. Instead you close R to W1 and...
  20. We use industrial spec'ed UPS' when we encounter...

    We use industrial spec'ed UPS' when we encounter a brown out, they are din rail mountable from SOLA. http://www.solahevidutysales.com/sdu_offline_din_rail_ups_series.htm

    We get the SDU850 UPS's,...
  21. BACnet Error 61456 WritePropMultiple no Attempt | W.C 6.0 | York RTU's

    We have 3 York RTU's, and from time to time we get a "61456 WritePropMultiple no Attempt" error on Occupied Enable point, and this error prevents the Unit from going into Occupied Mode, until I log...
  22. Replies
    32
    Views
    1,533

    BACnet is what we use, depending on the project...

    BACnet is what we use, depending on the project specs, but there have been projects where "LON" was a requirement.
  23. I had a friend of mine stop by and look at it, he...

    I had a friend of mine stop by and look at it, he connected his gauges, and we had no subcooling and high superheat, a different story in heating mode. 10F subcooling in heating mode, but none in...
  24. I was getting 64F discharge with a 72F return

    I was getting 64F discharge with a 72F return
  25. I did have gauges connected to it yesterday, it...

    I did have gauges connected to it yesterday, it was 70F outside when I had them connected and had 5f subcool and 72F superheat. Thats not a typo, 72F superheat. Something not right I know, but why...
  26. I mean bulb and everything else seems to be...

    I mean bulb and everything else seems to be secure, nothing damaged, I opened the TXV and it helped but but not a significant amount, got it to 8F deltaT, but not where a coil should be, that sucker...
  27. Heat Pump works great in Heat Mode, but not in cooling mode

    Hi, Summer is creeping up quick and yesterday was the first day it got above 75F in my area, I decided to turn on the heat pump in cool mode for the first time and not much action, compressor runs...
  28. JACE AX American Auto Matrix PUP Driver, GX Setpoints Write Error.

    Hello,

    We have a site that has 30+ controllers on a AAM PUP network, I got the PUP driver and documentation and set it up per the doc from niagara. I discovered all of my devices, and removed the...
  29. Replies
    64
    Views
    13,573

    I know that this is an old thread, but anyone...

    I know that this is an old thread, but anyone have the SOLO/MC and GX manuals? Cant find them any where on the web.
  30. Replies
    6
    Views
    405

    Thnx again, tested the modules and got the...

    Thnx again, tested the modules and got the database started on my laptop.
  31. Replies
    6
    Views
    405

    You are the man, I will try them tonight. ...

    You are the man, I will try them tonight.

    There's one weird module Im looking to find also linkster.jar by radware.
  32. Replies
    6
    Views
    405

    3.7

    3.7
  33. Replies
    6
    Views
    405

    Missing JAR modiles Niagara-AX

    Hello,

    We have a JCI JACE that failed, and we want to replace it with a Distech COntrols JACE, but I need the following modules to restore a failed JACE.

    jciParser.jar
    jciLXMain.jar...
  34. York YPAL ECO2 Proper SAT Control HELP.

    Hi,

    Has anyone bumped into this issue? We have 6 100ton York ECO2 AHU's that have been configured for VAV operation. What are the points I need to write to get it to control to SAT STPT....
  35. Replies
    18
    Views
    1,132

    Thx, couldn't find that particular doc, worked...

    Thx, couldn't find that particular doc, worked just as described. Appreciate it.
  36. Replies
    2
    Views
    326

    06A Certification Exam

    Hi,

    Got my NEC 2014 code book and ready to study. I don't assume the entire book will be on the test, but which sections are? Do you have a 2014 NEC study guide? I reside in Washington.
  37. Replies
    18
    Views
    1,132

    I tried and wrote to nviDACLSP at 65F and...

    I tried and wrote to nviDACLSP at 65F and nviDAHTSP 60F in the above example. i also tried setting them 10F apart, and not taking my setpoint, at certain times of the day, the setpoint will fall back...
  38. Replies
    3
    Views
    445

    Sunbelt Controls is another distech dealer.

    Sunbelt Controls is another distech dealer.
  39. Replies
    18
    Views
    1,132

    In the above example. i'm writing to nviSetpoint...

    In the above example. i'm writing to nviSetpoint of 65F, and nvoDischAirTemp is at 54F with 100% open econo. I tried modified occupied cooling/heating Cp points as well as nvis. unit not responding.
  40. Replies
    18
    Views
    1,132

    Yes, it is LON. thx for the assurance. I peeled...

    Yes, it is LON. thx for the assurance. I peeled another sticker of another AHU and it said echelon. I discovered and added the points. Only issue is I can't get the discharge air reset to work, other...
  41. Replies
    18
    Views
    1,132

    The board has the following part #: MQ-COM1203-0...

    The board has the following part #:
    MQ-COM1203-0

    I Can't find anything on this number.
  42. Replies
    18
    Views
    1,132

    That would simplify things, but no it's not LON,...

    That would simplify things, but no it's not LON, Plug has 3 terminal prongs, LON has 2, in any case, it's not LON because I peeled the white stickers on another AHU, and no mention of echelon
  43. Replies
    18
    Views
    1,132

    Well, the comm connects directly to a siemens NET...

    Well, the comm connects directly to a siemens NET port, no OPM panel.
  44. Replies
    27
    Views
    3,751

    The amount of F bombs, and S phrases were flying...

    The amount of F bombs, and S phrases were flying around, just made that place interesting to work. Roofers cursed like sailors. Some of the words exchanged, I have never heard of.

    Don, nice to see...
  45. Replies
    27
    Views
    3,751

    HAHA, nice, I was doing the hvac controls. I...

    HAHA, nice, I was doing the hvac controls. I thought those air handlers looked familiar.
  46. Replies
    6
    Views
    964

    WebCTRL has that built in, its a licensing thing...

    WebCTRL has that built in, its a licensing thing that gets added as a feature. Regular Enterprise license won't give you the superset features.
  47. Replies
    18
    Views
    1,132

    What protocol is this McQuay card using?

    Hi,

    I can't find any information on this comm card, hoping someone here can help. We're ripping out a siemens apogee 600 system, with a tridium front end.

    There are (3) 25-50 ton air...
  48. Thread: Apple watch

    by access_max
    Replies
    1,512
    Views
    53,884

    My trash can has an apple logo.

    My trash can has an apple logo.
  49. Thread: Apple watch

    by access_max
    Replies
    1,512
    Views
    53,884

    Ummmm. Ok. Lol. Apple watch is...

    Ummmm. Ok.






    Lol.

    Apple watch is over rated. I have a android wear watch that my wife got me for Christmas and love it.
  50. Replies
    12
    Views
    2,117

    Well that was for resi applications. Guess what...

    Well that was for resi applications. Guess what you're looking for is a full fledged econo control which I haven't seen either.
Results 1 to 50 of 84
Page 1 of 2 1 2

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Comfortech 365