    Is it set up as CV or VAV? It makes a difference.

    Is it set up as CV or VAV? It makes a difference.
  2. Replies
    1
    Views
    155

    VERIABLE??????????????????????????????????????...

    VERIABLE?????????????????????????????????????? What?????? spell check....... Your question makes no sense.
  3. Replies
    7
    Views
    215

    What is the issue?What brand unit?

    What is the issue?What brand unit?
  4. Replies
    7
    Views
    264

    reversing valve could be the problem but,...

    reversing valve could be the problem but, probably the compressor
  5. You tell the customer the the situation. Give...

    You tell the customer the the situation. Give them the option. You have contacted the dealer with no luck so far. I guarantee anything from BAC is usually twice as much money as anything you can get...
  6. Replies
    14
    Views
    766

    Check out this site for Trane info ...

    Check out this site for Trane info http://hvac.amickracing.com/RTU%20Training/Trane%20RTU%20info/
  7. I agree. Take it to your belimo dealer and toss...

    I agree. Take it to your belimo dealer and toss it on the counter. They will fix you up with linkage ,switches etc.
  8. Replies
    18
    Views
    766

    Dupont M099. You loose capacity. If the unit is...

    Dupont M099. You loose capacity. If the unit is undersized,dont use it. Us on exv,txv system. Replace any rubber o rings.
  9. Replies
    52
    Views
    2,828

    I just attended a Dupont refrigerant seminar. You...

    I just attended a Dupont refrigerant seminar. You can not mix. You can top off M099,a certain percent. I can't remember what percent (m099) off the top of my head.
  10. Thread: megged out

    by OhioTech
    Replies
    9
    Views
    602

    Meg IOL?

    Meg +250 good. Meg will show moisture of system and integrity of motor. If moisture on compressor body at terminals meg can read bad. IOL- amps? volts? load? head pressure? Connections?Contactor?
  11. Replies
    8
    Views
    721

    http://www.gordonpiattparts.com/manuals.htm ...

    http://www.gordonpiattparts.com/manuals.htm Manuals on line CiCi boiler..Gordon Piatt parts rep. John Zink bought Gordon Piatt
  12. Varitrane VAV fan ON and OFF- Mechanic with control question

    Varitrane VAV box. Heating fan off and on. Electric heat air flow switch was not making. Replaced filter.Pulled and cleaned blower. Heat works now when fan is running, But, fan starts and stops...
  13. Anyone plugged a tube on a fire tube boiler

    I have a fire tube boiler with one tube leaking. Boiler inspector noticed.The boilers are over 30 yrs old and are going to be replaced next year.I have a concern with plugging. If water enters the...
  14. Replies
    13
    Views
    1,342

    DONE!!!!!!!!!.Froze my A________ off! -3 deg 20...

    DONE!!!!!!!!!.Froze my A________ off! -3 deg 20 ft in air. LIVIN THE DREAM!Turbo torch to cut channels and holes in ice because pan was overflowing with ice up into the coil. Moved hose around...
  15. Replies
    13
    Views
    1,342

    Big Block of Ice

    Looking for ideas to thaw ice and replace a defective drain pan heater. Coil 20 ft in air. Pan a solid block of ice about 10ft long x 1ftwide x 6in deep . 0deg in room/warehouse. I need to get old...
  16. Replies
    42
    Views
    1,809

    Thanks for the info EngineerDave

    Thanks for the info EngineerDave
  17. Replies
    42
    Views
    1,809

    Thanks Eng Dave for info

    It looks as though the float on the seperator is hanging up and not allowing the oil to go to the oil receiver. Quoted customer new float assembly,henry oil level control for compressors and oil...
  18. Thread: P-66 or motor

    by OhioTech
    Replies
    7
    Views
    584

    All electric aside...make sure you are using a...

    All electric aside...make sure you are using a ball bearing motor. A sleave bearing will fail.
  19. Replies
    42
    Views
    1,809

    Central Ohio

    Central Ohio
  20. Replies
    42
    Views
    1,809

    I would say the suction line is 100-125ft...

    I would say the suction line is 100-125ft insulated untill it gets to the accumalator. Accumalator is a ball of ice.The compressor that has failed is thr first one after the accumalator. I will check...
  21. Replies
    42
    Views
    1,809

    OK then 20-25 deg superheat at compressor. I am...

    OK then 20-25 deg superheat at compressor. I am confused at the 6 deg at the evaps than was recommended and then 20-25 at the compressor. I guess maybe I should check the total tonnage of the...
  22. Replies
    42
    Views
    1,809

    I am getting replies from all of you so fast I am...

    I am getting replies from all of you so fast I am falling behind on your replies. I noticed someone said 6 degrees of superheat on the evaps.
  23. Replies
    42
    Views
    1,809

    No less than 20 degrees superheat? So like 10-15...

    No less than 20 degrees superheat? So like 10-15 Just want to make sure on the same page
  24. Replies
    42
    Views
    1,809

    The condensers looked clean. It is mounted right...

    The condensers looked clean. It is mounted right above the "shack" the compressors are in. Some genius mounted them there so its like working on an airplane with the props running. I did notice that...
  25. Replies
    42
    Views
    1,809

    The cannister I am talking about is on the side...

    The cannister I am talking about is on the side of each compressor. It has a sight glass and an adjustment to control the oil level. It mounts on the compressor where there is normally a sight glass....