05-15-2013, 06:02 AM
Thread: York ECO2 (YPAL)
by OhioTech- Replies
- 3
- Views
- 127
Is it set up as CV or VAV? It makes a difference.
Is it set up as CV or VAV? It makes a difference.
-
05-02-2013, 07:47 PM
Thread: veriable blower
by OhioTech- Replies
- 1
- Views
- 155
VERIABLE??????????????????????????????????????...
VERIABLE?????????????????????????????????????? What?????? spell check....... Your question makes no sense.
-
05-02-2013, 07:38 PM
Thread: WSHP TXV issues
by OhioTech- Replies
- 7
- Views
- 215
What is the issue?What brand unit?
What is the issue?What brand unit?
-
04-20-2013, 12:41 PM
Thread: addison watersource heatpump problems
by OhioTech- Replies
- 7
- Views
- 264
reversing valve could be the problem but,...
reversing valve could be the problem but, probably the compressor
-
04-06-2013, 11:47 AM
- Replies
- 9
- Views
- 305
You tell the customer the the situation. Give...
You tell the customer the the situation. Give them the option. You have contacted the dealer with no luck so far. I guarantee anything from BAC is usually twice as much money as anything you can get...
-
04-06-2013, 10:10 AM
Thread: Trane economizer troubleshooting
by OhioTech- Replies
- 14
- Views
- 766
Check out this site for Trane info ...
Check out this site for Trane info http://hvac.amickracing.com/RTU%20Training/Trane%20RTU%20info/
-
04-06-2013, 10:04 AM
- Replies
- 9
- Views
- 305
I agree. Take it to your belimo dealer and toss...
I agree. Take it to your belimo dealer and toss it on the counter. They will fix you up with linkage ,switches etc.
-
03-17-2013, 02:30 PM
Thread: R22 Replacement
by OhioTech- Replies
- 18
- Views
- 766
Dupont M099. You loose capacity. If the unit is...
Dupont M099. You loose capacity. If the unit is undersized,dont use it. Us on exv,txv system. Replace any rubber o rings.
-
03-17-2013, 02:26 PM
Thread: Topping off with R22 alternative....
by OhioTech- Replies
- 52
- Views
- 2,828
I just attended a Dupont refrigerant seminar. You...
I just attended a Dupont refrigerant seminar. You can not mix. You can top off M099,a certain percent. I can't remember what percent (m099) off the top of my head.
-
01-29-2013, 07:49 PM
Thread: megged out
by OhioTech- Replies
- 9
- Views
- 602
Meg IOL?
Meg +250 good. Meg will show moisture of system and integrity of motor. If moisture on compressor body at terminals meg can read bad. IOL- amps? volts? load? head pressure? Connections?Contactor?
-
10-27-2012, 12:26 PM
Thread: Gordon Piatt burners
by OhioTech- Replies
- 8
- Views
- 721
http://www.gordonpiattparts.com/manuals.htm ...
http://www.gordonpiattparts.com/manuals.htm Manuals on line CiCi boiler..Gordon Piatt parts rep. John Zink bought Gordon Piatt
-
10-12-2012, 06:26 PM
- Replies
- 4
- Views
- 501
Varitrane VAV fan ON and OFF- Mechanic with control question
Varitrane VAV box. Heating fan off and on. Electric heat air flow switch was not making. Replaced filter.Pulled and cleaned blower. Heat works now when fan is running, But, fan starts and stops...
-
09-09-2012, 05:57 PM
- Replies
- 5
- Views
- 666
Anyone plugged a tube on a fire tube boiler
I have a fire tube boiler with one tube leaking. Boiler inspector noticed.The boilers are over 30 yrs old and are going to be replaced next year.I have a concern with plugging. If water enters the...
-
06-19-2012, 06:36 PM
Thread: Big Block of Ice
by OhioTech- Replies
- 13
- Views
- 1,342
DONE!!!!!!!!!.Froze my A________ off! -3 deg 20...
DONE!!!!!!!!!.Froze my A________ off! -3 deg 20 ft in air. LIVIN THE DREAM!Turbo torch to cut channels and holes in ice because pan was overflowing with ice up into the coil. Moved hose around...
-
06-11-2012, 08:56 PM
Thread: Big Block of Ice
by OhioTech- Replies
- 13
- Views
- 1,342
Big Block of Ice
Looking for ideas to thaw ice and replace a defective drain pan heater. Coil 20 ft in air. Pan a solid block of ice about 10ft long x 1ftwide x 6in deep . 0deg in room/warehouse. I need to get old...
-
04-26-2012, 09:43 PM
Thread: HVAC guy needing Comm ref Mech Help
by OhioTech- Replies
- 42
- Views
- 1,809
Thanks for the info EngineerDave
Thanks for the info EngineerDave
-
04-26-2012, 09:40 PM
Thread: HVAC guy needing Comm ref Mech Help
by OhioTech- Replies
- 42
- Views
- 1,809
Thanks Eng Dave for info
It looks as though the float on the seperator is hanging up and not allowing the oil to go to the oil receiver. Quoted customer new float assembly,henry oil level control for compressors and oil...
-
04-26-2012, 09:13 PM
Thread: P-66 or motor
by OhioTech- Replies
- 7
- Views
- 584
All electric aside...make sure you are using a...
All electric aside...make sure you are using a ball bearing motor. A sleave bearing will fail.
-
04-22-2012, 08:21 PM
Thread: HVAC guy needing Comm ref Mech Help
by OhioTech- Replies
- 42
- Views
- 1,809
Central Ohio
Central Ohio
-
04-22-2012, 06:04 PM
Thread: HVAC guy needing Comm ref Mech Help
by OhioTech- Replies
- 42
- Views
- 1,809
I would say the suction line is 100-125ft...
I would say the suction line is 100-125ft insulated untill it gets to the accumalator. Accumalator is a ball of ice.The compressor that has failed is thr first one after the accumalator. I will check...
-
04-22-2012, 05:48 PM
Thread: HVAC guy needing Comm ref Mech Help
by OhioTech- Replies
- 42
- Views
- 1,809
OK then 20-25 deg superheat at compressor. I am...
OK then 20-25 deg superheat at compressor. I am confused at the 6 deg at the evaps than was recommended and then 20-25 at the compressor. I guess maybe I should check the total tonnage of the...
-
04-22-2012, 05:40 PM
Thread: HVAC guy needing Comm ref Mech Help
by OhioTech- Replies
- 42
- Views
- 1,809
I am getting replies from all of you so fast I am...
I am getting replies from all of you so fast I am falling behind on your replies. I noticed someone said 6 degrees of superheat on the evaps.
-
04-22-2012, 05:35 PM
Thread: HVAC guy needing Comm ref Mech Help
by OhioTech- Replies
- 42
- Views
- 1,809
No less than 20 degrees superheat? So like 10-15...
No less than 20 degrees superheat? So like 10-15 Just want to make sure on the same page
-
04-22-2012, 05:31 PM
Thread: HVAC guy needing Comm ref Mech Help
by OhioTech- Replies
- 42
- Views
- 1,809
The condensers looked clean. It is mounted right...
The condensers looked clean. It is mounted right above the "shack" the compressors are in. Some genius mounted them there so its like working on an airplane with the props running. I did notice that...
-
04-22-2012, 05:19 PM
Thread: HVAC guy needing Comm ref Mech Help
by OhioTech- Replies
- 42
- Views
- 1,809
The cannister I am talking about is on the side...
The cannister I am talking about is on the side of each compressor. It has a sight glass and an adjustment to control the oil level. It mounts on the compressor where there is normally a sight glass....