  1. Someone will have to contact Tridium Licensing...

    Someone will have to contact Tridium Licensing and order the appropriate BACnet driver.
  2. No, you need to look at the Webs License

    No, you need to look at the Webs License
  3. Go to your license manager in the jace, open the...

    Go to your license manager in the jace, open the license file and make sure it lists Bacnet.
  4. Replies
    22
    Views
    3,120

    Indeed it has been James. I hope all is well with...

    Indeed it has been James. I hope all is well with you.
  5. Replies
    22
    Views
    3,120

    I had the Bobs tools a long time ago but lost it....

    I had the Bobs tools a long time ago but lost it. I would like to have it again as well if anyone could share it.
  6. Replies
    1
    Views
    206

    I have used the T7350 stats with WebVision and...

    I have used the T7350 stats with WebVision and just a regular Jace. WebVision is an appliance jace and you used to be limited to like 12 stats I think. It may be different now. I would use a regular...
  7. Replies
    6
    Views
    612

    Do a search on niagara central for single sign on.

    Do a search on niagara central for single sign on.
  8. Thread: NAE Lon to FX

    by lwarren
    Replies
    14
    Views
    540

    You can change the points to poll only in the Lon...

    You can change the points to poll only in the Lon Link Manager
  9. Thread: NAE Lon to FX

    by lwarren
    Replies
    14
    Views
    540

    You can go to the property sheet of the device...

    You can go to the property sheet of the device config under each device and set the config state back to config online.
  10. Replies
    29
    Views
    1,122

    I don't think your platform daemon is running. Or...

    I don't think your platform daemon is running. Or something is blocking the port.
    See this link, https://community.niagara-central.com/ord?portal:/discussion/DiscussionThread/13383
  11. Replies
    5
    Views
    307

    Use the elapsed active time numeric.

    Use the elapsed active time numeric.
  12. Replies
    8
    Views
    633

    Just go to Echelon's site and download NodeUtil...

    Just go to Echelon's site and download NodeUtil and you can extract it yourself.
  13. Replies
    20
    Views
    1,028

    The station you sent me looks pretty much the...

    The station you sent me looks pretty much the same as the one I got from Hutchey several years ago. It does look like he has renamed some of the nv's and made them custom snvt's. You will have to...
  14. Replies
    20
    Views
    1,028

    Can you send me the station and I will look at...

    Can you send me the station and I will look at it. Email is in my profile.
  15. Replies
    20
    Views
    1,028

    It should certainly have the terminal load nv's

    It should certainly have the terminal load nv's
  16. Replies
    20
    Views
    1,028

    My bad, I just knew I sent it to someone...

    My bad, I just knew I sent it to someone recently. The one I have I got from Hutchey several years ago.
  17. Replies
    20
    Views
    1,028

    It shouldn't be a problem if you are using the...

    It shouldn't be a problem if you are using the VVT Spyder App that I sent you. I have already done this on a job so I know it will work. You just need to link nvoTerminalLoad from the boxes to...
  18. Replies
    20
    Views
    1,028

    Let me dig it up and I will send it to you.

    Let me dig it up and I will send it to you.
  19. Replies
    16
    Views
    1,001

    Good point.

    Good point.
  20. Replies
    16
    Views
    1,001

    I have the Picoscope 2105, im not sure if they...

    I have the Picoscope 2105, im not sure if they still have that model but if they do I don't see any reason why it would not do what you needed for and RS485 network.
  21. Replies
    16
    Views
    1,001

    I have the picoscope. It is a USB scope that you...

    I have the picoscope. It is a USB scope that you run from your laptop. You can record and save the data. It has proven fine for troubleshooting Lon networks for me.
  22. Replies
    5
    Views
    448

    I think you mean Node Clash alarms. This would...

    I think you mean Node Clash alarms. This would indicate a problem on the Lon Network. IE, Not terminated properly, poor wiring installation, bad controller, noise on the network etc.
  23. Replies
    20
    Views
    1,028

    I have the one Hutchey did. I have used it. You...

    I have the one Hutchey did. I have used it. You just have to link the network points nvoZoneData from the boxes to the RTU and nvoAhuData from the RTU to the boxes. Then just set your terminal load...
  24. Replies
    1
    Views
    333

    Yes, I ran into this in July of last year. I have...

    Yes, I ran into this in July of last year. I have done many upgrades since then and have not seen this behavior in every one of them.

    This was the suggestion from Hutchey when I first ran across...
  25. Replies
    9
    Views
    624

    Well I need to clarify. It appears that price was...

    Well I need to clarify. It appears that price was to go from Central to Pro. The price is $299.00 per year for up to 100 computers I think.
  26. Replies
    9
    Views
    624

    I had to start paying for the free version last...

    I had to start paying for the free version last year because of the number of computers we had on it. It was $200.00. Now I see it is going to cost me $1000.00 per year.
  27. Never mind, I yelled at it long enough and it...

    Never mind, I yelled at it long enough and it started working.
  28. I guess I would like to verify that I have the...

    I guess I would like to verify that I have the right pinout connections in the attached image as well.

    454281
  29. Andover Infinity NetController to Jace Setup?

    I am trying to setup my first integration to a Net Controller model 9900 I believe to a jace via the Andover Infinity driver.
    I was able to get the pinout connection to go from the jace's 9 pin...
  30. Thread: FLON ABB Card

    by lwarren
    Replies
    2
    Views
    354

    What is parameter 9802 set to? It should be set...

    What is parameter 9802 set to? It should be set to EXT-FBA.
  31. Replies
    4
    Views
    577

    I have used GMX for several sites as well. They...

    I have used GMX for several sites as well. They do not require SSL connections.
  32. I use the Spyders all the time for plant control...

    I use the Spyders all the time for plant control and have done some pretty complex sequences with them. Not sure what you are trying to do that you cannot find a block for. In regards to the PID on...
  33. Shouldn't be a problem. You should be able to...

    Shouldn't be a problem. You should be able to connect it to the network and do a discover and commission. Then you should be able to proxy out the points. It says they have the XIF file available if...
  34. You got mail.

    You got mail.
  35. Replies
    11
    Views
    739

    Yes, you need one at each end of line. If using...

    Yes, you need one at each end of line. If using the regular Lon resistors, make sure you use the right pair of wires for a double terminated network.
  36. Replies
    11
    Views
    739

    If this is a daisy chain it will need to be...

    If this is a daisy chain it will need to be terminated at each end.
  37. Replies
    11
    Views
    739

    I think you have a comm problem. Is the network...

    I think you have a comm problem. Is the network terminated? Delete one of the devices you cant see. Go to the Lon utilities manager and set the command to "identify" and the Subcommand to "Service...
  38. Replies
    25
    Views
    2,234

    So you are seeing the same issues when connected...

    So you are seeing the same issues when connected with Workbench as you do when connecting via a browser?
  39. Replies
    25
    Views
    2,234

    Well you still haven't stated whether this is an...

    Well you still haven't stated whether this is an issue through the browser, AX or both. Is the px editor installed on the jace?
  40. Replies
    25
    Views
    2,234

    See these two threads. ...

    See these two threads.

    https://community.niagara-central.com/ord?portal:/discussion/DiscussionThread/13171
    https://community.niagara-central.com/ord?portal:/discussion/DiscussionThread/15043
  41. If it is R-22 I have a program object that will...

    If it is R-22 I have a program object that will calculate the saturated refrigerant temp from suction pressure.
  42. You would need a suction pressure transducer and...

    You would need a suction pressure transducer and a strap on sensor.
  43. Use the operator flag on the action slots and...

    Use the operator flag on the action slots and then define the correct permissions in the catagory service for the user.
    If the operator flag is checked, then a user with operator read permissions...
  44. Yes they probably will to re-license it as open....

    Yes they probably will to re-license it as open. However, this problem falls back to the original contractor not Honeywell. We are a Honeywell contractor and we only buy all of our Jaces with the...
  45. Replies
    3
    Views
    327

    If I understand what you are asking let them...

    If I understand what you are asking let them write to a numeric writable that is linked to a GreaterThanEqual block that turns on your cooling call.
  46. Replies
    9
    Views
    751

    Wow, TAC would call you back withing two days? I...

    Wow, TAC would call you back withing two days? I still have a case that I opened in 2005 that i never got a call back on LOL.
  47. Replies
    2
    Views
    382

    Does this 403 have the extended memory? Are you...

    Does this 403 have the extended memory? Are you using the Spyder Tool on this jace? If it does not have the expanded memory then I would say no. If it has the expanded memory but you are using the...
  48. Replies
    9
    Views
    751

    Digo, Web Squad has been in effect since the...

    Digo, Web Squad has been in effect since the beginning of the year. There is a much faster response then going through TAC.
  49. Replies
    4
    Views
    649

    Interesting, I have the same problems except with...

    Interesting, I have the same problems except with Lon.
  50. Replies
    5
    Views
    837

    Yes, he is talking about a C-Bus driver.

    Yes, he is talking about a C-Bus driver.