  1. Replies
    30
    Views
    3,974

    They went the extra mile wiring in overflow safety

    They went the extra mile wiring in overflow safety
  2. Replies
    21
    Views
    6,987

    I likewise would not install any deck above my...

    I likewise would not install any deck above my outdoor units
  3. Replies
    11
    Views
    1,269

    I would check incoming line voltage and voltage...

    I would check incoming line voltage and voltage drop across contacts when the motor starts.
  4. Replies
    6
    Views
    2,920

    I have used three of them so far with no...

    I have used three of them so far with no complaints.
  5. Replies
    122
    Views
    7,889

    Lockout tagout will save your life as well as...

    Lockout tagout will save your life as well as others.There are to many Thomas Edison wannabees out there.Always use the live dead live test when working on anything.Test voltage phase to phase and...
  6. My recourse of action would be to contact the...

    My recourse of action would be to contact the installing company of the unit.I would be a little reluctant to have another brand condenser installed as this would probably void your warranty.It does...
  7. I to like to run my condensate line outside with...

    I to like to run my condensate line outside with the lineset unless it is on a 90 percent gas furnace.It just seems to me on filter changes that pvc pipe exposed to that floor drain could be a...
  8. I would have used a condensate pump on this...

    I would have used a condensate pump on this installation also.I do not really like to have exposed pvc running on floor as it does pose a tripping hazard.As far as the taped joints go its a matter of...
  9. Replies
    36
    Views
    2,734

    I believe one watt is equal to 3.413 btus per...

    I believe one watt is equal to 3.413 btus per hour.I hope this helps in figuring your load requirements on your server room.I also agree with previous post in regards to choosing a Liebert system.
  10. Replies
    41
    Views
    6,356

    I have used sandpaper in a pinch.I do prefer to...

    I have used sandpaper in a pinch.I do prefer to use scotch brite or steel wool.I have never had a problem using any of these on flame sensors.
  11. Replies
    4
    Views
    2,721

    If the customer is happy with that kind of...

    If the customer is happy with that kind of installation you dont need to work for him anyway.
  12. Replies
    10
    Views
    2,464

    Ducane equipment is not bad lower end...

    Ducane equipment is not bad lower end equipment.Like the previous post said its all about the quality of the install.
  13. Thread: Sanyo Models

    by roaddog
    Replies
    2
    Views
    817

    Sanyo customer support 1 800 851 1235 Monday -...

    Sanyo customer support 1 800 851 1235 Monday - Friday 8:30 am -5 pm. hope this helps you .
  14. Replies
    10
    Views
    2,261

    Looks like Taco Bells mexican pizza! lol

    Looks like Taco Bells mexican pizza! lol
  15. You wont go wrong with a Thermopride furnace with...

    You wont go wrong with a Thermopride furnace with a Riello burner.Just as long as load calculation is performed and reputable contractor installs system. Good Luck.
  16. Thread: pwm vs pan

    by roaddog
    Replies
    0
    Views
    442

    I had a class the other night on sanyo mini...

    I had a class the other night on sanyo mini splits, and the literature they gave us spoke of pwm control for low speed operation and pam control for high speed operation.I am familliar with pulse...
  17. I would have a new system installed now.A new...

    I would have a new system installed now.A new unit would make a good selling point.It also would jam you up if a potential buyer insists on having it done.This way is one less thing that they can...
  18. Replies
    9
    Views
    1,001

    With the constant increase in materials I think...

    With the constant increase in materials I think the idea of a 30 day written quote is a good idea.In this business, a companies operating cost is always changing due to material increases and fuel...
  19. Replies
    5
    Views
    909

    This noise may possibly be your unit going into...

    This noise may possibly be your unit going into defrost mode.
  20. Replies
    6
    Views
    846

    Your fan will run until your heat exchanger has...

    Your fan will run until your heat exchanger has cooled down enough to "break" fan switch. Is your thermostat overshooting its set point because of this?
  21. Thread: Fuses

    by roaddog
    Replies
    14
    Views
    1,029

    When I do preventive maintenance on our 480 volt...

    When I do preventive maintenance on our 480 volt lieberts I do not pull the fuse to check them.
  22. Replies
    17
    Views
    1,232

    I tend to agree with the previous post about age...

    I tend to agree with the previous post about age of unit as well as safety issue.I would also look for a company with more documentation on heaters condition and shy away from phone quotes.If...
  23. Replies
    17
    Views
    1,232

    Did any of the companies that inspected your...

    Did any of the companies that inspected your heater use a combustion analyzer with printable results?
  24. Replies
    15
    Views
    3,808

    Oh my!Did they ask you if you could just "patch...

    Oh my!Did they ask you if you could just "patch it up"
  25. Replies
    8
    Views
    714

    In my opinion with a 20 year old system,I would...

    In my opinion with a 20 year old system,I would opt for replacing both units.