  1. Thread: Heat pump

    by pfeifer
    Replies
    17
    Views
    689

    I have several factory reps say let them run no...

    I have several factory reps say let them run no matter how cold

    Sent from my XT907 using Tapatalk
  2. Thread: Heat pump

    by pfeifer
    Replies
    17
    Views
    689

    Heat pump

    I know that there is heat in 10 degree air but what temp if any should a heat pump shutdown and go to the electric air handler which has 15 kV potential. Any thoughts

    Sent from my XT907 using...
  3. Replies
    6
    Views
    587

    yep reliatels are good to go with minor...

    yep reliatels are good to go with minor connection changes/plug changes but older ones u will have to add a board for the tstat and some minor connection/plug changes. y would u want a t-stat u...
  4. if u have replaced the 3-wire pilot assy even...

    if u have replaced the 3-wire pilot assy even the ones new out of the plastic require a little bending/tweaking of the flame diverter so it heats the bimetal good. Even the position of the pilot...
  5. Replies
    12
    Views
    545

    when u made the choice to use the wrong part...

    when u made the choice to use the wrong part knowingly then how did u expect it to work correctly. not having enough load on it is a good possibility but it being faulty also sounds possible also
  6. u could very well have 13 incoming but what...

    u could very well have 13 incoming but what happens when u check it when the valve is open and heating. bet it drops u have volume problem restrictions in the gasline if it doesn't drop then...
  7. Replies
    23
    Views
    1,480

    the substance is from improper combustion and it...

    the substance is from improper combustion and it will and probally has started clogging up things. you need to determine if the gas pressure, venting, restrictor plate, burners clean for good...
  8. Replies
    20
    Views
    1,717

    it sounds like the burners need removed, brushed...

    it sounds like the burners need removed, brushed and blown out. then I would make sure the location of the his was correct. I have had to re mount or to use an ign that warms up prior to gasvalve...
  9. Replies
    11
    Views
    830

    I would say that the deadband should not be set...

    I would say that the deadband should not be set at 7 this will effect the a-c because it thinks it shoud be coming on looking at your temp settings leave the deadband on auto or a lot lower...
  10. Replies
    5
    Views
    594

    What is ur indoor statics. Bet ur coil is...

    What is ur indoor statics. Bet ur coil is plugged. Not correct airflow. Then not correct temperature. What is the super heat/subcooling

    Sent from my XT907 using Tapatalk
  11. Replies
    36
    Views
    14,602

    Sticky: Poll: Where's the poll at. Love to help if I could find...

    Where's the poll at. Love to help if I could find the intended question s

    Sent from my XT907 using Tapatalk
  12. Replies
    36
    Views
    14,602

    Sticky: Poll: I am trying to become a pro member and when I try...

    I am trying to become a pro member and when I try to apply I get a loop. Can some one help

    Sent from my XT907 using Tapatalk
  13. I think u Need to give more information. I never...

    I think u Need to give more information. I never heard of a fitting like this. What's product name. Model. Etc.

    Sent from my XT907 using Tapatalk
  14. U can also install a way to add oil while in...

    U can also install a way to add oil while in service. This should have been done about 3 compressor s ago. Next. Replump system oil doesn't disapear

    Sent from my XT907 using Tapatalk
  15. Replies
    6
    Views
    760

    well ur 2 cents is worth a thousand i have...

    well ur 2 cents is worth a thousand i have sanded and used pene fluid i know that i should put a new one on it going to try and get lucky not messing up the old 1 i was just wondering if it...
  16. Replies
    6
    Views
    813

    This is the Ask Our Pro's forum, and only Pro...

    This is the Ask Our Pro's forum, and only Pro members that have been vetted by the AOPC may post advise, commentary, or ask questions of the OP here.

    You can find the rules for posting and...
  17. Replies
    6
    Views
    760

    not the middle bearing the one right after the...

    not the middle bearing the one right after the pulley before the blower wheel the wheel is the problem and i would like to save this bearing because it is in great shape and the unit is in a...
  18. Replies
    35
    Views
    2,494

    u can involve the local gas provider of the...

    u can involve the local gas provider of the safety issue and they will be forced to pin the meters until the problems r corrected and the residents r safe also the fire dept can help with this...
  19. Replies
    35
    Views
    4,365

    This is the Ask Our Pro's forum, and only Pro...

    This is the Ask Our Pro's forum, and only Pro members that have been vetted by the AOPC may post advise, commentary, or ask questions of the OP here.

    You can find the rules for posting and...
  20. Replies
    2
    Views
    932

    what freeon is it it does sound like txv...

    what freeon is it it does sound like txv issue but u will need to make sure that heat transfer in evap is ok or the reading u r taking will not b accurate
  21. Replies
    6
    Views
    760

    bad blower wheel

    i have a double wheel blower in an old lennox unit that i would like to know how to remove the pillow bearing. It is in good shape and i am not sure if i should separate the bearing from the pillow...
  22. Sticky: i am still waiting for someone to process my...

    i am still waiting for someone to process my request 4 being a professional member

    did i get forgotten sent u all certifications, liciences, epa card , 410, mvac, work history and expirience ...
  23. Replies
    10
    Views
    1,049

    these controls are all basically switches rather...

    these controls are all basically switches rather it is a limit switch or a relay they are a path for current to flow to turn on or off a device. all electronics have paths for things to flow like...
  24. Sticky: want to be a profes. member

    I have had a terrible time with using old computers and viruses but now I have finally bought one that is new and has proper protection.

    I would love to become a pro. member and ask that U please...
  25. Replies
    3
    Views
    626

    i need a new blower motor and a new fan control

    i need a new blower motor and a new fan control