  1. Replies
    12
    Views
    2,632

    Vic pipe

    This may help
    http://www.victaulic.com/Docs/lit/04.01.pdf
  2. Replies
    28
    Views
    4,746

    Look at page #4, Optional accessories list on...

    Look at page #4, Optional accessories list on this link..
    http://www.trane.com/webcache/un/split%20system%20air%20conditioners%20(ss)/product/22-1831-03_12012009.pdf
    Try to get your service company...
  3. Replies
    28
    Views
    4,746

    On page #14 of the litature link I set up. The...

    On page #14 of the litature link I set up. The manufacture(trane) puts enough refrigerant, in unit from factory, to accomadate 15' feet of lines. your unit seems to fall with-in that window. It is...
  4. Replies
    28
    Views
    4,746

    Why was unit installed twice? How much distance,...

    Why was unit installed twice? How much distance, in feet, betwween indoor and outdoor unit?
  5. Replies
    28
    Views
    4,746

    low ambient a/c operation

    http://www.trane.com/webcache/un/split%20system%20air%20conditioners%20(ss)/product/22-1831-03_12012009.pdf this is the product litratue link for your unit,,,the first page states 55F from...
  6. http://www.patentgenius.com/patent/5580238.html...

    http://www.patentgenius.com/patent/5580238.html The inshot burners with low Nox inserts, have had some noise issues..All manufactures are having to deal with this..Trane had a run of L.P. furnaces...
  7. Replies
    3
    Views
    1,434

    Honeywell Mod motor cross-ref PDF

    http://customer.honeywell.com/NR/rdonlyres/5583F336-15A7-4301-BDC0-AD22653CDA20/577/638358.pdf Dont know if this will help....Have local Honeywell supplier that can cross most of that stuff. Repost...
  8. Replies
    6
    Views
    601

    fan control

    Will the fan operate on a call for cooling?
  9. Found picture of discriminated Shemale!

    61352
  10. Replies
    11
    Views
    1,449

    Thanks for the link...About capacitors

    Thanks for the link...About capacitors
  11. Replies
    21
    Views
    38,676

    Oversizing

    With a 2 stage unit, oversizing is not that big of issue, a majority of the time, the unit will be running on low stage. If heat pump, oversizing, may be advantage, with higher capacity, less time...
  12. Replies
    17
    Views
    1,609

    R-22 "Freon"

    I have no fear that the Refrigerant R-22 will around for years, with or with-out, the mandated taxes, cap and pay scheme, or any other new propaganda, the enviromentalist want to tell you....Where is...
  13. Replies
    3
    Views
    624

    First Company

    ....Rheem does'nt make air handlers with hot water coils..
    After looking at their products, it appears that First Company does'nt yet sell outdoor units to match their air handlers, Rudd, produces...
  14. Replies
    13
    Views
    1,274

    Thanks for the link, will help with one of my...

    Thanks for the link, will help with one of my 1947 kewanee problem child, slow to heat, remote radiators! Now I have a answer...
  15. Hot water holds less disolved gases, thus clearer...

    Hot water holds less disolved gases, thus clearer ice?
  16. Disolved gases make ice cloudy, not...

    Disolved gases make ice cloudy, not minerals...Hot water provides clearer ice, does it freeze faster? In some cases yes..That is known as the "Mpemba Effect" see link ...
  17. Replies
    39
    Views
    5,048

    Vent to Small

    I agree with most...field installed errors are usally responsible, Why do some many.. always point to the control board as the problem..Venting to small, drains clogged, not enough ductwork, control...
  18. Replies
    3
    Views
    516

    http://www.trane.com/webcache/un/rooftop%20air%20c...

    http://www.trane.com/webcache/un/rooftop%20air%20conditioners%20(rt)/product/rt-prc030-en_06222007.pdf Look under "Typical Wiring"
  19. The only products I fully trust are CfC's,...

    The only products I fully trust are CfC's, HCFC's, Sporlan filters, acid neutralizers and mineral oil ..I've seen those run 40 years without a compressor failure. Any thing else...
  20. Replies
    12
    Views
    6,402

    Is this a scroll or recipocating? Does it have a...

    Is this a scroll or recipocating? Does it have a discharge muffler? Is this transmitted water or refrigerant piping noise? Is the unit mounted on isolation pads or mounted rigid to the building...
  21. Replies
    7
    Views
    9,059

    Everseen lighting strike a outdoor gas grill with...

    Everseen lighting strike a outdoor gas grill with a shallow copper supply line... Arcing burnt thru the pipe, burst into flames instantly, happened at my nieghbors a few years ago. No damage but he...
  22. Thread: Hoarders

    by superheatrman
    Replies
    46
    Views
    7,779

    Good argument for plastic walmart bags..My wife...

    Good argument for plastic walmart bags..My wife and kids love that show "Hoarders" ..thanks for the post..Ive seen a few as bad.. Pictures just dont transmit the smell..thats what gets me!
    Stll not...
  23. Replies
    10
    Views
    2,982

    Carrier 30gxc Oil pressure problems

    http://www.docs.hvacpartners.com/idc/groups/public/documents/techlit/30g,h-7t.pdf

    Look at page 47, I've encountered oil pressure problems with these skids ever since they were put on the...
  24. HERE TO HELP, NOT THROW ROCKS...

    Share the wealth...that you freely get!
  25. http://www.carlylecompressor.com/Files/Carlyle_Com...

    http://www.carlylecompressor.com/Files/Carlyle_Compressor/Local/US-en/documents/020-611_withCover_LOWRES.pdf
  26. Replies
    61
    Views
    3,807

    Very good descrption. Thank you

    Very good descrption. Thank you
  27. Replies
    24
    Views
    2,044

    Always dry, diluted as recommeded, this will give...

    Always dry, diluted as recommeded, this will give you good coil penetration on thick coils.
    This spray nozzle is the Bomb for Hvac cleaning.
    Light, indistructable, 100% shut off, pin stream to...
  28. Replies
    15
    Views
    6,127

    You need better search engine, or keyword search!...

    You need better search engine, or keyword search!
    All this info is available, FREE, without being pushed around, from Lennox web site.
  29. Replies
    15
    Views
    964

    Residential Talk Not Allowed

    Der shall be no talk of residential repair, on dis site aht anytime.
    Da masses, canot handle, information, which might endanger demselves,
    Thoughts of indivdulism, shall be banded, if we are to...
  30. Replies
    6
    Views
    732

    I think you have 20 ton unit mo.# TTA240. They...

    I think you have 20 ton unit mo.# TTA240. They were only equiped with condensor coil protection as factory option, or field installed. The gaurds are available from Trane.
    They should be mandatory...
  31. Replies
    24
    Views
    2,044

    Those acid/alkaline cleaners are dangerous...Seen...

    Those acid/alkaline cleaners are dangerous...Seen alot of accidents with them over the years.Spill a undiluted gallon in the back of a service van,OMG.. I clean coils daily, this is what I...
  32. Replies
    14
    Views
    1,165

    high amps

    Manually, nearly close suction service valve on compressor body, while monitoring actual suction pressure via crankcase tap. This will act like a EPR(evaporator press. regulator) unloading the...
  33. trane comp. replacement

    I have changed alot of older Trane comp to Copeland...requires some field modifacation..piping, suction acc.,comp. hold down bolts, crankcase heater, capacitor..Usally done only as last...
  34. Replies
    56
    Views
    6,045

    Has anybody tried this stuff ?

    http://www.novatech-usa.net/docs/CRT_Weatherproof_Coil_Shield_Datasheet.pdf
  35. Replies
    56
    Views
    6,045

    Was that thing running like that??? with a water...

    Was that thing running like that??? with a water spinkler subcooling it??
  36. Replies
    17
    Views
    1,299

    can you post link for tool?

    can you post link for tool?
  37. these work...

    these work well...http://www.johnstonesupply.com/corp/OnlineCatalog/ProductDetails/tabid/1780/Default.aspx?Product_Code=R55-713
  38. Replies
    8
    Views
    3,452

    McQuay of georgia, marley cooling tower sales rep.

    McQuay of georgia, marley cooling tower sales rep.
  39. Replies
    6
    Views
    1,718

    Quoted 2.5 ton ,1/2 HP,4.3 amps GE ECM blower...

    Quoted 2.5 ton ,1/2 HP,4.3 amps GE ECM blower motor and air handler control board for 14 year old carrier, today Our cost was 1/2 of a new VS air handler....Offered to change it to PSC motor with...
  40. Replies
    21
    Views
    1,497

    Your furnace is now qualified to be posted on the...

    Your furnace is now qualified to be posted on the WALL OF SHAME..sorry,no prize...What is Tittle 24?
  41. Replies
    5
    Views
    1,002

    carrier, payne, day night, tempstar,heil,...

    carrier, payne, day night, tempstar,heil, kenmore,bryant are all ICP brands, similar model# made in differnt plants, Try goodman, trane, lennox, they are of other manufactures...
  42. Replies
    32
    Views
    2,876

    Page 1, #6...

    Page 1, #6 tighhttp://www.dodge-pt.com/pdf/instruct_manuals/bearings/ball/499498.pdften to the direction of shaft rotation..http://www.dodge-pt.com/pdf/instruct_manuals/bearings/ball/499498.pdf
  43. Replies
    10
    Views
    758

    OEM economizer package may be cheaper than hot...

    OEM economizer package may be cheaper than hot gas bypass, Sell the enegy savings..
  44. Replies
    10
    Views
    758

    Too small of orfice... need to get your superhest...

    Too small of orfice... need to get your superhest up.. what did the oil look like?Was the old compressors shorted,grounded or open?
  45. Replies
    14
    Views
    2,628

    That secondary is under warrenty, Did you replace...

    That secondary is under warrenty, Did you replace it ?
  46. Replies
    10
    Views
    828

    DITTO...

    DITTO...
  47. Need more info, is water heating is a large...

    Need more info, is water heating is a large portion of that electric bill? How much is the bill in april or oct.? dual fuel gas/electric will reduce a part of total electric costs, how much... is a...
  48. Replies
    12
    Views
    6,073

    144F supply air

    144F still gives you 75F temp. rise appears to still be running to hot. The temp rise is on the manufactures label . 45F-70F is standard on most 80% furnaces. Add that ductwork.
  49. Replies
    12
    Views
    6,073

    Sounds like your 11 year old furnace is low on...

    Sounds like your 11 year old furnace is low on air flow and the evaporator is clogged with dirt. A temperature rise measurement will show this.:)
  50. Replies
    27
    Views
    2,811

    Trane Centravac Manual

    This may answer some of your questions
    http://www.trane.com/Commercial/Uploads/Pdf/1050/CDHF-SVU01C-EN_04012005.pdf
    I appolgize for the atitude of some, they do not reflect the opinions of all....
Results 1 to 50 of 160