  1. Thread: Serously?

    by talktowags
    Replies
    13
    Views
    1,937

    Success !!!

    Success !!!
  2. Replies
    23
    Views
    833

    Tube heater.

    Tube heater.
  3. Replies
    9
    Views
    605

    The switch is likely doing what it is designed to...

    The switch is likely doing what it is designed to do. Have a qualified tech check for vent blockage, secondary HE and temp rise. not sure why your not getting a flash code ? but with Nordyne anything...
  4. Replies
    35
    Views
    1,839

    As advised before, take all wires off board...

    As advised before, take all wires off board before crossing out R & W Had 2 where stat was causing that problem. Also had a goodman and turned out to be short in the ignitor.
  5. Replies
    10
    Views
    854

    I think you answered your own question. Lets see,...

    I think you answered your own question. Lets see, you have a 28 year old Rheem ???
    Seriously, go with the contractor you feel most comfortable with.
  6. Replies
    2
    Views
    235

    Welcome

    Welcome
  7. Welcome. Lots to learn here and lots you don't...

    Welcome. Lots to learn here and lots you don't need to know. LOL
  8. Replies
    3
    Views
    160

    Welcome, jump in !!

    Welcome, jump in !!
  9. Replies
    13
    Views
    1,033

    I started my Company in 1994 and new pretty much...

    I started my Company in 1994 and new pretty much nothing about the industry. I hired an experienced tech and a helper to get started. I looked after sales, books, picking up and delivering materials...
  10. Replies
    2
    Views
    416

    If you have delayed ignition for whatever reason...

    If you have delayed ignition for whatever reason you may get a bit of raw gas passing through system on start up. Check burners and travel pilot. If HSI not getting hot enough, raw gas can pass...
  11. Replies
    23
    Views
    2,278

    With a job like yours, one would think you could...

    With a job like yours, one would think you could afford a Sunday service call. ??
  12. Replies
    7
    Views
    930

    Sounds like it is a stat issue. What kind of stat...

    Sounds like it is a stat issue. What kind of stat are you using ? Older mercury stats have a heat antisipator adjustment. Best to replace if this is the case.
  13. There is no way stove is operating properly with...

    There is no way stove is operating properly with 1.5" wc. You have 12" before or after reg on the house ?? as stated above, you may be double reged. How old is the unit ? gas line could be sludged up.
  14. Replies
    25
    Views
    2,155

    Why not ask some of the guy's you work with.?? Or...

    Why not ask some of the guy's you work with.?? Or throw it around next time your at the supply house.?? DIY ??
  15. Where is the Harthman ?? Good luck with a...

    Where is the Harthman ?? Good luck with a responce from TSSA I would cap & investigate further. Get Irving to tell you why and also what is the fix and who is paying for it. I would want some...
  16. Thread: Wrong way

    by talktowags
    Replies
    6
    Views
    1,703

    What do you charge to install wrong way ???

    What do you charge to install wrong way ???
  17. Replies
    69
    Views
    4,714

    Are you working for a company ? if so maybe ask...

    Are you working for a company ? if so maybe ask that a senior tech assists you on this one. Your messing with s**t that can and most likely will shorten your career. 13.5 out ?? I hope that is a...
  18. Thread: York help

    by talktowags
    Replies
    3
    Views
    695

    No P # on switch. Guess I will call York. Thanks...

    No P # on switch. Guess I will call York. Thanks for the input.
    G
  19. Thread: York help

    by talktowags
    Replies
    3
    Views
    695

    York help

    Anyone know what pressure switch closes at on a York. Model # P9QDD12N09501A. Think about 22 yrs old. Pulling 1.33 thinking that is borderline. ????
    Thanks in advance.
  20. Replies
    24
    Views
    2,740

    While I appreciate your input, you might want to...

    While I appreciate your input, you might want to read all the posts. Water in the trap ?? I hope so. A blocked trap will prevent ignition, but only after inducer starts. Any other thoughts ??
  21. Replies
    24
    Views
    2,740

    There is no way to wire board wrong. Only spade...

    There is no way to wire board wrong. Only spade connections are for the transformer.
  22. Replies
    24
    Views
    2,740

    Sorry I am late getting in. 120v supplied to the...

    Sorry I am late getting in. 120v supplied to the board is through the molex connector. I have 24v at R. I have 120v at eac and motor is fine. No power to 5 pin molex when w is powered. I wired...
  23. Replies
    24
    Views
    2,740

    I am getting no power to the plug from the board....

    I am getting no power to the plug from the board. I put old board back in and I got my fault codes again. New board nothing. Will go at it again on Monday. Thanks for your input.
  24. Replies
    24
    Views
    2,740

    All 3 jack plugs are tight and yes I have 24v...

    All 3 jack plugs are tight and yes I have 24v from tx. polarity is correct.
  25. Replies
    24
    Views
    2,740

    Goodman Res. furnace help

    Working on a Goodman Model # GMV90905 DXA. Powered up unit, called for heat and board immediately gave a 3 flash code. ( Low fire p.s. stuck open ) inducer never started switch should be open ?? Took...