  1. Thread: Grasslin

    by icexprt
    Replies
    20
    Views
    1,528

    Paragon 8145-20 and 8145-00 are what I keep on my...

    Paragon 8145-20 and 8145-00 are what I keep on my truck and use....just don't trust those electronic jobbies too much!!! I do have to admit though, for a cooler off cycle type of defrost, the...
  2. Replies
    1
    Views
    445

    Do you have the full model number? It looks like...

    Do you have the full model number? It looks like the "I" series machines take a different board from the "X" series machines.... as in IAC-322 or XAC-322. I may have a used board for you.
  3. Replies
    33
    Views
    2,541

    I agree with this. Does the unit have a...

    I agree with this. Does the unit have a headmaster type of head pressure control? If so, you are probably low on charge and at night when the outdoor temp drops and the headmaster starts stacking...
  4. Replies
    28
    Views
    1,771

    The hot water migration is your problem. Hoshi's...

    The hot water migration is your problem. Hoshi's thermisters almost NEVER go bad, not to say it can't happen.... We have worked on Hoshi's every day for 19 years and I can count on one hand how many...
  5. Replies
    31
    Views
    3,079

    Dump valve leaking by sometimes....trash was...

    Dump valve leaking by sometimes....trash was stuck in dump valve and finally got freed and flushed down drain so now it works.
  6. Most medium temp condensing units use ac...

    Most medium temp condensing units use ac compressors....(R-22 that is) Icemeister is steering you right. It can be made to work, but after all the time and parts and labor to set it up correctly,...
  7. Replies
    7
    Views
    1,074

    Muriatic acid works wonders cleaning those iron...

    Muriatic acid works wonders cleaning those iron deposits off! Do in well ventilated area, spray it on, hose it off, done! If you've never used it before, you'll be amazed!
  8. Replies
    20
    Views
    1,919

    Sounds like blocked discharge line or supply...

    Sounds like blocked discharge line or supply house gave you wrong voltage replacement? You have checked volts already I assume? Good luck with it!
  9. Replies
    4
    Views
    595

    I was wondering if there were any of those still...

    I was wondering if there were any of those still around working! I too cut my teeth on those and the C models before them. Haven't come across one still working in many years!
  10. Make sure the drain is clear and flowing...

    Make sure the drain is clear and flowing properly, drain line heater (assuming this is a freezer) is installed and functioning. Have seen water left over in drain pan at the end of defrost get kicked...
  11. Replies
    40
    Views
    3,398

    Glad you got it solved! The first one we saw...

    Glad you got it solved! The first one we saw took us several trips over a couple of days to figure out also! I guarantee you'll never forget about it and if you ever see it again you'll go right to...
  12. Replies
    40
    Views
    3,398

    Maybe I'm using the wrong term to describe the...

    Maybe I'm using the wrong term to describe the part I'm referring to.... Refrigeration Research calls it a "subcooling heat exchanger". I've attached a picture... I hope it works...first time posting...
  13. Replies
    40
    Views
    3,398

    Does the system have a heat exchanger installed?...

    Does the system have a heat exchanger installed?

    The more I think about this, the more convinced I am that you probably have a heat exchanger on that system and it is leaking internally, dumping...
  14. Replies
    40
    Views
    3,398

    Is there a heat exchanger mounted in the...

    Is there a heat exchanger mounted in the liquid/suction line? Have seen them leak internally and bleed liquid right into the suction line. Those were fun to diagnose!
  15. Replies
    14
    Views
    1,429

    Either it is plumbed to a hot water source or hot...

    Either it is plumbed to a hot water source or hot water is migrating over to the cold water side and getting to the machine.
  16. Replies
    48
    Views
    4,973

    Look for oil, look for oil, look for oil!!! This...

    Look for oil, look for oil, look for oil!!! This includes moist looking dirt or dust stuck to some part of the system. Start with a good flashlight and your eyes and brain, spending ample time...
  17. Replies
    13
    Views
    1,995

    Check all switches in the control circuit to the...

    Check all switches in the control circuit to the contactor coil. Usually when we run into this it is either short cycling as already stated, or a problem with a pressure switch where the switch...
  18. Replies
    28
    Views
    4,618

    Yea,thanks!.....I'm glad I made it out of that...

    Yea,thanks!.....I'm glad I made it out of that ordeal ok....I don't know what the concentration of ammonia was by ppm in the room that night, heck I was just a kid at the time! I just know that there...
  19. Replies
    28
    Views
    4,618

    When I was 18 I was working one night in a small...

    When I was 18 I was working one night in a small equipment room on a Vogt P-24 ice machine charged with 800 lbs. of ammonia when there was a sudden release of it's entire charge in liquid form from...
  20. Replies
    7
    Views
    2,037

    I agree.....clean it first....I don't believe too...

    I agree.....clean it first....I don't believe too much in the "dump in cleaner and run the auger a while" type of cleaning. Pull it apart and clean/inspect it. It's not too hard to do. Sure it...
  21. Replies
    14
    Views
    2,931

    Is the water distribution system clean? Make sure...

    Is the water distribution system clean? Make sure evey row of every evap. is getting water flow to make cubes.....Hoshizaki brings in "X" amount of water (enough for one batch of ice) at the...
  22. Replies
    6
    Views
    1,109

    I'm not sure if this will pertain to your...

    I'm not sure if this will pertain to your problem, but years ago I dealt with a similar problem involving compressor oil loss on a Vogt P-24 ammonia ice maker that caused many sleepless nights and...
  23. Replies
    3
    Views
    1,777

    The Mycoms I am familiar with on Vogt ice...

    The Mycoms I am familiar with on Vogt ice machines use oil pressure to back the unloaders off. When the compressor is off, the unloaders have a spring that keeps them in the unloaded position holding...
  24. Replies
    49
    Views
    3,292

    Ditto that!

    Ditto that!
  25. Replies
    15
    Views
    2,516

    Yea, I'm with you on that....I'm not going to...

    Yea, I'm with you on that....I'm not going to blow up on him over this....he's had a string of needless callbacks recently and needs a stern talking to...maybe if I handle it right he'll get his...