    The 117U4129 is a good number for a fractional...

    The 117U4129 is a good number for a fractional starter relay. You should be able to get it Next day from you wholesaler.
    ...
  2. Replies
    17
    Views
    1,758

    twophase, I have some thoughts on this. Tried to...

    twophase, I have some thoughts on this. Tried to PM you but could not. PM me with contact info.
  3. Replies
    21
    Views
    2,384

    1.5 depending on the coil design is between .051...

    1.5 depending on the coil design is between .051 and .053
    1 depending on the coil design is between .040 and .042
  4. Replies
    4
    Views
    421

    Three error's caused this crash. nose up in...

    Three error's caused this crash. nose up in stall warning.(Wrong and basic for every plane) Fight the auto correction (Basic for every airplane) Remove flaps (Wrong for every airplane. This has...
  5. Replies
    76
    Views
    7,066

    Make sure the piston is installed facing the...

    Make sure the piston is installed facing the correct direction.
  6. Replies
    76
    Views
    7,066

    Your orifice should be about a 79 for R22 or a 78...

    Your orifice should be about a 79 for R22 or a 78 for 410A.
  7. Thread: Condenser Noise

    by louiee
    Replies
    2
    Views
    359

    Condenser Noise

    What percentage of new installs is the noise of the condenser a consideration to the home owner? Is the homeowner willing to pay more for a quieter condenser or will they just choose another brand?
  8. Replies
    9
    Views
    708

    If replacing them is an option do it.

    If replacing them is an option do it.
  9. We should soon see a major change in the way data...

    We should soon see a major change in the way data centers are cooled. The current method of cooling the data center air to remove heat from the processors is not effecent. Removing the heat from the...
  10. Thread: Trane TXV???

    by louiee
    Replies
    6
    Views
    1,858

    B133546-P12 is the Trane factory part number....

    B133546-P12 is the Trane factory part number. This valve should work fine for you.
  11. Thread: Valve porting

    by louiee
    Replies
    11
    Views
    906

    attach a pic of the valve and I can tell you...

    attach a pic of the valve and I can tell you either it is a back seating valve where about 10% have a valve core or just a front seat and would have a valve core.
  12. Replies
    66
    Views
    2,948

    So, do you think it will affect consumer...

    So, do you think it will affect consumer behavior? Is the $1500 enough to influence the buyer?
  13. Replies
    66
    Views
    2,948

    True on that.

    True on that.
  14. Replies
    3
    Views
    460

    CO2 systems R644

    Currently there is a push in Europe for Co2 systems. What are the thoughts of using Co2 in North America?

    There is a forum to follow the developments R744.com. if anyone wants to read up on it
  15. Replies
    66
    Views
    2,948

    rossb, That is our government at work. Why do...

    rossb,
    That is our government at work. Why do you think the tax code is as long as it is.

    They don't make things clear.
  16. Replies
    66
    Views
    2,948

    Ya, I hope so as well, for all of you and I. I...

    Ya, I hope so as well, for all of you and I. I wish I didn't have to forecast but that is life. With the change to 410A combined with this, makes for some uncertanity.
  17. Thread: Trane TXV???

    by louiee
    Replies
    6
    Views
    1,858

    What is the part number of the valve? What...

    What is the part number of the valve? What manufacture made the valve? There should be a bar code on the side of the valve with the manufacture part number and the trane model number
  18. Replies
    66
    Views
    2,948

    Mr. Bill, I don't sell systems, I make the...

    Mr. Bill,
    I don't sell systems, I make the control products for the OEM's. I am trying to develope a forecast for the mix of products built. Will consumers be more willing to move up in SEER for...
  19. When i started in this industry most OEMs tested...

    When i started in this industry most OEMs tested for leaks using air under water and looking for a buble. This can be very unreliable as it is dependent on a person to watch for that bubble. Now...
  20. Replies
    9
    Views
    600

    sounds like a lot of custom work. You should...

    sounds like a lot of custom work. You should post some pics. I would expect bettere control of SH with the 4 TXVs vs. 2.
  21. @ the Tran web page you can watch a vid of the...

    @ the Tran web page you can watch a vid of the spine coil getting produced. An aluminum tube coil is also less likey to leak from formicary corision caused by POEs in the 410A
  22. Replies
    9
    Views
    600

    What are you using for distributors with the 4...

    What are you using for distributors with the 4 10T TXVs. Are they hot gas bypass or just straight nozzle or venturi?
  23. The most efficient designed coil for a condenser...

    The most efficient designed coil for a condenser in straight A/C is a micro channel. However, when they are used as a heat pump they cause several issues, with the two biggest being water shed and...
  24. Replies
    66
    Views
    2,948

    Effects of the new Stimulus Package

    The question is for all those who sell, and install new residential systems. Wheather it be GEO, ASHP, AC, PTAC or what ever,

    What effect in product mix do you expect to see in the months ahead...
  25. Replies
    17
    Views
    1,620

    I would chose LG or Media. Gree and AUX can be...

    I would chose LG or Media. Gree and AUX can be very low cost.