    Thank you Sometimes struggling and figuring...

    Thank you Sometimes struggling and figuring out what is really wrong by yourself is so much more rewarding

    If you think no one will notice that you put the old board back in the box Guess...
  2. Replies
    3
    Views
    1,622

    Lennox G40UH furnace issues

    I have a Lennox G40uh furnace the initial call was heat would not run when Tstat called but if you reset with disconnect it would light but not again. The lights showed bad board I replaced the board...
  3. Replies
    16
    Views
    2,086

    Did you check the pilot for excess soot?These...

    Did you check the pilot for excess soot?These units will soot up if they run an
    extended low fire .also that sheet metal on the combustion is necessary
    TRUST ME
  4. Replies
    21
    Views
    5,874

    I have a water treatment plant that cant keep...

    I have a water treatment plant that cant keep freon inside their units I found a company called bronze glow coatings
    I think that is the right name they also give a 5 or ten year warranty .If Iam...
  5. Replies
    13
    Views
    2,591

    there is a bms system that makes a relay and also...

    there is a bms system that makes a relay and also resets the da setpoint by offsetting the djm signal
  6. Replies
    13
    Views
    2,591

    Ihave been over the gas side even today ,all is...

    Ihave been over the gas side even today ,all is where it should be .started checking the line side at panels.
    Checked amps on the main ground wire at main buss panel and found 8 amps (curious)....
  7. Replies
    3
    Views
    1,184

    Maybe I should go back to grammer school to learn...

    Maybe I should go back to grammer school to learn how to write sentences.I am looking for help locating a 410a hot gas bypass valve
    THANKS
  8. Replies
    13
    Views
    2,591

    I have an Engineered Air make up air unit that...

    I have an Engineered Air make up air unit that has flame failure during specific times between 11:00 and 2:00 pm
    almost every day. I have checked and set the combustion a couple of times.I have yet...
  9. Replies
    3
    Views
    1,184

    I need help finding a hot gasvalve for 410a...

    I need help finding a hot gasvalve for 410a Sporlan and danfoss have the but lead time is long