09-12-2012, 09:48 AM
- Replies
- 13
- Views
- 960
Running a 7 cfm JB Vacuum pump over night
Does anyone see a problem with running a 7 cfm vacuum pump over night ?
the med. temp beverage cooler was loaded with moisture, located leak, did a triple evac. replaced drier & site glass ...ran... -
10-16-2008, 05:18 PM
Thread: Scottsman Ice Machine
by dismas66- Replies
- 25
- Views
- 2,043
amazing
who would of dah
changing out parts..
water pressure in the bldg.
no wonder I'm all grey:D -
09-28-2008, 12:59 PM
Thread: Koshizaki Ice Machine
by dismas66- Replies
- 1
- Views
- 473
Koshizaki Ice Machine
Got a service call....to a Sports Pub.,.,.
Ice machine filthy...
has not been maintained...
kind of rusty...with the refer stuff....
been buried with hvac..
could not make out the model 3....due... -
07-27-2008, 09:12 PM
Thread: Goodman 2 Ton Air Handlers
by dismas66- Replies
- 5
- Views
- 431
Beenthere... I do not know...tehx13 blower...
Beenthere...
I do not know...tehx13 blower motor
But...many of the Amana/ Goodman AH's
have a spped option on the board....
it's just a matter of swapping wires...
I ran into one on... -
07-27-2008, 08:51 PM
Thread: Goodman 2 Ton Air Handlers
by dismas66- Replies
- 5
- Views
- 431
Goodman 2 Ton Air Handlers
Has Anyone run into the Goodman air handlers....that do not have the fan Speed Control ?
Some Do have the Speeds on the boards.....some do not:( -
07-27-2008, 08:08 AM
Thread: Choosing a boiler...
by dismas66- Replies
- 22
- Views
- 1,079
BUDERUS GB-142 95 % effecient Much Better...
BUDERUS
GB-142 95 % effecient
Much Better then the Ultra
JMO:cool: -
07-19-2008, 06:16 AM
- Replies
- 1
- Views
- 591
2 Story House 1 Air Handler on 1st floor....1 on 2nd floor
:confused:??
O.k.
Now...I keep hearing different things about ...only using one air handler in the basement ...to cool the entire house..:eek:
zone dampers anyone ?:mad:
I have found in my...... -
07-11-2008, 03:53 PM
Thread: PVC Tricks to Making it Screw in
by dismas66- Replies
- 18
- Views
- 962
every-thing is PVC:cool:
every-thing is PVC:cool:
-
07-11-2008, 12:16 PM
Thread: PVC Tricks to Making it Screw in
by dismas66- Replies
- 18
- Views
- 962
PVC Tricks to Making it Screw in
Tying in A sewage injector..pump...to the existing 4" PVC Pipe
the New Male Adapter...Trying to Screw it all the way in to the
existing Female Adapter...
Got it about 1/2 way..IN
..can... -
07-03-2008, 06:02 PM
- Replies
- 3
- Views
- 551
calc cu...lateee
2 x 4 consruction......Catherderal ceiling
R-13 insulation
flolors are pergo..
there is a picture on the wall:D -
07-03-2008, 04:25 PM
- Replies
- 3
- Views
- 551
Sizing up a 18 x 18 3 sided Sunroom with Skylight
Home-owner is...looking to Heat & Cool &
wants a heat pump
Mini Split Ductless..
wants....mostly Cooling...leaves for Florida ..in October (snowbird)
the..3 sided sunroom....has..glass on... -
07-01-2008, 11:53 AM
Thread: Sewage Injector Pump Venting
by dismas66- Replies
- 7
- Views
- 637
Not enough air blowing out of the vents
Got a call over the weekend.....the lady ..whos the sister of my friend Dave...
calls me ...and claims...there is not enough air coming out of the vents...but...the blower is running at the air... -
06-30-2008, 03:31 PM
Thread: Sewage Injector Pump Venting
by dismas66- Replies
- 7
- Views
- 637
Venting
Do you think..:confused:
.I may get some sewage...gases,,
:eek:,,if dad...takes a dump..:eek:
:confused:...and there a north-west wind ? -
06-30-2008, 02:54 PM
Thread: Sewage Injector Pump Venting
by dismas66- Replies
- 7
- Views
- 637
Sewage Injector Pump Venting
Installed a sewage injector pump...in the basement floor...
everything is tied in ....
but the Vent....
Was hoping....
I would not have to drill through...3 floors & the roof ..to vent:eek:... -
06-27-2008, 08:32 AM
Thread: Oil Boiler Replacement Suggestions
by dismas66- Replies
- 15
- Views
- 2,142
It is a storage tank.that the Boiler feeds hot...
It is a storage tank.that the Boiler feeds hot water too...
it stores Hot water....
tankless coils are useless ...unless you shower once a week :o
lol
depending on your... -
06-27-2008, 08:28 AM
Thread: Oil Boiler Replacement Suggestions
by dismas66- Replies
- 15
- Views
- 2,142
the plastic is Pex....it is the alternative to...
the plastic is Pex....it is the alternative to Copper which is close to 4.00 a lbs..
it is made for heat...used often in todays world..due to the high cost of copper..and labor;) -
06-27-2008, 08:19 AM
Thread: Oil Boiler Replacement Suggestions
by dismas66- Replies
- 15
- Views
- 2,142
Oil Heat Is Best
You Do The Math....
Whats it going to cost ...UP FRONT...to Convert ?
What are the savings.....Long Term ?
If it was me...suck it up....
throw in a indirect....for 2K
and be done...
You... -
06-27-2008, 08:13 AM
Thread: Oil Boiler Replacement Suggestions
by dismas66- Replies
- 15
- Views
- 2,142
I am assuming you have a tankess coil....inside...
I am assuming you have a tankess coil....inside your boiler.....why not
have a indirect installed....off of your existing boiler.....If your boiler ..is only 15 yrs old...whats the problem ?
I... -
06-27-2008, 07:49 AM
Thread: Hack Job=Dead Apprentice
by dismas66- Replies
- 179
- Views
- 9,003
Sad, Sad, Story:( Sadly enough....many...
Sad, Sad, Story:(
Sadly enough....many states do not require licenses...for electrical...
In Taxachusetts...you need a license...for everything !
In New Hampshire..."live Free Or Die"... -
06-27-2008, 07:27 AM
Thread: Riello BF5 or F5 burner?
by dismas66- Replies
- 28
- Views
- 3,287
Riello
Unless your installing a Buderus....then riello is good:cool:
But...if you going with a Weil Mclain Pin Boiler....I would go with the Carlin EZ-1
burner...they burn clean ...with the Mclains:D -
06-27-2008, 07:20 AM
Thread: Oil Boiler Replacement Suggestions
by dismas66- Replies
- 15
- Views
- 2,142
Oil Heat Is Best
OIL HEAT IS BEST.....Have You Ever Looked At the Flame in A Combustion Chamber..It heats twice as fast then Natural Gas...
Get Your self a Buderous Boiler / With A Riello Burner...
and Stick with... -
06-24-2008, 07:26 AM
Thread: Messed up service call
by dismas66- Replies
- 39
- Views
- 1,541
bi flow
you may want to consider...working for a contractor...a few more years....get some more experience under your belt....before taking on work...you may run into some litigation down the road...:eek:
-
06-23-2008, 05:35 PM
Thread: American Standard Condensing Unit
by dismas66- Replies
- 5
- Views
- 836
American Standard Condensing Unit
Found a used 2 Ton Condensing Unit
For Sale.....the lady selling it claims ..it's only 5 yrs...old
she doesn't...know the s.e.e.r rating :confused:
any one know what this condenser ... -
06-23-2008, 04:58 PM
Thread: April aire humidifier
by dismas66- Replies
- 7
- Views
- 469
Humidifier...duct to supply
O.K.
I took a look at the manuals.:confused:...
.......... IF...I attach the Aprilaire..mod #550
to the return plenu.....then off of the
6" collar...
take a 6" 90 26 g.:cool: -
06-23-2008, 07:46 AM
Thread: April aire humidifier
by dismas66- Replies
- 7
- Views
- 469
April aire
Model # 550:cool:
I had it tied into the supply plenum....
but now ....witht he cased coil.....no room.....So it will be placed on the Return plenum....
Should I get the same results ?
...