Search:

Type: Posts; User: fd3687

Search: Search took 0.01 seconds.

  1. Replies
    45
    Views
    39,998

    That's in the last 6 months.

    That's in the last 6 months.
  2. Replies
    45
    Views
    39,998

    They no longer carry Quietside.

    They no longer carry Quietside.
  3. Replies
    45
    Views
    39,998

    Check out their BBB rating @...

    Check out their BBB rating @ www.bbb.org/quietside
  4. Replies
    45
    Views
    39,998

    Never Again! Getting parts for these units are...

    Never Again! Getting parts for these units are like pulling teeth! Older water heaters didnt come with freezer protection, heat exchangers froze and cracked. Could build a better unit with Lego.
  5. Replies
    12
    Views
    726

    Party Time in Chicago

    Check out division street or the magnificent mile for a good time. Both can be reached with the subway system (a little sketchy and about 30min travel time) Mid week the magnificent mile is a...
  6. Replies
    12
    Views
    726

    At the same time its an exclusive market, not...

    At the same time its an exclusive market, not many techs know how to service ult's. Haven't worked on a cryo unit yet, but they're becoming more prevalent with stem cell research heating up. FYI if...
  7. Replies
    12
    Views
    726

    Email Address

    Hey 94blowncobra, whats your email adress?
  8. Replies
    2
    Views
    378

    Medical Refrigeration Dealers Wanted

    Please read the forum rules, if you want to advertise here, you must purchase an ad.
  9. Replies
    22
    Views
    5,501

    Therm58

    Hey therm76, the cold headers you're talking about, look at the diameter of the tap that comes out. The new ones are wider at the back of the tap and have a rolled connection, thats the only...
  10. Replies
    22
    Views
    5,501

    There biggest failure we have with these boards...

    There biggest failure we have with these boards is that they will indicate that the pressure switch is closed b4 start up or that there is an issue with the ignitor. There are no issues with the...
  11. Replies
    10
    Views
    1,319

    The unit will go into defrost every 34 min if...

    The unit will go into defrost every 34 min if there is no ice sensed on the coil. If ice is sensed on the coil it will immediately go into defrost. The way the defrost shuts off is by sensing the...
  12. Replies
    22
    Views
    5,501

    Must be an installer

    Ya our installer have put in tons of G51 as well and never seen a board failure. The reason they've never seen one is because us service guys are the ones going buy finding the problems. I have...
  13. Replies
    22
    Views
    5,501

    Lets cross our fingers!

    I've changed so many of the newer G51 surelight boards its not funny. Everytime I go to the lennox warehouse there's a huge pile of returned boards. Hopefully their new-04 series has corrected all...
  14. Replies
    4
    Views
    713

    It turned out that the valve that I changed was...

    It turned out that the valve that I changed was also a dud. Quality!
  15. Thanks, will do.

    Thanks, will do.
  16. Keeprite pressure switch hose filling with water, why?

    Hey everyone, Im a hvac/r tec and i have a bit of a head scratcher. Im working on a mid efficiency keeprite. The pressure switch hose is filling up with water every few days. I think the issue is...
  17. Cheap Chinese Motors

    Just installed one last night, noticed that Goodman is still using the crapy chinese motos. They had a bad bunch of them 2 years ago. I still like the Lennox equpiment the most however is some is...
  18. Replies
    22
    Views
    5,501

    Ya I attended the G71 seminar about two months...

    Ya I attended the G71 seminar about two months ago and its was really intresting. Question is, will this new system really offer that much more benifit compared to the G61.

    About the lining in...
  19. Replies
    22
    Views
    5,501

    1

    1
  20. Goodman AC's have changed a bit

    I've noticed that the goodman ac's are not using the parker service valves anymore. I perfer the Parker valves over these generic valves only because alot of installers are not reading the...
  21. Replies
    22
    Views
    5,501

    Problems with Lennox G51

    Hi there everyone I work for a lennox dealer and I thought I would fill you in on some of the issues we've had with the Lennox G51.
    Well let me start with propane aplications. Depending on the...
  22. Thread: Chinese ULT

    by fd3687
    Replies
    29
    Views
    3,123

    Its sucks

    It really pisses me off that this is the situation. I always thought that the governments elected were supposed to represent the people. I would think that the majority of the people would want...
  23. Thread: Chinese ULT

    by fd3687
    Replies
    29
    Views
    3,123

    Let me rephrase this. Americans should have...

    Let me rephrase this. Americans should have acess to FREE BASIC HEALTH CARE. If France, Italy, England, Germany, Canada and Spain can offer FREE BASIC HEALTH CARE to its citizens then I see no...
  24. Thread: Chinese ULT

    by fd3687
    Replies
    29
    Views
    3,123

    Human Rights

    Human rights is a big issue that I need to adress. Everyone condems China about their policies on human rights. They are slowly making changes to improve this issue but they have a long way to go. ...
  25. Thread: Chinese ULT

    by fd3687
    Replies
    29
    Views
    3,123

    Big Change!

    We've tested these units for three months and I'm extremely happy to report that these units are of excellent quality and have out performed our Sanyo test unit. We find that the accuracy of our...
  26. Thread: Chinese ULT

    by fd3687
    Replies
    29
    Views
    3,123

    Well we'll find out how good they are. Both...

    Well we'll find out how good they are. Both companies are the two largest distributers in china and from what I've read they are also being used in German Hospitals.
  27. Thread: Chinese ULT

    by fd3687
    Replies
    29
    Views
    3,123

    Samples

    I've order two samples, one from haier the other from meiling. Deliver will be in July. Both use danfoss compressors.
  28. Replies
    11
    Views
    2,459

    System design is key to humidiy removal. Does...

    System design is key to humidiy removal. Does your furnace have a varaible speed motor? Do you have a t-stat with humidity control. What is the ductwork lay out like in your home? Is you attic...
  29. Replies
    31
    Views
    13,327

    Neither a good choice

    Both goodman and tempstar have issues with their heat exchangers. Goodman units have flimsy clamps that attach the heat exchanger to the outlets of the burner box. In my opinion, over time these...
  30. Replies
    7
    Views
    944

    My serial numbers dont fall in that range that is...

    My serial numbers dont fall in that range that is posted, Im wondering if the rating plates are changed for distrubution in Canada (Im from Toronto). Going to contact tec support tomorrow. Thanks...
  31. Thread: Chinese ULT

    by fd3687
    Replies
    29
    Views
    3,123

    No Im looking for info on the Ultra Low...

    No Im looking for info on the Ultra Low Temperature freezers, -86 degrees C.
  32. Replies
    11
    Views
    2,459

    Not worth it

    I sell the lennox xc21, and unless you have really bad humidiy where you live (which I think you dont) take a look at the XC15, about half the price, quietest unit on the market and it is extremly...
  33. Replies
    7
    Views
    944

    Silkysean, what do you mean by a mixup between...

    Silkysean, what do you mean by a mixup between gas and lp. The valves and burners weren't compatible? ie lp valves with ng burners?
  34. Thread: Chinese ULT

    by fd3687
    Replies
    29
    Views
    3,123

    Chinese ULT

    Has anyone serviced or installed either Haier or ZKMeiling ULT's.
  35. Replies
    31
    Views
    13,327

    Both manufactures make junk furnaces, stay away. ...

    Both manufactures make junk furnaces, stay away. Lennox, trane or carrier are good choices.
  36. Replies
    11
    Views
    1,506

    Installation is key. Safe bet with quality;...

    Installation is key. Safe bet with quality; lennox, trane, carrier. Go for the extended warranty. I know the lennox signature series offers 10 parts warranty, and they have the quietest units on...
  37. Replies
    16
    Views
    3,965

    No to quietside

    Our company use to install quietside boiler, oil, gas and propane, nothing but problems and really hard to get parts. Stay away!

    Have you thought about going with propane, more options; cooktop,...
  38. Replies
    7
    Views
    944

    Weil-McLain Ultra issues

    I'm a HVAC contractor, just wondering if anyone has had any problmes with the Weil-McLain Ultra boilers. I've installed two of these unit in one home, both model ULTRA 230. They're propane and I have...
  39. Replies
    1
    Views
    700

    Quietside QVM8 Problems!

    Hi, I'm working on a queitside QVM8-140-lp combo boiler. The chief complaint was no domestic hot water. I replaced the domestic automatic fill valve and that seemed to solve the problem. However I...
  40. Replies
    4
    Views
    713

    Pos

    I know I think they're a POS! The QVM9's are ok, but the 8 are junk!
  41. Replies
    4
    Views
    713

    Quietside problems

    Hi, I'm working on a queitside QVM8-140-lp combo boiler. The chief complaint was no domestic hot water. I replaced the domestic automatic fill valve and that seemed to solve the problem. However I...
Results 1 to 41 of 49
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event