Search:
Type: Posts; User: BanditACtech
Search: Search took 0.00 seconds.
-
12-05-2011, 10:46 PM
- Replies
- 5
- Views
- 583
Thanks i will see if they have it at our local...
Thanks
i will see if they have it at our local supply house, other wise i will order some.
that looks great -
12-05-2011, 10:41 PM
Thread: Coil combs
by BanditACtech- Replies
- 3
- Views
- 313
:LOL:LOL I was the helper not to long...
:LOL:LOL
I was the helper not to long ago......:cheers: -
12-04-2011, 10:45 PM
Thread: RTU insulation
by BanditACtech- Replies
- 5
- Views
- 536
Something that I like to do is ask the installers...
Something that I like to do is ask the installers to hand over their leftover “gum tape” , and I use it to apply it around the perimeter of each of the panels that I always see falling off. If you...
-
12-04-2011, 10:38 PM
Thread: plugged up heat exchanger
by BanditACtech- Replies
- 18
- Views
- 1,245
As musch trouble an time its causing, you might...
As musch trouble an time its causing, you might as well install a new one. may it rest in peace
-
12-04-2011, 10:32 PM
Thread: Sometimes I walk away
by BanditACtech- Replies
- 8
- Views
- 770
LOL sometimes thats all you can do
LOL sometimes thats all you can do
-
12-04-2011, 10:24 PM
Thread: Coil combs
by BanditACtech- Replies
- 3
- Views
- 313
Coil combs
Are there any good fin combs that really work?
I have one of the blue bicycle handle ones and it does pretty good. Just wondering if there’s something better.
:cheers::whistle:
Just trying to... -
12-04-2011, 10:21 PM
Thread: Clogged heat exchanger
by BanditACtech- Replies
- 5
- Views
- 666
No i dont have a combustion analyzer, but I will...
No i dont have a combustion analyzer, but I will check the heat exchanger and try the vacum thing when i go back, for repairs on other issues wiyh the unit.
Thank s for replying -
12-04-2011, 09:53 PM
Thread: Coil combs
by BanditACtech- Replies
- 8
- Views
- 623
Coil combs
Are there any good fin combs that really work?
I have one of the blue bicycle handle ones and it does pretty good. Just wondering if there’s something better. -
12-04-2011, 09:45 PM
Thread: Clogged heat exchanger
by BanditACtech- Replies
- 5
- Views
- 666
Clogged heat exchanger
I’m working on a Lennox LGA series 10 ton RTU. When performing the routine maintenance I found a wasp nest getting blown out through the exhaust vent. I removed the exhaust screen to allow the wasp...
-
12-04-2011, 07:05 PM
Thread: Carlyle Compressors
by BanditACtech- Replies
- 3
- Views
- 358
WOOOOOOHOO! Lots of info. Talk about been taken...
WOOOOOOHOO! Lots of info. Talk about been taken out of the dark! thanks, I really apreteiate it.
Just trying to follow that saying……….. “Always leave it better than you found it” -
12-04-2011, 06:43 PM
Thread: Carlyle Compressors
by BanditACtech- Replies
- 3
- Views
- 358
Carlyle Compressors
Hey Guys
I’m a fairly new tech (1 year Exp) looking for tips.
I have been trying to do some research online but can’t really find any good info to educate myself on Carlyle compressors. I have... -
12-04-2011, 06:31 PM
- Replies
- 5
- Views
- 583
Coil cleaning on Package units located in T-Bar ceiling
Hey Guys
I’m a fairly new tech (1 year Exp) looking for tips.
On one of my routs theirs a couple of multi floor level shopping malls. Most of them contain water source heap pumps in the T- Bar... -
12-04-2011, 01:21 PM
Thread: VAV boxes
by BanditACtech- Replies
- 6
- Views
- 560
After so many other techs there is no owner’s...
After so many other techs there is no owner’s manual in or around the box or around the T- Bar. No schematic, well one of them still had the schematic on the control but it’s not legible.
The only... -
12-04-2011, 02:24 AM
Thread: VAV boxes
by BanditACtech- Replies
- 6
- Views
- 560
one of the things i did not have time to find out...
one of the things i did not have time to find out
sorry that was a type O -
12-04-2011, 02:22 AM
Thread: VAV boxes
by BanditACtech- Replies
- 6
- Views
- 560
VAV systems
I spent some time on the site doing some recon if you will……. And so far I understood that at this store the VAV boxes are fed from a T-stat in the office and the T-stat are receiving temp readings...
-
12-04-2011, 01:44 AM
Thread: Coil Cleaning
by BanditACtech- Replies
- 20
- Views
- 1,386
I get good results when I 1st give it a quick...
I get good results when I 1st give it a quick wash with water to blow surface dirt away and then apply coil cleaner.
I think that low pressure washing from the inside out gets best results. If you... -
12-04-2011, 01:31 AM
Thread: VAV boxes
by BanditACtech- Replies
- 6
- Views
- 560
VAV boxes
Hey guys
I have just been given an opportunity to troubleshoot some VAV system for some Shopping mall, but I have no idea how to find some info to educate myself on these systems, so I’m looking...
Results 1 to 17 of 17