  1. Replies
    2
    Views
    282

    Jace access through Comcast Modem

    A customer recently had a Comcast modem installed at one of our sites. I cannot seem to get the bugger to communicate with the Jace. Does anyone have a cheat sheet or can instruct me as to getting...
  2. Replies
    10
    Views
    555

    Jace Remote access without a static IP

    I have a customer whom is getting a static IP. At this time the communication is lost remotely to the device. Can anyone tell me how to set up another temporary non static IP using the :81?

    TY
  3. Replies
    1
    Views
    202

    Jace remote communication loss

    Has anyone had any remote access drops on any Jace 3.6 ? I have two sites that are doing the same thing with different service providers. One is Comcast and the other is Verizon. I have checked both...
  4. Replies
    5
    Views
    980

    DuffyHVAC are you still looking for this...

    DuffyHVAC

    are you still looking for this device?
  5. Replies
    5
    Views
    980

    Facilitator

    I still have the device and the operators manual. Do you have the Johnson tools to access and reprogram? Because I do not have.
  6. Replies
    15
    Views
    2,893

    Trane units will run the economizer-If the...

    Trane units will run the economizer-If the economizer does not satisfy the supply air temperature in about 5-10 minutes, it WILL bring on a stage of cooling to try to satisfy the supply temperature...
  7. Replies
    28
    Views
    2,470

    Trane units will bring on the mechanical cooling...

    Trane units will bring on the mechanical cooling if the economizer does not make the supply temperature (55*F) in a certain amount of time. They usually run only the first stage with the economizer....
  8. Is this Voyager a VAV? They can take up to 15...

    Is this Voyager a VAV? They can take up to 15 minutes before a heat is initiated via test mode or a call from the controlling devices. If its an older model, they have cube relay(s) that I have seen...
  9. Replies
    6
    Views
    2,007

    There are 8 radiant loops coming from the supply...

    There are 8 radiant loops coming from the supply and return of the boiler. Each have their own pump and mixing valve. The boiler has its own pump and mixing device internal of the boiler. The boiler...
  10. Replies
    6
    Views
    2,007

    Primary

    Primary
  11. Replies
    6
    Views
    2,007

    Radiant heat boiler piping question

    I walked into a small nighmare. I went on a service call to deal with some noise issues with radiant floor heat. I have a Burnham Reliant boiler that maintains 160* at the boiler. The loop piping is...
  12. Replies
    14
    Views
    2,482

    Service tool

    It may not help you at the moment with a changed password, but you can purchase a Carrier Service tool and access anything you need to via the Carrier network or the connector on the front of the...
  13. I haven't been on a Tracker in some time. Did...

    I haven't been on a Tracker in some time. Did they give you the operating software for a PC?

    When you have had enough, you can see if they have the reliatel board in them that accept a...
  14. Replies
    1
    Views
    519

    Bacnet speed question

    I have an FX-40 running bacnet at a facility. I know this device has limited capabilities, but an engineer has asked if the Baud rate can be ramped up from the current 38+ to 76+ to improve...
  15. Replies
    36
    Views
    7,314

    I hope I didn't ruin your expectations. Unless...

    I hope I didn't ruin your expectations. Unless you work for the government, you will have to work. Sorry for the pain and anguish. It is my beleif that you will find good and not the Evil.:cheers:
  16. Replies
    36
    Views
    7,314

    You can lead a human to knowledge, but you can't...

    You can lead a human to knowledge, but you can't make him think. There are no short cuts in life. Stop leaks do not work. When the oil is trashed and the lubrication fails, the next guy will be...
  17. Replies
    40
    Views
    5,044

    I have used the "Johnson"/Yokagawa for years....

    I have used the "Johnson"/Yokagawa for years. This is the best leak detection device I have ever used or seen in 32 years in the business. Do not look any further, look to find where you can get one....
  18. I hope the water heat is constant. Some people...

    I hope the water heat is constant. Some people like to shut that heat off when the temp. gets warm outside. Just sayin Yo. Can really mess things up and then they will blame the controls tech.
  19. Replies
    22
    Views
    3,227

    Most Liebert or any other computer room...

    Most Liebert or any other computer room condensers are rather thick. It takes a "trained eye" to "really clean it" when it's "way bad dude". I never even trust my own work, therefore I alway double...
  20. Replies
    18
    Views
    2,153

    I feel for you. Always start with the easy stuff....

    I feel for you. Always start with the easy stuff. Power Supply-OK. Control voltage-OK. Reboot-OK. Alway check the stupid plug connectors on a Trane. On the small Voyagers, there is always one near...
  21. Thread: Megging!

    by Beacon Tech
    Replies
    26
    Views
    2,410

    Never had a problem megging anything low or high...

    Never had a problem megging anything low or high pressure myself in 32 years. I don't work on many systems that run the real low pressure refrigerants either (like R-11). Any system without crankcase...
  22. Replies
    14
    Views
    3,125

    Smoke detectors are ALWAYS a life safety device...

    Smoke detectors are ALWAYS a life safety device and should ALWAYS break the control power to any device immediatly including any time delays. Some manufactures have built in control logic for shut...
  23. Replies
    2
    Views
    657

    NVO Space Temp Not updating

    I have a lon building with a newer Tridium (3 Years old tops) and some Honeywell Excel 10 Smart VAV controls. I have one thats not smart anymore. The space temp will not update the current...
  24. Residential Refrigerator/Freezer Question

    I'm going to have to replace my refrigerator/Freezer soon at my home. Since I work in the Commercial/Industrial sector, I do not know much about which Brands are good or bad. I also heard they don't...
  25. Would you happen to know the part #? I'll check...

    Would you happen to know the part #? I'll check the part #'s on the ones I have.