Search:

Type: Posts; User: CoolWine

Page 1 of 20 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    7
    Views
    519

    Most likely because they were able to go to 134...

    Most likely because they were able to go to 134 from 12 using the same compressors.
  2. Replies
    26
    Views
    880

    I'd be much more concerned with the disconnect. ...

    I'd be much more concerned with the disconnect.

    How about making a sheet metal ring to raise the height 12" -18". It wouldn't take more than some metal and screws, though I would add a edge guard...
  3. One of the few harbor freight purchases I'm happy...

    One of the few harbor freight purchases I'm happy with.
    http://www.harborfreight.com/2-piece-rubber-strap-wrench-set-94119.html#.UzJN0M7AvSg
  4. Baller project. We've done a few projects with...

    Baller project. We've done a few projects with mechanicals like that, one crazy one that you thought you were in a sub or military ship the way everything was laid out and labeled.

    We have one...
  5. Replies
    13
    Views
    850

    http://store.snapon.com/ free shipping to. ...

    http://store.snapon.com/

    free shipping to.

    This ratcheting screwdriver is one of my all time favorite tools...
  6. Replies
    22
    Views
    1,001

    I have to agree, those old mechanical pressure...

    I have to agree, those old mechanical pressure controls with cap tubes are notorious leakers. The encapsulated controls have been super reliable for us.
  7. Replies
    22
    Views
    1,001

    I took a quick peek, didn't see anything. We've...

    I took a quick peek, didn't see anything. We've used the JC 350 series for something similar but $$$.
  8. Replies
    11
    Views
    771

    Rain please.

    Rain please.
  9. Replies
    14
    Views
    1,010

    Kind of sorta...I reach for these more often than...

    Kind of sorta...I reach for these more often than a traditional adjustable.

    http://www.knipex.com/index.php?id=1216&L=1&page=art_detail&parentID=1368&groupID=1500&artID=2939
  10. cost and availability.

    cost and availability.
  11. Replies
    12
    Views
    640

    Not unless there is a leak at this temperate...

    Not unless there is a leak at this temperate range. SST=45° (40psi)

    Let's see how 290 plays out. :det:


    Isn't it still the choice for most domestic products sold today?


    Why...It seems...
  12. Replies
    14
    Views
    898

    I've used those and think they SUCK. How many...

    I've used those and think they SUCK.

    How many holes do you have to cut? These work just fine ;)...
  13. Replies
    12
    Views
    640

    Both run POE, the 134 will never run in a vacuum....

    Both run POE, the 134 will never run in a vacuum. 134 has no glide.
    Why do you prefer 404 over 134?
  14. Replies
    12
    Views
    640

    I was under the impression that 134 has the...

    I was under the impression that 134 has the lowest equipment cost and 404 higher, not that the difference is significant.

    My "math" may be off base but if we look at 1/4HP Copeland units.
    134...
  15. Replies
    7
    Views
    431

    I believe you can not run 134 in a 22 compressor...

    I believe you can not run 134 in a 22 compressor due to higher compression ratio's. I also believe that at the same HP that 134 would have a much lower capacity. I'm sure Icemeister or another...
  16. Replies
    12
    Views
    640

    134 vs 404 in fractional systems

    If you were setting up new equipment (medium temp, fractional HP) what refrigerant would you choose and why?
  17. Replies
    23
    Views
    1,272

    I've had a thermostat cause the same thing.

    I've had a thermostat cause the same thing.
  18. Replies
    13
    Views
    1,974

    WOW. Low bidder gets the job again.

    WOW. Low bidder gets the job again.
  19. Replies
    75
    Views
    7,864

    Hopefully it won't do this to you...

    Hopefully it won't do this to you http://en.wikipedia.org/wiki/Radium_Girls
  20. Replies
    31
    Views
    1,938

    no free s/h but I've had great service and...

    no free s/h but I've had great service and pricing from hvacr tools. http://hvacr-tools.com/
  21. Replies
    28
    Views
    1,924

    Refacing tool for flare fittings.

    Refacing tool for flare fittings.
  22. Looks like the consensus is for leaving them in...

    Looks like the consensus is for leaving them in the truck, which is what I will continue to do. :putergreet:
  23. Cold Weather Care of Meters, Digi Manifolds & Electrical Gear

    Do you guys bring your tools in at night in this cold weather?

    I'll admit I've been leaving them in the truck and haven't had issues :couchhide:
  24. Thread: wine cellar

    by CoolWine
    Replies
    43
    Views
    2,341

    Not that it matters now but it strikes me as bad...

    Not that it matters now but it strikes me as bad practice to leave a system in a vacuum, especially a system that runs POE.

    Explain to me how a CCH would overload a circuit and a light bulb...
  25. Thread: wine cellar

    by CoolWine
    Replies
    43
    Views
    2,341

    single pain? frameless? Hope that evap isn't...

    single pain? frameless? Hope that evap isn't blowing on that glass. What would typical RH be in the summer in that dining room.