Search:

Type: Posts; User: d_griff

Page 1 of 20 1 2 3 4

Search: Search took 0.04 seconds.

  1. Thread: Thrush prv

    by d_griff
    Replies
    0
    Views
    150

    Thrush prv

    Hello everyone,
    I am looking for some info on a thrush valve. The info says Model G 72e #40 and that's all I have. I can't pull any info through a search. Any help would be appreciated. Thanks!
  2. Replies
    6
    Views
    636

    Thanks for the info!

    Thanks for the info!
  3. Replies
    6
    Views
    636

    Thanks. I actually have some paperwork, I...

    Thanks. I actually have some paperwork, I actually took a class 8 years ago when I worked on this, just forgot a lot and need to get the wheels going haha. Does TSR01W sound like a number on the...
  4. Replies
    6
    Views
    636

    Carrier VVT help

    I have a Carrier 33CS system, I'm trying to get some info on, its been a few years since. I have SE 11 fault (high/low temp exceeded) on my master stats. When I push the duct temp on my bypass it...
  5. Replies
    2
    Views
    582

    Yes, in my opinion. It is very hard to find a...

    Yes, in my opinion. It is very hard to find a commercial company that will train their techs. So as this field appears to be moving more toward everything being propitiatory, It is harder and harder...
  6. Replies
    1
    Views
    1,276

    YORK P2MP MANUAL

    Hellp again,
    I am trying to locate the install manual for a York furnace. M# P2MPD14N08001B S# EACM050178
    Any help is appreciated! Thanks!
  7. Replies
    3
    Views
    473

    Perfect, thanks!

    Perfect, thanks!
  8. Replies
    3
    Views
    473

    POWER VENTING YORK FURNACE?

    Hello again everyone,
    I have a customer with a situation, they had an addition put on their house, Long story short the contractor never extended or insulated the chimney, So moisture rotted it...
  9. Replies
    5
    Views
    1,533

    Wow, Thanks!

    Wow, Thanks!
  10. Replies
    5
    Views
    1,533

    Yes I was thining of making my own, but I was...

    Yes I was thining of making my own, but I was trying for the easy way out haha
  11. Replies
    5
    Views
    1,533

    COMMERCIAL SERVICE INVOICE TEMPLATE

    Anyone know of a good hvac commercial service invoice template? all of the invoices I can find online tend to be geared more towards the residential end of the business if that makes any sense.
  12. Replies
    5
    Views
    1,270

    Explain that again please???

    Explain that again please???
  13. Replies
    41
    Views
    3,547

    I use R11 on a regular basis to flush linesets....

    I use R11 on a regular basis to flush linesets. It can get expensive, But the manufacterer usually recommends it. We just raplaced two 25 ton Liebert systems in a data room, And the linesets were not...
  14. Replies
    6
    Views
    896

    A Lock out relay is normally just a relay, it is...

    A Lock out relay is normally just a relay, it is usually how it is wired that makes it a "lock out" relay.
  15. Replies
    5
    Views
    1,270

    Okay I will guess at it, Are you reffering to...

    Okay I will guess at it, Are you reffering to having a heat pump installed? The my short answer would be yes, Because when it goes into defrost it will be in A/C mode in the winter, and that is...
  16. Replies
    5
    Views
    1,270

    I dont know, do you? you need to be more...

    I dont know, do you?
    you need to be more specific with your question
  17. Thread: Just curious

    by d_griff
    Replies
    25
    Views
    1,421

    My company is so bad, We dont even do data entry...

    My company is so bad, We dont even do data entry :eek:
    When I do a PM, I list all of the filters and belts that I use on the invoice. And when I get dispatched for that Pm again at a later date, I...
  18. Thread: Just curious

    by d_griff
    Replies
    25
    Views
    1,421

    No, You usually get just a name an address, And...

    No, You usually get just a name an address, And scope of work, for example, you have a furnace check at John Doe's residence 111 street road. Unless they have laptops in their trucks, Which few...
  19. Replies
    42
    Views
    2,104

    Maybe you guys are misreading my post, Or i wrote...

    Maybe you guys are misreading my post, Or i wrote it wrong :grin2: I was not saying I do not feel the aches and pains, i was saying I know that's what you guys would say because I am what some of you...
  20. Replies
    42
    Views
    2,104

    32 :grin2: Been working on these roofs my entire...

    32 :grin2: Been working on these roofs my entire life now and been doing hvac for 13 years:eek: I know I know.... I dont know what it is like to have aches and pains blah blah :bump: But trust me I...
  21. Replies
    42
    Views
    2,104

    I would like to invest in a pair of coveralls for...

    I would like to invest in a pair of coveralls for that weather, Once your pants get wet it can make it a tough day, Especially when your long johns are wet too, then you get in trouble. Are there any...
  22. Replies
    42
    Views
    2,104

    I will stand in snow up to my knees with my plain...

    I will stand in snow up to my knees with my plain socks, Wolverines, and basically a sweatshirt over a few layers, plowing through the snow as said before, to work on a small POS RTU that should have...
  23. Replies
    42
    Views
    2,104

    Agree!! If the sweatshirt comes below your...

    Agree!! If the sweatshirt comes below your behind, and you are lucky enough to have it zipper up and cover your neck, You will never need the over priced stiff jacket IMHO
  24. Replies
    42
    Views
    2,104

    I have found that over doing it is what makes it...

    I have found that over doing it is what makes it worse, There's really no reason to wear anything other then a regular sock that comes up towards the knee, And a boot with at least 800 grams...
  25. Replies
    27
    Views
    3,067

    Where can I find info on this? I do not like the...

    Where can I find info on this? I do not like the current Veto's they look sort of oversized and bulky, I have a Husky now, it is terrible, I would really like to find a good bag also, I go through...
  26. Replies
    42
    Views
    2,104

    Agree 100%. clearance rack clearance rack! except...

    Agree 100%. clearance rack clearance rack! except the boots of course believe me i tried, you cant use cheap boots... I always buy my winter clothes in the spring, I have a few of the flannel lined...
  27. Replies
    42
    Views
    2,104

    :grin2:I have a simliar one but it is Dickies, It...

    :grin2:I have a simliar one but it is Dickies, It looks almost identical, It does the job if I am layered right, but I never cared for how stiff them coats feel, And how they make it hard to move,...
  28. Replies
    41
    Views
    3,547

    Some of the older leak detectors could not...

    Some of the older leak detectors could not "sniff" the HFC 410-A. So you would have had to put a trace of R-22 in if your leak detector can only detect HFCF to find a leak. Just get the proper tool...
  29. Replies
    7
    Views
    667

    A short to ground will become the common (ground)

    A short to ground will become the common (ground)
  30. Replies
    7
    Views
    667

    Wire the fuse on the primary side, Always. If a...

    Wire the fuse on the primary side, Always. If a component is shorted the common side may never even see the high amps before something smokes. You should have a very low amp draw on a 24 volt...
  31. Who was recording the temps on paper and taking...

    Who was recording the temps on paper and taking that much time? a student? :grin2::bump:. there's no reason why you cant calculate SH and SB with a standard manifold and probe in the same amount of...
  32. I personally believe being a good tech has...

    I personally believe being a good tech has absolutely nothing to do with "willing to do things other techs wont". that may just mean your stupid.:grin2:
  33. We got a few of them down in center city Philly...

    We got a few of them down in center city Philly where HVAC wasnt aruond when they built these houses, So they smacked a package unit on a pitched shingled roof. We have a few on flat roofs also....
  34. Well said, And very true:cheers:

    Well said, And very true:cheers:
  35. Thread: Pilot Issues??

    by d_griff
    Replies
    4
    Views
    811

    If you have a regulator on the line coming from...

    If you have a regulator on the line coming from the tank, See if the outlet of the regulator vent is clogged with insect debris, Sometimes a spider can get in there and it will cause an erratic gas...
  36. Replies
    7
    Views
    667

    Start by taking the meter off of volts, get the...

    Start by taking the meter off of volts, get the amp draw of the low voltage circuit while your running it, And put it on Ohms, Find something shorted to ground or shorted from primary and secondary...
  37. Replies
    13
    Views
    2,369

    I let the timer do mine personally, It is set...

    I let the timer do mine personally, It is set from dip switches on the circuit board (goodman 95%) If the furnace fires for 8 minutes and cannot reach setpoint then the second stage comes in, Mainly...
  38. Replies
    8
    Views
    815

    Capf24csca?

    Capf24csca?
  39. Replies
    11
    Views
    1,331

    Sometimes, there is no rack, And you just have to...

    Sometimes, there is no rack, And you just have to fit it in behind the blower door against the opening. you can measure it that way, Or call a local guy and it sucks, But pay them to fab you up a...
  40. Thread: gas furnace

    by d_griff
    Replies
    10
    Views
    432

    Change the filter, If it is still happening there...

    Change the filter, If it is still happening there is a problem, Call a pro:callpro:
  41. Replies
    11
    Views
    1,331

    Well, Sometimes it is in the furnace behind the...

    Well, Sometimes it is in the furnace behind the blower door, And you have to take the door off to access it. Sometimes it may have a filter box in the return somewhere, And sometimes they may have...
  42. Replies
    11
    Views
    1,331

    Are you reffering to the oil line filter, Or the...

    Are you reffering to the oil line filter, Or the air filter? Is it forced air with duct work or is it radiator?
  43. Replies
    25
    Views
    3,460

    some new tankless water heaters come with an...

    some new tankless water heaters come with an electronic control that will not allow you to exceed 120 hot water, For example, If you buy a Rannai you would have to pay extra to upgrade to a control...
  44. Not in my area it isnt, they are no longer...

    Not in my area it isnt, they are no longer required.
  45. Replies
    25
    Views
    3,460

    I also agree with Vegas, 130 would be okay if the...

    I also agree with Vegas, 130 would be okay if the HP is also running as a supplement, But if you want to shut the HP off and use the hot water feature only on an extremely cold day, Depending on...
  46. Replies
    25
    Views
    3,460

    Yuo could just return the exit water to the tank,...

    Yuo could just return the exit water to the tank, You would have a storage tank and a pump dedicated for the coil, the pump could just recycle the water from it all day, Or shut off on a call with a...
  47. Replies
    25
    Views
    3,460

    You dont already have a boiler? Go with electric...

    You dont already have a boiler? Go with electric :cheers:
  48. With a lot of the newer furnaces you have to use...

    With a lot of the newer furnaces you have to use a bigger size exhaust if you use outside air intake as well, Example, you can use a 2 1/2" exhause pipe if you are pulling your combustion air from...
  49. You would need to know gas pressure for us to...

    You would need to know gas pressure for us to help you, that is the first thing I would check if i only light off one burner out of several. I would let the installer handle it, Since you are on here...
  50. Replies
    2
    Views
    1,042

    It happens sometimes with relays and coils, I...

    It happens sometimes with relays and coils, I wouldnt be to concerned with it as long as it is working properly in my opinion.
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event