  1. Replies
    0
    Views
    254

    2 X 2 t-bar diffuser with damper

    I'll looking for some help to find a company that makes a 2 x 2 t-bar diffuser w/ a damper already installed in the diffuser. I know they make retro kits. But since this a new install, I would rather...
  2. Replies
    5
    Views
    747

    Just a quick update. The HPS was no closed all...

    Just a quick update. The HPS was no closed all the way, even though it passed a continuity test. Thanks for the help.
  3. Replies
    5
    Views
    747

    York RTU no cooling

    I have a York RTU D3NZ036 unit that the customer complained of no cooling. The unit has 24v to the Y terminal on the control board, but the 24v contactor doesn't engage, and there is not 24v at the...
  4. cfe, anymore issues with this unit? I have the...

    cfe, anymore issues with this unit? I have the exact same codes on a 4 ton ZJ series York unit. I changed the filters and checked voltages. Ran the unit for two hours no issues. If you have any other...
  5. Replies
    2
    Views
    594

    Thanks for the help.

    Thanks for the help.
  6. Replies
    2
    Views
    594

    York ZJ series wiring diagram

    I'm looking for a wiring diagram for a York ZJ series RTU. The model number is ZJ048N10A1AAA1. The one on the inside of the panel is too faded to read. Thanks for any and all help.
  7. Replies
    19
    Views
    2,718

    Not trying to be smart. But a r-22 unit shouldn't...

    Not trying to be smart. But a r-22 unit shouldn't have anything else used in it. If a system needs r-22 on a regular basis, its probably time to replace it with a R-410a system.
  8. Replies
    0
    Views
    333

    Tork draft inducer motor

    Does anyone have a link to check the compatibility of York draft inducer motors. I have a OEM motor Fasco part number 71211958, and I am trying to check if a York S1-02424115018 is interchangeable...
  9. Replies
    21
    Views
    2,562

    Heard of it, but never ran into it. I thought it...

    Heard of it, but never ran into it. I thought it was more prevalent in the humid south, and more commonly associated with high eff. equipment. The unit is about 20 years old, so replacing just the...
  10. Replies
    21
    Views
    2,562

    The mouse makes sense. I'll run a camera through...

    The mouse makes sense. I'll run a camera through the ductwork to check it out.
  11. Replies
    21
    Views
    2,562

    One of my first thoughts also. But the drain line...

    One of my first thoughts also. But the drain line exits the building through the wall and terminates directly outside., so there is no connection to any type of sewer line.
  12. Replies
    21
    Views
    2,562

    No, just standard ductboard. The heat strip was...

    No, just standard ductboard. The heat strip was visually inspected and looks and operates normally. The customer says "sewer" smell, I have been unable to smell it on two previous visits, however, an...
  13. Replies
    21
    Views
    2,562

    "sewer" smell from the ductwork

    I have a customer complaining of a "sewer" smell coming from the ductwork. The smell only seems to be noticeable when the aux heat strip is on. The air handler is an older Trane unit with 10kw...
  14. Replies
    8
    Views
    968

    Failed compressors

    Had two different units with failed compressors in the past two weeks. One was Carries 48SS series RTU and the other was a Trane HP split system. Based upon the tests I ran the 48SS seemed to be a...
  15. Replies
    5
    Views
    826

    Thanks

    Thanks
  16. Replies
    5
    Views
    826

    Carrier 48SS cap size

    Does anyone have information on cap sizes for a Carrier 48SS030080301 RTU. The old one is too faded to read. Thanks.
  17. The local supply house, APR Supply, told me last...

    The local supply house, APR Supply, told me last week that dry R-22 condensers are available.
  18. Freeing the compressor by hitting with a hammer...

    Freeing the compressor by hitting with a hammer is a temporary fit. Almost always its going to stop again, plan on replacing it on your schedule, not on the the compressor's. (probably a weekend)...
  19. Replies
    34
    Views
    3,500

    Evacuated to 28 in of vacuum, and 275 microns...

    Evacuated to 28 in of vacuum, and 275 microns ,and held 28 in for two hours so no leaks, of course also changed the drier.
  20. Replies
    34
    Views
    3,500

    Compressor operating in a vacuum

    About a month ago I got a call from a tenant with a Trane unit TWL736A100AO stating that the unit wasn't cooling. I usually do my own service work but was out of town. I called the service company I...
  21. Thread: Inspectors

    by juststartin
    Replies
    5
    Views
    525

    Inspectors

    Just remodeled a 1200 square foot commercial space for a tenant and installed a Lennox split system heat pump. So the fire inspector is there to give the Occupancy Permit, he looks at the outside...
  22. Replies
    29
    Views
    1,666

    The Volt may get 230 MPG, but the design is such...

    The Volt may get 230 MPG, but the design is such that the bulk of your use will be done by charging the batteries with AC current from your home. Since the electricity in the NE is mostly generated...
  23. Replies
    4
    Views
    512

    Based upon the York nomenclature I could find...

    Based upon the York nomenclature I could find that model has 76,000 BTUs of cooling. I don't know of the date of manufacture, although since its a 4 model its a 4th generation of the series, so it...
  24. Replies
    4
    Views
    698

    Thanks.

    Thanks.
  25. Replies
    4
    Views
    698

    Single phase 208/230V

    Single phase 208/230V
  26. Replies
    4
    Views
    698

    York RTU Suggestions

    I'm looking for suggestions on a new RTU for a 1200 sq foot commercial space. Are there any York gas/ electric RTUs anyone can recommend. I would like to stay with York because we already have four...
  27. Replies
    8
    Views
    1,887

    I have one about six months, but haven't used it...

    I have one about six months, but haven't used it for anything except natural gas pressures. It works very well with either the HS36 meter or the data logger. From what the manual states reading wc...
  28. Replies
    40
    Views
    3,707

    I have always said Ruud, which rhymes with mud....

    I have always said Ruud, which rhymes with mud. But my wife thinks I talk funny anyway.:D
  29. Replies
    21
    Views
    2,528

    The largest HVAC contractor in our area has a...

    The largest HVAC contractor in our area has a trailer mounted unit and I go past his shop everyday, but the unit is always parked in the lot. So I don't think may people use the service. That being...
  30. Talking about stupid people, I have some...

    Talking about stupid people, I have some residential and commercial rentals. We have a strip mall unit going vacant next month. So the ad states, strip mall location, 1250 sq feet ,available 3/1/09,...
  31. Please send me a copy. Thanks.

    Please send me a copy. Thanks.
  32. Replies
    29
    Views
    1,731

    I agree with yellowirenut, don't get anything...

    I agree with yellowirenut, don't get anything until you see what the employer will provide. I am in a similar job, the apartment owner provided gauges, evac pump, etc. I had to provide wire cutters,...
  33. Replies
    50
    Views
    2,865

    No I don't think fused disconnects are used very...

    No I don't think fused disconnects are used very much. In my LIMITED experience, it seems any installation in the past 3-5 years use a basic disconnect, and most older than that use a fused one. I'm...
  34. Replies
    45
    Views
    2,745

    That's why I love this site. I learned as much in...

    That's why I love this site. I learned as much in this thread as I learned in an entire day of class!!:)
  35. Replies
    17
    Views
    4,568

    About 80 miles northeast of Harrisburg, and about...

    About 80 miles northeast of Harrisburg, and about 90 miles north of Philly
  36. Replies
    17
    Views
    4,568

    Iraqveteran, I know I'm a few days late, but...

    Iraqveteran,

    I know I'm a few days late, but thank you for your service.
  37. Replies
    17
    Views
    4,568

    Point well taken:)

    Point well taken:)
  38. Replies
    17
    Views
    4,568

    Airmechanical, I guess I should have said a...

    Airmechanical, I guess I should have said a "good" electrician wouldn't think about mixing up the colors. I don't know about TN, but in PA the electrical inspecter will make you tear it out if it's...
  39. Replies
    17
    Views
    4,568

    low voltage wiring colors

    Since I'm just learning this profession, this may be a silly question. But why doesn't all techs use the same colors on the 24v thermostat wire to do the same function? I know not all units have two...
  40. Replies
    25
    Views
    3,561

    Thanks for all the great replies. Again it's been...

    Thanks for all the great replies. Again it's been proven you can't believe everything you read. Thanks again for all the help.
  41. Replies
    25
    Views
    3,561

    brazing vs. soldering

    I am just starting to learn the trade, so please bear with me. On brazing lines vs. soldering, the instructor told me that ALL connections should be brazed using at least 15% silver, if not 45 %...