Search:
Type: Posts; User: brianbrb
Search: Search took 0.01 seconds.
-
10-01-2006, 02:54 PM
Thread: New Condenser (Goodman)
by brianbrb- Replies
- 36
- Views
- 6,621
goodman quality
My buisiness partner and i just recently returned from a trip to the goodman manufacturing plant, airfare, lodging meals, and a professionally guided fishing trip were included and all paid for by...
-
04-24-2006, 08:33 PM
Thread: pat on the back for the guys in install
by brianbrb- Replies
- 17
- Views
- 2,881
I agree with the last two posts, not a very good...
I agree with the last two posts, not a very good install at all.
-
04-23-2006, 06:21 PM
Thread: "One of a few" and it looks GOOD!
by brianbrb- Replies
- 23
- Views
- 3,545
anything to do with carrier whether it be bryant...
anything to do with carrier whether it be bryant or payne is not a good product, i have customers tell me they want anything but carrier in their home, that tells me alot about a product when a...
-
04-11-2006, 08:23 PM
Thread: "One of a few" and it looks GOOD!
by brianbrb- Replies
- 23
- Views
- 3,545
Just went to goodman 13 seer seminar last night...
Just went to goodman 13 seer seminar last night to see what they are all about, and from what i could see they will be giving everyone else some competition in the near future, not saying i will push...
-
04-11-2006, 08:04 PM
Thread: Pictures tell a thousand words........
by brianbrb- Replies
- 54
- Views
- 4,058
That goodman coil has a different style orrifice...
That goodman coil has a different style orrifice ( the thing in the plastic bag, it is used to meter the refrigerant to the coil) than a trane orrifice, or does the coil have a TX valve (thermal...
-
04-10-2006, 09:09 PM
Thread: ADP vs Carrier coil and warranty
by brianbrb- Replies
- 8
- Views
- 3,030
ADP is a good quality coil, have installed a few...
ADP is a good quality coil, have installed a few in the past, as far as warranty goes i'm not too sure as i only install them, but it's a quality product
-
04-01-2006, 08:19 PM
Thread: metal duct compared to duct board
by brianbrb- Replies
- 112
- Views
- 17,003
on call, how many ductboard systems have you...
on call, how many ductboard systems have you installed compared to metal systems, by the tone of your defensiveness it sound like you don't use metal at all, many postings on this site have dealt...
-
04-01-2006, 09:08 AM
Thread: Rusted vents & collapsing ducts
by brianbrb- Replies
- 18
- Views
- 1,406
as long as they are sized corectly and installed...
as long as they are sized corectly and installed properly there is nothing wrong with ceiling registers, don't know why you would go in the sidewall if you have a full attic to work in, seems like a...
-
03-18-2006, 09:04 PM
Thread: duct work question(s)
by brianbrb- Replies
- 46
- Views
- 3,209
Chillbilly, seems you and i are the only ones...
Chillbilly, seems you and i are the only ones that still use metal ducts in this thread, i don't know if that means no one knows how to size and install metal or what but it is very obvious in my own...
-
03-15-2006, 06:05 AM
Thread: duct work question(s)
by brianbrb- Replies
- 46
- Views
- 3,209
Just what i figured, it's all about the sale, i...
Just what i figured, it's all about the sale, i would turn down a job if the customer wants duct board (politely of course) but with 15 years in buisness i have never had a customer request it, as...
-
03-13-2006, 06:30 AM
Thread: duct work question(s)
by brianbrb- Replies
- 46
- Views
- 3,209
I can't believe this conversation is going on so...
I can't believe this conversation is going on so long, if you duct board guys want me to believe that you would pick duct board over metal if offered side by side both at a comparable cost i think...
-
03-09-2006, 08:13 PM
Thread: duct work question(s)
by brianbrb- Replies
- 46
- Views
- 3,209
duct board is junk no matter how you look at...
duct board is junk no matter how you look at it,any reasonable person would come to the conclusion that over the years of air moving at a fairly high cfm through it that it will break down and start...
-
03-08-2006, 07:10 PM
Thread: duct work question(s)
by brianbrb- Replies
- 46
- Views
- 3,209
duct board is no good if you ask me, it breaks...
duct board is no good if you ask me, it breaks down over time and you end up blowing fibreglass all over your house and many people end up with respratory problems, you can insulate metal ducts on...
-
why a filter drier, doesn't trane\american...
why a filter drier, doesn't trane\american standard come with one factory installed inside the condenser
-
03-01-2006, 04:45 PM
Thread: Line-Hide Lineset Cover System
by brianbrb- Replies
- 10
- Views
- 6,147
we use slimduct on all installs that are exposed,...
we use slimduct on all installs that are exposed, it looks professional and is easy to use, and the customers love it, gutters are old school and don'tlook all that great, the slimduct line of...
-
02-27-2006, 03:38 PM
Thread: Here's a cheap spec house
by brianbrb- Replies
- 23
- Views
- 3,718
never said the question was about if it's code ,...
never said the question was about if it's code , just saying it is code where i do my work
-
02-26-2006, 04:51 PM
Thread: Here's a cheap spec house
by brianbrb- Replies
- 23
- Views
- 3,718
In Mass it's code to run them seperately, won't...
In Mass it's code to run them seperately, won't pass inspection if they are in the same conduit, and yes the inspectors do actually check it
-
02-23-2006, 09:24 AM
- Replies
- 11
- Views
- 1,108
Around here we call it a canadian cold trap and...
Around here we call it a canadian cold trap and it works fantastic, just like the previous posts site run it to floor level and double 90 it up and you will never have a draft unless equiptment is...
-
02-13-2006, 08:06 PM
Thread: Aprilaire 5000 upside down?
by brianbrb- Replies
- 6
- Views
- 707
Just put one in last week and as baldloonie said...
Just put one in last week and as baldloonie said only the nameplte flips over and the power pack stays the same, and yes the on \off switch is upside down but it doesn't affect the opperation of the...
-
02-08-2006, 09:08 PM
Thread: Laundry closet furnace/coil install.
by brianbrb- Replies
- 16
- Views
- 2,283
not trying to get anyone upset, just saying at my...
not trying to get anyone upset, just saying at my company we always change to b-vent for code reasons, and our own peice of mind
-
02-08-2006, 07:52 PM
Thread: 90 degree elbows and air flow
by brianbrb- Replies
- 35
- Views
- 2,159
That furnace is a 2 pipe unit, why did they add...
That furnace is a 2 pipe unit, why did they add combustion air for it????
-
02-08-2006, 06:39 PM
Thread: 90 degree elbows and air flow
by brianbrb- Replies
- 35
- Views
- 2,159
Your models blower has a 2,000 cfm capacity on...
Your models blower has a 2,000 cfm capacity on high speed , so since it is capable of moving 2,000 cfm you need return out of both sides, one side and bottom , or the bottom, even though you say your...
-
02-08-2006, 03:49 PM
Thread: Laundry closet furnace/coil install.
by brianbrb- Replies
- 16
- Views
- 2,283
Me too , when we remove a furnace and install...
Me too , when we remove a furnace and install new, we need to change the flue to all b-vent, plus in that kind of room i would put b-vent anyways
-
02-08-2006, 03:41 PM
Thread: 90 degree elbows and air flow
by brianbrb- Replies
- 35
- Views
- 2,159
I install rheems all the time and on a 120,000...
I install rheems all the time and on a 120,000 you definately need both sides , the bottom, or one side and the bottom for proper return air , and you say the noise isn't as bad with the 6" filter...
-
02-05-2006, 06:07 PM
- Replies
- 13
- Views
- 1,288
Here in Mass we are having trouble getting ten...
Here in Mass we are having trouble getting ten seer stuff also, just last week i bought the last ten 2.5ton condensers my american standard dealer had, just want to be prepared for those tight...
Results 1 to 25 of 45

