Search Results - HVAC-Talk: Heating, Air & Refrigeration Discussion

Search:

Type: Posts; User: hvacjack78

Page 1 of 3 1 2 3

Search: Search took 0.01 seconds.

  1. Replies
    24
    Views
    14,612

    go with lennox.go with a higher...

    go with lennox.go with a higher efficiency.compressors will be a scroll which are much quieter. go to the lennox website and check it out yourself you can check decibel readings etc.
  2. Replies
    1
    Views
    469

    if you don't maintain it the manufacturer won't...

    if you don't maintain it the manufacturer won't warranty it.if i don't change the oil in my new car same thing.if your condensate drain plugs up you can expect to pay for that(and a new carpet or...
  3. Replies
    30
    Views
    4,110

    if the compressor is bad that means it has...

    if the compressor is bad that means it has contaminated the system.just swap out the compressor and put a liquid and suction line drier in
  4. Replies
    9
    Views
    715

    i would assume you have a honeywell vision pro...

    i would assume you have a honeywell vision pro 8000?
  5. that's cool.thank you for the quick response.in...

    that's cool.thank you for the quick response.in this field it seems like if i ask ten different guys i get ten different answers.
  6. with a system that is 27 yrs. old there can be...

    with a system that is 27 yrs. old there can be numerous problems.you could have a dirty indoor/outdoor coil,blower wheel may have a lot of dirt on it,you may have unknowingly blocked a return by...
  7. from what i've read it's not very clear(to me at...

    from what i've read it's not very clear(to me at least.i need things spelled out).r-22 will not be made or imported for systems using r-22 after 2010 according to e.p.a. guideines.does this mean r-22...
  8. 27 yrs. old? is that a 2 SEER unit or a 1 SEER?

    27 yrs. old? is that a 2 SEER unit or a 1 SEER?
  9. Replies
    9
    Views
    715

    if you have a humidity control on your t-stat the...

    if you have a humidity control on your t-stat the system will run on occassion to "rip out" the humidity but, the system should not run in the off position
  10. Replies
    28
    Views
    4,855

    you took the words right out of my mouth.

    you took the words right out of my mouth.