Search:

Type: Posts; User: fd3687

Page 1 of 2 1 2

Search: Search took 0.00 seconds.

  1. Replies
    45
    Views
    37,807

    That's in the last 6 months.

    That's in the last 6 months.
  2. Replies
    45
    Views
    37,807

    They no longer carry Quietside.

    They no longer carry Quietside.
  3. Replies
    45
    Views
    37,807

    Check out their BBB rating @...

    Check out their BBB rating @ www.bbb.org/quietside
  4. Replies
    45
    Views
    37,807

    Never Again! Getting parts for these units are...

    Never Again! Getting parts for these units are like pulling teeth! Older water heaters didnt come with freezer protection, heat exchangers froze and cracked. Could build a better unit with Lego.
  5. Replies
    12
    Views
    644

    Party Time in Chicago

    Check out division street or the magnificent mile for a good time. Both can be reached with the subway system (a little sketchy and about 30min travel time) Mid week the magnificent mile is a...
  6. Replies
    12
    Views
    644

    At the same time its an exclusive market, not...

    At the same time its an exclusive market, not many techs know how to service ult's. Haven't worked on a cryo unit yet, but they're becoming more prevalent with stem cell research heating up. FYI if...
  7. Replies
    12
    Views
    644

    Email Address

    Hey 94blowncobra, whats your email adress?
  8. Replies
    2
    Views
    355

    Medical Refrigeration Dealers Wanted

    Please read the forum rules, if you want to advertise here, you must purchase an ad.
  9. Replies
    22
    Views
    5,128

    Therm58

    Hey therm76, the cold headers you're talking about, look at the diameter of the tap that comes out. The new ones are wider at the back of the tap and have a rolled connection, thats the only...
  10. Replies
    22
    Views
    5,128

    There biggest failure we have with these boards...

    There biggest failure we have with these boards is that they will indicate that the pressure switch is closed b4 start up or that there is an issue with the ignitor. There are no issues with the...
  11. Replies
    10
    Views
    1,191

    The unit will go into defrost every 34 min if...

    The unit will go into defrost every 34 min if there is no ice sensed on the coil. If ice is sensed on the coil it will immediately go into defrost. The way the defrost shuts off is by sensing the...
  12. Replies
    22
    Views
    5,128

    Must be an installer

    Ya our installer have put in tons of G51 as well and never seen a board failure. The reason they've never seen one is because us service guys are the ones going buy finding the problems. I have...
  13. Replies
    22
    Views
    5,128

    Lets cross our fingers!

    I've changed so many of the newer G51 surelight boards its not funny. Everytime I go to the lennox warehouse there's a huge pile of returned boards. Hopefully their new-04 series has corrected all...
  14. Replies
    4
    Views
    674

    It turned out that the valve that I changed was...

    It turned out that the valve that I changed was also a dud. Quality!
  15. Thanks, will do.

    Thanks, will do.
  16. Keeprite pressure switch hose filling with water, why?

    Hey everyone, Im a hvac/r tec and i have a bit of a head scratcher. Im working on a mid efficiency keeprite. The pressure switch hose is filling up with water every few days. I think the issue is...
  17. Cheap Chinese Motors

    Just installed one last night, noticed that Goodman is still using the crapy chinese motos. They had a bad bunch of them 2 years ago. I still like the Lennox equpiment the most however is some is...
  18. Replies
    22
    Views
    5,128

    Ya I attended the G71 seminar about two months...

    Ya I attended the G71 seminar about two months ago and its was really intresting. Question is, will this new system really offer that much more benifit compared to the G61.

    About the lining in...
  19. Replies
    22
    Views
    5,128

    1

    1
  20. Goodman AC's have changed a bit

    I've noticed that the goodman ac's are not using the parker service valves anymore. I perfer the Parker valves over these generic valves only because alot of installers are not reading the...
  21. Replies
    22
    Views
    5,128

    Problems with Lennox G51

    Hi there everyone I work for a lennox dealer and I thought I would fill you in on some of the issues we've had with the Lennox G51.
    Well let me start with propane aplications. Depending on the...
  22. Thread: Chinese ULT

    by fd3687
    Replies
    29
    Views
    2,900

    Its sucks

    It really pisses me off that this is the situation. I always thought that the governments elected were supposed to represent the people. I would think that the majority of the people would want...
  23. Thread: Chinese ULT

    by fd3687
    Replies
    29
    Views
    2,900

    Let me rephrase this. Americans should have...

    Let me rephrase this. Americans should have acess to FREE BASIC HEALTH CARE. If France, Italy, England, Germany, Canada and Spain can offer FREE BASIC HEALTH CARE to its citizens then I see no...
  24. Thread: Chinese ULT

    by fd3687
    Replies
    29
    Views
    2,900

    Human Rights

    Human rights is a big issue that I need to adress. Everyone condems China about their policies on human rights. They are slowly making changes to improve this issue but they have a long way to go. ...
  25. Thread: Chinese ULT

    by fd3687
    Replies
    29
    Views
    2,900

    Big Change!

    We've tested these units for three months and I'm extremely happy to report that these units are of excellent quality and have out performed our Sanyo test unit. We find that the accuracy of our...