  1. Replies
    7
    Views
    394

    Installation is everything. A properly installed...

    Installation is everything. A properly installed system that has the correct airflow should and will most likely give many years of good service. As far as replacement parts, and availability, it...
  2. Replies
    3,304
    Views
    127,086

    never stops amazing me at the amount of people...

    never stops amazing me at the amount of people who believe that taking guns out of the hands of good guys will somehow cause the bad guys to stop using their guns. How can anyone honestly believe...
  3. Replies
    19
    Views
    1,230

    Charging a unit based on pressures is not the...

    Charging a unit based on pressures is not the thing to do.
  4. Replies
    51
    Views
    2,579

    It is true that you can read different...

    It is true that you can read different publications that will give different rules for changing out caps. I too have read information that will say you can go up but not down, some say 10 percent up...
  5. Replies
    11
    Views
    631

    A wise friend told me one time that you can't be...

    A wise friend told me one time that you can't be the best and the cheapest. I do everything for a reasonable rate, and do the best I can at it. I try to be professional and efficient. But my time,...
  6. I had a compressor one time that would trip the...

    I had a compressor one time that would trip the breaker and I would get called out. By the time I got there, the compressor was cooled down and would check out fine in every way. I would reset the...
  7. Replies
    5
    Views
    320

    A heat pump unlike a regular a/c operates at very...

    A heat pump unlike a regular a/c operates at very low out door air temperatures. during low ambient temperatures, the refrigerant in the system will tend to migrate to the lower temperatures of the...
  8. Thread: TXV Question

    by surenuff
    Replies
    11
    Views
    817

    I have seen txv's leak through the external...

    I have seen txv's leak through the external equalizing tube before. But if it is leaking through the external equalizing tube, then the valve itself will not be able to control this in anyway...
  9. I do not know of any factory training, but I am...

    I do not know of any factory training, but I am sure they have it. I have worked a lot on these different ice cream machines and I find that if you have a pretty good background in refrigeration and...
  10. Replies
    3,304
    Views
    127,086

    In every conversation we all could have over any...

    In every conversation we all could have over any subject matter you want to discuss, it is always the liberal minded folks that get out of control and start being hateful and mean. These are the...
  11. Thread: Low coolant?

    by surenuff
    Replies
    7
    Views
    408

    I guess now that I would like to have them...

    I guess now that I would like to have them explain to me how a "bad" compressor is capable of icing up the evaporator. Now it is very possible when a unit is icing up, particularly because of low...
  12. Replies
    24
    Views
    1,854

    yea, when you have to clean condenser coils that...

    yea, when you have to clean condenser coils that are full of the stuff, you end up pouring on way more cleaner than you need just to help get rid of the smell.
  13. Great idea!!!!!!

    Great idea!!!!!!
  14. Replies
    3
    Views
    278

    during that 30 seconds of run time (which is...

    during that 30 seconds of run time (which is longer than it may seem for making observations) is the suction vapor line cooling down, and does the out door fan seem to be moving warm air or is it...
  15. no, do NOT tear it off. IF it has been there all...

    no, do NOT tear it off. IF it has been there all along then this is not your problem. Tearing it off will cause a new problem you will have to deal with. Condensation all over the outside of it. ...
  16. Replies
    51
    Views
    2,579

    As I said earlier, I too carry a 1/4 of a rat...

    As I said earlier, I too carry a 1/4 of a rat pack full of nothing but capacitors from small to large and single to duals. No one (at least not me) has advocated using anything but the correct...
  17. I have used this several times and never went...

    I have used this several times and never went back on a leak where I used it. These are made by a company called Swadge-Locke and they work great. I first used one on a trane where the copper and...
  18. Replies
    24
    Views
    1,854

    Had to work on a many of unit covered in S$=t. I...

    Had to work on a many of unit covered in S$=t. I hate those critters with all my heart. They destroy a lot of equipment.
  19. Replies
    7
    Views
    292

    It could be reversing valve not fully seating one...

    It could be reversing valve not fully seating one way or the other, or bad valves in compressor, or as stated, a low refrigerant charge caused by a leak could also cause it to not shift properly. ...
  20. Replies
    34
    Views
    1,606

    You said that both fans are running, but do you...

    You said that both fans are running, but do you here the compressor itself running. without it we are not going to cool.
  21. Replies
    3
    Views
    278

    Is the outside fan running when the unit starts...

    Is the outside fan running when the unit starts in cooling mode? What other things have you noticed about this system when it comes on?
  22. is it a "groaning" or more of a higher pitched...

    is it a "groaning" or more of a higher pitched harmonic/ringing sound? I have came across several variable speed blowers now that have had this "harmonic" issue.
  23. I will try to look up these numbers and do some...

    I will try to look up these numbers and do some more thinking on it. But right off the bat, here is the deal. There was an article I read awhile back that was titles 13 seer + 10 seer = 8 seer. In...
  24. Can't wait to hear the outcome on this one. Very...

    Can't wait to hear the outcome on this one. Very interesting problem. I wonder what the chances are that some of the manufacturing materials on the new furnace could be causing this. I heard a...
  25. You are correct. I live in west Texas myself...

    You are correct. I live in west Texas myself where the temps stay up around the century mark most of the summer, and I have done a lot of load calcs for my area. Just going out on a limb here, but...